sinara-hw / Thermostat

2-channel temperature controller
5 stars 3 forks source link

extra EMI capacitors #60

Closed hartytp closed 5 years ago

hartytp commented 5 years ago

To avoid any rectification by the EMI diodes, let's add extra EMI capacitors like this:

image

gkasprow commented 5 years ago

shouldn't they be added to GND? Otherwise large CM signal can still be rectified.

hartytp commented 5 years ago

Yep you’re right. Add a larger dm cap as well to avoid cm to dm conversion (or copy the caps from the rfi filter to make it two stage)

gkasprow commented 5 years ago

Can we stick with such design? obraz