deckblad commented 9 years ago

In SPH or "mirrored" symmetry with one part mirrored to both sides, especially rotatrons. Set one side to "inverse" so they both move the same way. If you right-click a rotatron after setting unique min/max values via the main "grouping" GUI, the values of one immediately overwrite the min/max values on the other side.

I'm guessing the values on both refresh when the right-click GUI is drawn. I suggest not updating those values unless the UI sliders are moved

sirkut commented 9 years ago

Due to limitations of KSP and how symmetry mode is handled while in the VAB/SPH versus Flight I'm going to accept defeat and close this one. if you wish to store individual values across items that are placed symmetrically I suggest using a mod like PartWizard. http://forum.kerbalspaceprogram.com/threads/80124-0-23-5-Part-Wizard-(1-1-0)-6-Jun-2014