Allow EEM/Molex/Barrel 12V to be measured with the shunt #18

Closed jordens closed 3 years ago

jordens commented 3 years ago

These should drive P12V0_R

image

jordens commented 3 years ago

And the EEM (by default) as well.

image

That makes FORCE_EEM_Source meaningful as it force-overrides the current measurement as well.

gkasprow commented 3 years ago

obraz obraz obraz

The only issue is that the load connected to EEM is not measured. What we can do is to add yet another FET that would redirect the current when powering downstream port obraz

jordens commented 3 years ago

I don't think that's necessary. But I'll leave it to you.

gkasprow commented 3 years ago

let's keep it simple then.