Closed staneuski closed 4 years ago
Environment | Parameter |
---|---|
Compiled using OpenFOAM | dev-48a3622 |
Product Version | v0.4.4-alpha |
Commit | 26d6176 |
Case \ File | tube/ |
Comments | Check the results for inlet constant velocity 400 [m/s] when inlet temperature is 332 [K] and outlet temperature is 769.3 [K] |
Standard OpenFOAM shockTube/ case and setup. Comparison between multiCompressionFoam (v0.4.4-alpha), rhoCentralFoam and rhoPimpleFoam.
[ commit ed52d29 ]