stante / the-bus-pirate

Automatically exported from code.google.com/p/the-bus-pirate
Other
0 stars 1 forks source link

Supplies power locks 'on' after SPI writes, mode switch #52

Closed GoogleCodeExporter closed 8 years ago

GoogleCodeExporter commented 8 years ago
What steps will reproduce the problem?
1. Switch to SPI mode
2. Activate supplies
3. Write command
4. Without disabling supplies, switch to HiZ mode. Note that supplies turn off.
5. Switch back to SPI mode. Note that supplies switch on without being 
requested to.
6. Attempt turning off supplies (w). Note that supplies DO NOT turn off.

What is the expected output? What do you see instead?
Supplies to turn off following any mode switch. Supplies to always obey W/w 
commands. Instead, supplies become unresponsive except to reset (#).

What version of the product are you using? On what operating system?
5.1 r402. Windows 7 64-bit via PuTTY.

Please provide any additional information below.
This behavior also occurs with 5.0 r382

Original issue reported on code.google.com by dan.be...@gmail.com on 5 Jul 2010 at 4:52

Attachments:

GoogleCodeExporter commented 8 years ago
This was resolved in 5.2

Original comment by dan.be...@gmail.com on 14 Aug 2010 at 7:28

GoogleCodeExporter commented 8 years ago
Hi Dan, Thanks for the update! Glad it got solved.

Original comment by ianles...@gmail.com on 15 Aug 2010 at 8:06

GoogleCodeExporter commented 8 years ago

Original comment by ianles...@gmail.com on 15 Aug 2010 at 8:07