zhihongp commented 1 year ago

Regarding Fig. 8b, could you help clarify details about the validation dataset? Using the released SAE_SPN, I used 500 randomly cropped 512x512 patches from Cityscapes validation images (leftImg8bit) but the FID is around 128.

zhihongp commented 1 year ago

I forgot hist_equal() initially, after correction, it's 115.96 16.77 0.518 0.768 for FID, PSNR, SSIM and FSIM respectively, still worse than reported metrics in the paper