Open GoogleCodeExporter opened 9 years ago
Search after interval in the source and change it from 13 days to 11 (there are
two lines containing interval = 13 days which should be changed as I can
remember) and compile again - then it should work.
Original comment by christop...@googlemail.com
on 23 May 2012 at 3:19
If i give this URL to my browser i get:
Bad request 400: Power value [7272] too high for system size [4760]
If your System is realy only 4760 in Size, the value 7272 is bad!
So this is a Problem i have with 5000TL-21 too. Many times a day i get database
entries which are to high and then the upload to pvoutput.org will fail.
As a workaround go into your database and search for entries which are looking
bad.
For example use:
select * from DayData where CurrentPower>0;
When you find entries which are wrong (And i think you will) then delete dem
with something like:
delete from DayData where CurrentPower>5000;
and
delete from DayData WHERE DateTime LIKE "1970-%%-%% %%:%%:%%";
I often have entries with 0 Seconds since 1970.
Greetings
Mario
Original comment by janus44...@gmail.com
on 23 May 2012 at 9:40
SOLVED some database entries were too high.
GERAT
Many Thanks to Mario
Original comment by gaetano.perrotta@gmail.com
on 24 May 2012 at 10:53
Original issue reported on code.google.com by
gaetano.perrotta@gmail.com
on 23 May 2012 at 10:56