saleae / simple-parallel-analyzer

Saleae Simple Parallel Analyzer
MIT License
7 stars 7 forks source link

Rising edge trigger doesn't work properly #11

Open tgtakaoka opened 1 year ago

tgtakaoka commented 1 year ago

Logic version: 2.4.6

The rising edge trigger of Simple Parallel anayzer doesn't work as expected (see screenshot).

It samples data (AD0~7) at falling edge of trigger signal (#RD and #WR), and the UI shows rising arrow mark on falling edge.

image

tgtakaoka commented 1 year ago

Probably fixed by dc343bca72d213c2b3b4754660cea35ef9a295f5, waiting for the fix is published via Logic update.

timreyes commented 1 year ago

Yes, sorry for the bug! We plan on implementing the fix in the next release of the Logic 2 software (2.4.7).