Closed gkasprow closed 4 years ago
can the VOCM be left dangling?
VOCM for the ADA4927s needs to be tied to ground.
VOCM for the ADA4927s needs to be tied to ground.
Done
There are FB connected to the supply pins. Aren't there missing decouplig caps?
Added according to datasheet: 1nF 100nF ceramic and 10uF tantalum capacitors for each supply.
Added according to datasheet: 1nF 100nF ceramic and 10uF tantalum capacitors for each supply.
Please make notations for voltage and dielectric spec (X7R or NP0) for the ceramic caps. These amps may be driving a reasonable amount of current into the terminated transmission lines and so we want to make sure we don't have dc bias issues with the capacitors.
it's not relevant anymore. we don't have any caps in the signal path in the FMC project. I added a note on the AFE schematics
There are FB connected to the supply pins. Aren't there missing decouplig caps?