seto77 / ReciPro

The software ReciPro makes various crystallographic calculations, visualizes a crystal structure, simulates a diffraction pattern and high-resolution TEM image, indexes diffraction spots, plots stereographic projection, and so on.
https://seto77.github.io/ReciPro/
Other
113 stars 13 forks source link

SpotID v1 (zone axis) #27

Open yoshiA3 opened 8 months ago

yoshiA3 commented 8 months ago

Thank you Dr. Sato for producing ReciPro which is very useful software for me. The zone axis was outupted as [00-1] (please find an attaced file). This means that the c-axis direction is under the screan (left-handed system). Is it correct? 2023-12-20083714

seto77 commented 8 months ago

The answer to your question is almost yes. The direction of the zone axis is toward the back of the screen. However, the coordinate system in ReciPro is right-handed.

By double-clicking on the output crystal axis, you can change the crystal orientation. Please give it a try.

yoshiA3 commented 8 months ago

Thank you for your reply. I was able to check the crystal orientation by double-clicking on the output. Thank you.