Closed claudioasn closed 6 months ago
Hello, the procedure for L1C is the same as L2A. Please enable "Records detailed events in a log file" and copy the log file as described here https://semiautomaticclassificationmanual.readthedocs.io/en/latest/faq.html#how-can-i-report-an-error
Hi @semiautomaticgit, I have the latest LTR QGIS and all dependencies installed and updated. Here is what I tried:
ERROR|2024-05-09T18:26:14.299|preprocess_products|perform_preprocess|573|unable to process files
I tried many things, but nothing works in L2A data.
I appreciate your help on this.
Hello @claudioasn, the Image conversion tool requires that all the bands are in the same directory. You should move all the .jp2 files inside the same directory and rename the files with the band number in the ending of the name (e.g. from name_02_10m.jp2 to name_02.jp2) Then select this directory in Image conversion. Images are converted to reflectance.
I try to preprocess Sentinel-2 L2a images with the image conversion tool. When i the directory containing bands and select the metadata, nothing happens. No band is load on the table. To check, i tried to process the same scene with L1C, and it worked fine. Is there a different workflow for processing L2A images?