This is a proposed enhancement to expose some refrigerated case and walk-in input parameters in Grocery prototype, so that refrigerated cases and some related systems can be controlled via input parameters.
Incorporates PR #43
Moved default values from insert to import statements, except parameters that will not change (e.g. case_name)
Please comment if you see a need to expose other parameters from these systems.
Created new parameters credit_sch and available for refrigerated cases (ref-case)
credit_sch intended to account for presence or lack of night covers, and minor calibration of case credit
available intended to narrow the scope of refrigeration end-use consumption to refrigerated cases subject to a measure (by turning off other refrigerated cases through their availability schedule)
As well as refrigerated cases, we exposed a few parameters from ref-sys.
We grouped together the input parameters for both MT and LT systems, under one prefix refsys. Please comment if you see a need for separate params for MT and LT systems.
Created new parameter condenser_type for ref-sys.
PR Author
[x] Make sure the PR branch is up to date with main branch at the time of the PR submission
[x] Craft a succinct title that effectively encapsulates the essence of the pull request, providing a general overview of the proposed changes.
[x] Label the PR with at least one of the following: New Measure, Bug, or Feature.
[x] Provide a concise description of the measure, bug, or feature. Submit one PR per measure.
N/A - For a new measure, attach a workbook named DEER_EnergyPlus_Modelkit_Measure_list_working.xlsx, containing only rows used for post-processing the measure.
[x] Add comments in the code when necessary to facilitate the review process.
[x] Add a comment before the added code, including the author's full name, company, and specifying if it's a bug fix, new measure, or feature.
N/A - For a new feature or bug, demonstrate the impact on energy consumption for selected cases with justification using plots and descriptions.
N/A - For a new measure, add a summary table showing total energy consumption per simulated case.
PR Reviewer
[ ] Conduct a thorough code review.
[ ] If the branch is behind the main, merge the branch locally to check for potential conflicts.
[ ] If a bug, locally reproduce it and compare energy consumptions before and after.
[ ] Explore creative ways to stress-test the code.
[ ] Locally check the error file and other outputs.
Pull Request (PR) Description
This is a proposed enhancement to expose some refrigerated case and walk-in input parameters in Grocery prototype, so that refrigerated cases and some related systems can be controlled via input parameters.
case_name
)credit_sch
andavailable
for refrigerated cases (ref-case)credit_sch
intended to account for presence or lack of night covers, and minor calibration of case creditavailable
intended to narrow the scope of refrigeration end-use consumption to refrigerated cases subject to a measure (by turning off other refrigerated cases through their availability schedule)refsys
. Please comment if you see a need for separate params for MT and LT systems.condenser_type
for ref-sys.PR Author
PR Reviewer