Closed sakrlog closed 2 months ago
Hi You can also disable the webserver and see it that helps. It might be a good idea to disable by default
# Enable webserver
#web_server:
# port: 80
Sorry I cant help you with that error but perhaps check that all your fuses and circuit breakers are still good
Hey, first thanks so much for the awesome work!
So I have modified the code a little bit because my nodeMCU kept on booting every ~40 mins. I figured that this could be because of the large code. And this turned out to be true. I'm using ai-thinker esp32 nodeMCU V1. This turned out to be true. So I have my updated code in updated.txt file attached here.
So everything seems to be fine except when I toggle Generator Charge button. The inverter cut out the power to all ports and threw this error: F26BusUnbalance_Fault.
I was in off-grid mode with my backup generator turned on. updated.TXT