The down looking camera "Find Target" button is not working for automated recognition of fiducial marks.
Going into the hidden menu and performing a Vision Set calibration on the down-looking camera while looking at a 1mm round fid seems to work once you setup the threshold to about 85 and the Rsize to 30,30. you must be in Binary image to see it.
The problems I can see are:
1- these new values are not saved
2- the PCB calibration "Find Target" still does not work after performing this calibration
Thanks for reporting! As mentioned on the mailing list, we don't control the software so we can't fix this. I hope OpenPNP can be an option in the near future.
The down looking camera "Find Target" button is not working for automated recognition of fiducial marks. Going into the hidden menu and performing a Vision Set calibration on the down-looking camera while looking at a 1mm round fid seems to work once you setup the threshold to about 85 and the Rsize to 30,30. you must be in Binary image to see it.
The problems I can see are: 1- these new values are not saved 2- the PCB calibration "Find Target" still does not work after performing this calibration