Closed saffari101 closed 2 years ago
Hi saffari101,
You would just use -4 instead of 4.
With the finite field method no gap is needed. You should be able to reuse the data file from the slab method without change. See the relevant Dufils paper cited in the main description -- no gap is introduced, which makes the method far more efficient.
thanks a lot for your help dear Shern!
Hi Shern
I want to reverse the electrodes' potentials. If left electrode has -2 V and right electrode 2 V according to script below, what would be if I want to reverse it as left electrode to be 2 V and right electrode to be -2 V,
Also, since in ffiled we use p p p boundary, how much gap distance is required to put in the end of simulation box in z direction, right behind the electrodes, in order to halt the interactions of ions and electrodes with image atoms from the z direction in the next periodic simulation box?
Bests,