SMA SunnyIsland Bridge - Battery Under voltage errors - URGENT #42

Closed Kyle-Swanepoel closed 3 years ago

Kyle-Swanepoel commented 3 years ago

Hi team,

We have an issue with SMA SunnyIsland bridge on the loggers. Ping to the SI is missing and causing a discrepancy between the data we are sending and the data we are receiving from the SI. We have an increase in the number of support calls for batteries over or under discharging.

A reboot of the logger temporarily fixes the issue, but the ping soon disappears. It seems that some of the sites are even working on Lead Acid Emulation, but this was not a change made by us.

image image image

LeonidasHanos-debug commented 3 years ago

Hi team,

The main issue is that the SI are going into a fault state due to battery under/over voltage errors, there are no corresponding errors on mypower24.

There currently are 3 x sites that are reporting the same issue.

SLV200956309 - Bridging technology SLV201502890 - Kobus SLV209980540 - Material boards main SLV210690625 - Material boards extension cluster SLV212286807 - Leonhard Eins  SLV210010492 - Leonhard Eins SLV207265502 - Leonhard Eins

image

Masud-Sonday commented 3 years ago

Ping missing fixed in version 7.1241 logger update.

Kyle-Swanepoel commented 3 years ago

@Masud-Sonday Hi Mas,

We have clients reporting daily that their SMA sites are switching off due to Battery under voltage readings on SI. There are still problems with Nkau, please see excerpt from Sunny Portal.

image

Further issues on this off grid site: (Access has been granted on portal - Plaas Krige) image Waiting on 2nd logger to update to 7.1241 WhatsApp Image 2021-01-27 at 21 43 42 WhatsApp Image 2021-01-27 at 21 43 28 WhatsApp Image 2021-01-27 at 21 38 59

At the moment, logger soft reboot is still switching the SI off on most sites.

Masud-Sonday commented 3 years ago

@Kyle-Swanepoel Sunny island issues fixed in logger update version: 7.191