Changes to water heater template in anticipation of simulations for SWWH014 and SWWH025 for HPWH and WPWH fuel switching, as well as future 120v HPWH measures.
water-heater.pxt:
HPWH thermostat height was below the top of the coil, resulting in tank overheating and heat being vented from the tank (due to stratification). Moved sensor height to the top of the coil.
Parameterized water usage temperature.
Added a target water usage temperature to the WaterUse:Equipment and WaterUse:Connection objects and parameterized the setpoint.
Added curves for 120v plug-in HPWH developed by AWHI/NBI
Changed Coil:WaterHeating:AirToWaterHeatPump:Wrapped rated condenser water temperature to match the loop temperature, which is used to calculate the rated COP.
Parameterized tank_element_control_logic and changed the default to "Simultaneous" instead of "MutuallyExclusive". Our market research has found most hybrid HPWH allow simultaneous operation.
[x ] Make sure the PR branch is up to date with main branch at the time of the PR submission
[x ] Craft a succinct title that effectively encapsulates the essence of the pull request, providing a general overview of the proposed changes.
[x ] Label the PR with at least one of the following: New Measure, Bug, or Feature.
[x ] Provide a concise description of the measure, bug, or feature. Submit one PR per measure.
[x ] For a new measure, attach a workbook named DEER_EnergyPlus_Modelkit_Measure_list_working.xlsx, containing only rows used for post-processing the measure.
[x ] Add comments in the code when necessary to facilitate the review process.
[x ] Add a comment before the added code, including the author's full name, company, and specifying if it's a bug fix, new measure, or feature.
[x ] For a new feature or bug, demonstrate the impact on energy consumption for selected cases with justification using plots and descriptions.
[x ] For a new measure, add a summary table showing total energy consumption per simulated case.
PR Reviewer
[ ] Conduct a thorough code review.
[ ] If the branch is behind the main, merge the branch locally to check for potential conflicts.
[ ] If a bug, locally reproduce it and compare energy consumptions before and after.
[ ] Explore creative ways to stress-test the code.
[ ] Locally check the error file and other outputs.
Pull Request (PR) Description
TRC
Changes to water heater template in anticipation of simulations for SWWH014 and SWWH025 for HPWH and WPWH fuel switching, as well as future 120v HPWH measures.
water-heater.pxt:
root.pxt:
Energy consumption: Before results-summary.csv After results-summary.csv
HPWH annual COP changed from approx. 1.4 to 2.4.
PR Author
PR Reviewer