issues
search
stephane
/
libmodbus
A Modbus library for Linux, Mac OS, FreeBSD and Windows
http://libmodbus.org
GNU Lesser General Public License v2.1
3.44k
stars
1.75k
forks
source link
issues
Newest
Newest
Most commented
Recently updated
Oldest
Least commented
Least recently updated
modbus default port is 502
#771
kay30kim
opened
4 days ago
4
Fix float32 encoding/decoding (#665, #694, #757)
#770
ghorwin
opened
1 week ago
0
How can I use libmodbus server and client in one process
#769
8188
closed
1 week ago
4
Cannot compile ./configure error "Some: command not found"
#768
damago1
closed
3 weeks ago
0
Discuss libmodbus on FreeRTOS / esp-idf
#767
franzhoepfinger
opened
1 month ago
1
Add ESP_PLATFORM support for UART driver selection
#766
franzhoepfinger
opened
1 month ago
1
HAVE_NETINET_IN_H as guard around header
#765
diplfranzhoepfinger
opened
1 month ago
3
An Invalid Pointer Dereference
#764
balckgu1
closed
1 month ago
0
A wild pointer exists in the server
#763
balckgu1
closed
1 month ago
0
Modbus Library Implementation on F28388D ControlCARD
#762
bharatbohara
opened
1 month ago
1
Add termios2 support
#761
philj56
opened
2 months ago
1
modbus-rtu: don't use O_EXCL when opening the device
#760
mhei
opened
2 months ago
0
Buffer overflow after several repeated connections between master and slave using the tcp protocol.
#759
GodLiu1
opened
2 months ago
2
Document macros for error codes corresponding to Modbus exceptions
#758
kyllingstad
opened
2 months ago
1
Clarification on memory layout in _modbus_mapping_t.tab_registers
#757
ghorwin
opened
2 months ago
0
Bad error message "Operation now in progress" for connection timeouts after modbus_set_response_timeout()
#756
psychon
closed
2 months ago
2
Add if (ctx->debug) condition with log
#755
soyoo
closed
2 months ago
2
modbus_receive() function returns -1 on USB serial port (TTL level) devices
#754
ZhiyuanYuanNJ
opened
2 months ago
1
Bugs on libmodbus_src
#753
jongjcho94
closed
2 months ago
1
compile error
#752
ruanyubiao
closed
2 months ago
2
Baud rate higher than 38400 causes Invalid Argument
#751
Kektis
closed
3 months ago
4
unit-test-server crashes with invalid pointer
#750
balckgu1
closed
2 months ago
4
The value of the ctx->backend pointer has been accidentally modified, leading to a Use-After-Free (UAF) vulnerability
#749
balckgu1
closed
2 months ago
3
A deep heap buffer overflow vulnerability exists in modbus_mapping_free
#748
balckgu1
closed
2 months ago
2
Handling Multiple Slave Addresses with libmodbus on a Single Interface
#747
piratkin
opened
4 months ago
0
feat:Add debug log output to caller interface
#746
rongli-eaton
opened
4 months ago
1
ESP-IDF support
#745
fedepell
opened
4 months ago
4
Invalid CRC
#744
theprelior
closed
2 months ago
4
heap-buffer-overflow in in `modbus_write_bits`
#743
MarkLee131
closed
3 weeks ago
1
modbus_rtu_set_serial_mode needs additional flags
#742
jan-kardell
opened
5 months ago
1
Small compatibility improvements for esp32 embedded platforms
#741
fedepell
opened
6 months ago
8
Multiple slaves on the same port.
#740
phu251099
opened
6 months ago
1
Build libmodbus with CMake
#739
jeroendoggen
opened
6 months ago
4
facing crash in libmodbus library
#738
dixitsatyam
opened
8 months ago
1
Set `errno` to `ETIMEDOUT` on TCP connect timeout
#737
kyllingstad
closed
2 months ago
2
With TCP, `modbus_connect()` returns -1 on timeout but does not set `errno`
#736
kyllingstad
closed
2 months ago
0
Broken pipe after Modbus TCP/RTU gateway reboot
#735
marekm72
closed
2 months ago
3
Behaviour of MODBUS_ERROR_RECOVERY_LINK
#734
ssgnh
opened
9 months ago
5
Missing documentation of `errno` values corresponding to Modbus exception codes
#733
kyllingstad
opened
9 months ago
2
Why not merge modbus_flush() directly into functions such as modbus_write(read)_xxx() function?
#732
yanzhang920817
opened
9 months ago
0
Multiple processes running concurrently using libmodbus over Modbus-Rtu
#731
hfelek
opened
9 months ago
5
Setting the coil address to 0 as 1 will immediately be set to 0
#730
yanzhang920817
closed
2 months ago
1
modbus rtu slave on ubuntu 20.04.3
#729
kush930
closed
2 months ago
0
[Project] CLA processing is laggy (want to upstream support for Modbus over USB)
#728
jimklimov
closed
2 months ago
5
incorrect type to store socket on Windows
#727
Swiftkill
opened
9 months ago
0
Possible issue due to different library versions : modbus_receive_confirmation() is not useful
#726
Mr-MoNET
opened
9 months ago
0
modbus_strerror_r() introduced to avoid MT-Unsafe functions (#468)
#725
franzhollerer
opened
9 months ago
0
modbus-tcp协议:ERROR Resource temporarily unavailable
#724
ssgnh
opened
9 months ago
1
CRC Check Error and Slave not the requested One, Ignored
#723
suresh-dersec
opened
10 months ago
0
Connection not bindig
#722
fenilGhoghari
opened
10 months ago
1
Next