Missing valueQuantity in component #14

Closed markkramerus closed 6 years ago

markkramerus commented 6 years ago

See the IG page for HER2ReceptorStatusISH: http://build.fhir.org/ig/HL7/us-breastcancer/StructureDefinition-oncology-HER2byISH.html)

In the profile, valueQuantity is missing from the profile in two of the components (AverageHER2SignalsPerCell and AverageCEP17SignalsPerCell)

Note: this is the same bug as HIGH PRIORITY: Observation Components in profile are missing valueQuantity #75 in shr-cli, but I copied it here because it needs to be fixed for the ballot.

That bug has a picture :)

cmoesel commented 6 years ago

Seems like when we apply a constraint on the Quantity, it shows up. But if we don't... gone! Will debug it.

cmoesel commented 6 years ago

Fixed. See the standardhealth/shr-cli#75 for the screenshot.