svalenti / pessto

pessto pipeline
MIT License
9 stars 6 forks source link

Incorrect unit quoted as `BUNIT` value in spectral frame headers #4

Closed thespacedoctor closed 9 years ago

thespacedoctor commented 9 years ago

The unit quoted is currently erg/cm2/s/A. This needs to change to 10^20 erg/cm2/s/Angstrom

svalenti commented 9 years ago

2d frames should have 10^20 erg/cm2/s/Angstrom while 1d spectra flux calibrated should have erg/cm2/s/Angstrom fixed

thespacedoctor commented 9 years ago

Can you please change erg/cm2/s/A to erg/cm2/s/Angstrom in 1D spectra headers? (At ESO's request!)

svalenti commented 9 years ago

I think I fixed it in the bug branch please check and close

thespacedoctor commented 9 years ago

Yes - this keyword has now been corrected - tested with pipeline v 2.2.6