Have been able to reproduce this using the attached config files. Run up
openHAB and navigate to the classic UI. Turn on TestA1, then turn on TestB1,
then turn off TestA1 and finally turn off TestB1.
You should see the initial ON events in each log file, but then the off events
for both switches appear in the B log.
Original comment by ben.jone...@gmail.com
on 24 Jul 2013 at 10:13
Attachments:
Ok - have pushed a change to my clone which I think should resolve this issue.
There was a single encoder being used for all logging appenders. However as
each appender is initialised each one calls .start() which opens the output
file stream and initialised the encoder with this stream. Therefore the last
appender loaded becomes the output stream for all previous appenders!
My fix was to create a new encoder for each appender. Please review and merge
with core if you think it is ok.
Original comment by ben.jone...@gmail.com
on 24 Jul 2013 at 11:28
Hi Ben, thanks for investigating this and for the fix.
Original comment by teichsta
on 25 Jul 2013 at 7:33
Merged to default (see
http://code.google.com/p/openhab/source/detail?r=5761df62eea2c0a35695cfab2eaa16a
13ad51b43)!
Thanks Ben, for this contribution!
Original comment by teichsta
on 25 Jul 2013 at 10:59
Original issue reported on code.google.com by
ben.jone...@gmail.com