J1, J10 wrong PNs in BOM #92

Closed pkozakiewicz closed 3 years ago

pkozakiewicz commented 3 years ago

Correct PNs are given in LibRef column.

gkasprow commented 3 years ago

right, it should be ESW-117-23-L-D

gkasprow commented 3 years ago

and ESW-113-23-L-D

gkasprow commented 3 years ago

It's clear now. ESW-117-33-L-D-ND should be used with the original 3M connectors. They have 16.13 mm height; they need to be assembled in an elevated way ESW-117-23-L-D should be used with IDC replacement connectors. They have a 13.59 mm height so will match the replacement connectors.

gkasprow commented 3 years ago

@pkozakiewicz I drafted a new release

pkozakiewicz commented 3 years ago

@gkasprow Ok I'm launching the production now.