Recoding of a non-hierarchical variable not working properly #264

Open borisfrenkie opened 11 months ago

borisfrenkie commented 11 months ago

Please specify
SDC tool used: tau-argus Version used: 4.2.4 Build 2 Operating system used: Windows


Hi,

in a most recent version of tau-argus recoding of a non-hierarchical variable is not working properly.

In the example I'm using some microdata and creating a 2D table with some sensitivity rules setting.

fig1

Then, when trying to recode the "SIET" variable, the whole tau-argus crashes.

fig2

I also tried the same procedure in the older version of tau-argus (4.2.0 Build 5) and everything worked fine.

Attached are the files.

example.zip

Best,

Boris

ppdewolf commented 11 months ago

Hi Boris, I do not know why yet, but a workaround that works for me, is to specify missing-codes for the spanning variables: afbeelding

borisfrenkie commented 11 months ago

Hi Peter-Paul,

that helped, thank you :-)

ppdewolf commented 11 months ago

But it should be working without specifying a missing code as well, so I'll add it to the bug-list. Thanks for spotting this.