Handle baud rate change for CSR modules #377

Open GoogleCodeExporter opened 9 years ago

GoogleCodeExporter commented 9 years ago
I am using r2351 , file hci.c , line 871 has a problem

if (hci_stack->substate > 1 || COMMAND_COMPLETE_EVENT(packet, hci_reset))

Notice that a OR is used, shouldn't that be an AND? Isn't there a risk of the 
next command being sent before the unit has fully reset?

I am seeing this problem right now, monitoring my UART using an logic analyzer. 
The command complete does not arrive before the subsequent command

Original issue reported on code.google.com by frank.zhao.main@gmail.com on 5 Feb 2014 at 3:43

GoogleCodeExporter commented 9 years ago
ok the problem is very complex, it's not a battle between OR or AND, it's the 
substate number that's the problem. The problem is that if a new baud rate does 
not need to be adjusted, the substate skips to 4 immediately, which skips 
waiting for the reset to complete

To fix this, a change needs to be added to hci_run's substate-machine's 
switch-case

I have attached a tested patch

Original comment by frank.zhao.main@gmail.com on 5 Feb 2014 at 6:55

Attachments:

GoogleCodeExporter commented 9 years ago
hmm... this presents a problem, the patch I submitted only solves the problem 
if the user does not wish to change the baud rate.

According to BCCMD documentation, the command complete reply to the change baud 
rate command will be returned at the new baud rate. But the BTstack code does 
not advance to changing the host baud rate until a command complete is received.

Also, it is highly likely that the UART transmitter is FIFO'ed and there's a 
good chance that the baud rate can be changed in the middle of a packet if the 
coder isn't careful enough about waiting for the FIFO to be drained first. (On 
embedded, this is easy to detect, I'm not sure about other platforms.)

This means that there is a VERY small timing window when the host baud rate can 
be changed, immediately after the last byte in the FIFO is sent completely, but 
before the controller can reply.

For BlueCore chips, a simple fix is to simply move the set_baud function right 
after the hci_send_cmd_packet. However, I have no idea how TI brand chips 
handles a baud change request.

Original comment by frank.zhao.main@gmail.com on 5 Feb 2014 at 8:27

GoogleCodeExporter commented 9 years ago
baud rate change: at least for the modules I've worked with, the module will 
send the command compete with the old baud rate before changing to the new one. 
Otherwise, it would be impossible for the module to report an unsupported baud 
rate (as the host would already switch to the unsupported baud rate). In 
practice, I don't see a reason to change the baud rate after the initial 
startup, and there, the Bluetooth module isn't supported to send anything.

I'll look at the "wait for reset complete" later, but that clearly makes sense. 
(that HCI startup is more or less the oldest code in BTstack and I don't really 
like the ugly substate management with the extra cases).

Original comment by matthias.ringwald@gmail.com on 6 Feb 2014 at 1:10

GoogleCodeExporter commented 9 years ago
For BlueCore, one way is to edit the UART setting in the persistent storage, 
but I want to avoid that. The second way is through BCCMD.

BCCMD command reference clearly states "This BCCMD command immediately 
configures the UART’s baud rate and settings. The GETRESP for this command 
will probably return to the host at the new UART settings."

Although your state machine will not be able to handle this because it is not a 
"command complete", I'll have to hack around that.

My RN42HCI starts up at 115200 baud by default, I'd like to keep it that way, 
and only make temporary baud rate changes, not permanent.

The developer should be responsible for making sure that the baud rate is 
supported.

Original comment by frank.zhao.main@gmail.com on 6 Feb 2014 at 3:04

GoogleCodeExporter commented 9 years ago
Could you send me the docs for that (I've seen them before but don't have them 
with me). While I'd argue that changing it after the command complete would 
make sense, we need a solution if CSR does change it before that.

Also.. "|command will probably return to the host at the new UART settings" is 
a bit unclear at least. Does it or does it not use the new setting. :) Did you 
see it on the logic analzyser?

So, if CSR indeed needs that, I'd suggest to add a configuration flag to the 
hci_uart_config_t that specifies if the UART speed is changed before or after 
the command complete.

In general, that's clear flaw of the Bluetooth specification to not define 
this. It wouldn't have been so hard to do so.

Original comment by matthias.ringwald@gmail.com on 6 Feb 2014 at 6:16

GoogleCodeExporter commented 9 years ago
(changing topic as wait for reset to complete has been rewritten and works with 
CSR8811)

Original comment by matthias.ringwald@gmail.com on 30 Jul 2014 at 12:35