I have a EEG data sample which contains six channels. Two of them are scalp channels (Tp9 & Tp10), the other four are implanted electrodes which are located near the medial geniculate nucleus (MGB) of the patients brain during deep brain stimulation (DBS) surgery. The exact location is not known, but these four channels are only millimeters apart in order to extract accurate local field potentials (LFP). I added the EEG data as EDF file and the channel locations as LOC file. When I try to run ASR with the following code for example, I receive an error saying:
Output-->
'Array indices must be positive integers or logical values.
occurred in:
clean_windows: 105
clean_asr: 146
clean_artifacts: 233
pop_clean_rawdata: 151'
or
'Integers can only be combined with integers of the same class, or scalar doubles.'
I tried to convert the EEG.data to double in order to make positive integers or integers, but this does not seem to work.
I cannot go into the detailed functions to check where it goes wrong.
Can you please help me out?
I have a EEG data sample which contains six channels. Two of them are scalp channels (Tp9 & Tp10), the other four are implanted electrodes which are located near the medial geniculate nucleus (MGB) of the patients brain during deep brain stimulation (DBS) surgery. The exact location is not known, but these four channels are only millimeters apart in order to extract accurate local field potentials (LFP). I added the EEG data as EDF file and the channel locations as LOC file. When I try to run ASR with the following code for example, I receive an error saying:
Input --> EEG = eeg_checkset( EEG ); EEG = pop_clean_rawdata(EEG, 'FlatlineCriterion','off','ChannelCriterion','off','LineNoiseCriterion','off','Highpass','off','BurstCriterion',20,'WindowCriterion',0.25,'BurstRejection','on','Distance','Euclidian','WindowCriterionTolerances',[-Inf 7] ); [ALLEEG EEG CURRENTSET] = pop_newset(ALLEEG, EEG, 1,'overwrite','on','gui','off');
Output--> 'Array indices must be positive integers or logical values. occurred in: clean_windows: 105 clean_asr: 146 clean_artifacts: 233 pop_clean_rawdata: 151'
or
'Integers can only be combined with integers of the same class, or scalar doubles.'
I tried to convert the EEG.data to double in order to make positive integers or integers, but this does not seem to work. I cannot go into the detailed functions to check where it goes wrong. Can you please help me out?
Thank you in advance, AD stimulus AD elektrodes.zip
Sincerely, Jelle van der Eerden