Open UffeJakobsen opened 6 months ago
Hi Uffe, sorry, I forgot to write. The thing, that I can do is writing "IEC-cable required!" on the board. Since there is not much space and I don't want to change the board size or layout, I have resized the "User Port/Parallel Adaptor" text and re-formated it (made it smaller). The warning is placed above the connector in a prominent size.
I will do the same on the label for the 3D printed case. After finishing it, I will release gerbers with an updated silk screen.
That sounds good. Thanks :-)
Sorry... took a while, but now, the updates are uploaded
Hi,
As a common ground is missing from the parallel cable between C64 and 1541:
I believe that it would make sense to include a written warning that the serial IEC cable should be connected at any time - as it provides a common ground connection between the C64 and the 1541.
Without the IEC cable connected the user - if unlucky - may fry either the CIA and/or VIA due to potential differences due to missing ground