softwarecrash / Daly2MQTT

ESP8266 Connector to get Daly / XENES / HI-BMS / BullTron BMS Data into MQTT systems
Other
146 stars 31 forks source link

SOC is set to the status of Pack_SOC after a reboot! #169

Closed AlfredSch closed 5 months ago

AlfredSch commented 5 months ago

Is there an existing issue for this?

Used Hardware?

Wemos D1 Mini

What happened?

Hello, I am using Daly2Mqtt in conjunction with IoBroker. My problem is that when the Daly2Mqtt reboots or logs into the W-Lan again, it automatically writes the SoC of the BMS with the value that was last set in the IoBroker ( Pack_SOC ). How can I prevent this so that the Pack_SOC is only written when I want it to be. Greetings & thanks Fred

Screenshots / Fotos

no

Steps To Reproduce

Hello, I am using Daly2Mqtt in conjunction with IoBroker. My problem is that when the Daly2Mqtt reboots or logs into the W-Lan again, it automatically writes the SoC of the BMS with the value that was last set in the IoBroker ( Pack_SOC ). How can I prevent this so that the Pack_SOC is only written when I want it to be.

Version

2.x.x and above

Relevant livejson output

no

Which BMS is connected?

Daly BMS LIFEPO4 16S 48V UART

What browsers are you seeing the problem on?

Chrome

softwarecrash commented 5 months ago

hello, please try to set the settings of the mqtt server to this image

AlfredSch commented 5 months ago

Hello and thanks for the quick reply :-) I have seen today that there is an update, with this version the error is gone. I have also adjusted the setting of the MQTT instance Greetings Fred