dirk99 commented 1 year ago

Hello, I looked at the Tread #20/32 but I don't understand what I need to adjust for my solution. I would like to control the Soalx inverter with the power meter. I'm using an SDM72 which is not from Solax but which counts 3 phases. Accordingly, the SDM72 also has consultative registers, as is the case with the SDM230 with the 30013 register. For the SDM72 it would be the register 30053 Total System Power. What does the digestion of the Modbus have to look like? AB from the Sloax parallel with Smartmeter and the esphome? The ESP Home only uses one UART. Does the ESPHOME convert any data between smartmeter ans solax inverter?

Many thanks in advance.

Greetings Dirk

syssi commented 1 year ago

I will provide some details tomorrow. What's the distance between the SDM and your Solar?

dirk99 commented 1 year ago

The distance is 40-45m

syssi commented 1 year ago

In this case I would suggest two ESPHome node. One for driving the limiter of the solax using this project and another ESP to retrieve the power consumption from the SDM and publish the measurement via MQTT or native API.

dirk99 commented 1 year ago

The distance is no problem. I suggest one esp node. Between the two components exist cat7 cable.

syssi commented 1 year ago

Alright. A single ESP setup is fine too. ESPHome supports multiple UARTs on a ESP8266 because of a software serial implementation. There is just one hardware UART available. If you assign any other GPIO to the uart component the software serial implementation is used. If you don't trust the software serial implementation please use a ESP32. Here are 3 hardware UARTs accessible.

If you enable the meter mode of the Solax inverter the device will be the modbus master. The solax polls periodically a specific slave address. This ESPHome implementation forms a modbus slave and is able to react to the Solax queries. This setup requires the first UART.

A second UART is required for the RS485 communication between the SDM and the ESPHome node. On this bus the ESPHome node is the modbus master and the SDM response to requests as slave.

The final setup should look like this:

Solax <-- RS485 module --> ESP32 <--> RS485 module <--> SDM

Feel free to ask more questions. If you are new to ESPHome there are a lot of concepts you should know/learn. :-)

dirk99 commented 1 year ago

What is the function of your project esp8266-meter-gateway.yaml?

syssi commented 1 year ago

Decoding the solax meter request and respond. The YAML example subscribes to a MQTT topic to retrieve power consumption from a generic source (smartmeter) and forwards this measurement to the solax if it's requested.

syssi commented 1 year ago

I assume you will remove the MQTT part from this configuration and use the SDM component instead to provide the power consumption sensor entity: https://esphome.io/components/sensor/sdm_meter.html

dirk99 commented 1 year ago

If I wrote the mqtt stat.EZ3.P_Wirk_L1 with the power consumption from smart meter your scrip transmit it to the solax inverter? This should be a easy way for me, because I have all thinks in my iobroker.

syssi commented 1 year ago

Correct! The implementation does pick up a measurement (float) from the instantaneous_power_topic and passes this value to the solax inverter if it's requested (by the solax meter mode).

dirk99 commented 1 year ago

If i connect my Solax inverter to ESPhome ans set continously the MQTT Topic with the consumtion from my smartmeter the log is shown a meter fault YAML:

substitutions:
  name: solax-meter-gateway
  device_description: "Control the export of a Solax X1 mini via RS485"
  external_components_source: github://syssi/esphome-modbus-solax-x1@main
  instantaneous_power_topic: "SolaxPowerControl/P_Wirk_L1"
  tx_pin: GPIO17
  rx_pin: GPIO16

esphome:
  name: ${name}
  comment: ${device_description}
  project:
    name: "syssi.esphome-modbus-solax-x1"
    version: 2.1.0

esp32:
  board: esp32dev
  framework:
    type: arduino

external_components:
  - source: ${external_components_source}
    refresh: 0s

wifi:
  ssid: <SSID>
  password: <Passphrase>

ota:

logger:
  level: DEBUG

api:
  reboot_timeout: 0s

mqtt:
  broker: <IP>
  port: 2884 
  username: <User>
  password: <Pass>
  id: mqtt_client

uart:
  id: uart_0
  baud_rate: 9600
  tx_pin: ${tx_pin}
  rx_pin: ${rx_pin}
  debug:
    direction: BOTH

solax_meter_modbus:
  - id: modbus0
    uart_id: uart_0
#    flow_control_pin: GPIO0

solax_meter_gateway:
  solax_meter_modbus_id: modbus0
  address: 0x01

  # The state of this sensor (instantaneous power in watt) is used as source
  power_id: powermeter0
  power_sensor_inactivity_timeout: 5s
  update_interval: 1s

sensor:
  - id: powermeter0
    internal: true
    platform: mqtt_subscribe
    name: "${name} instantaneous power consumption"
    topic: "${instantaneous_power_topic}"
    accuracy_decimals: 2
    unit_of_measurement: W
    device_class: power

  - platform: solax_meter_gateway
    power_demand:
      name: "${name} power demand"

text_sensor:
  - platform: solax_meter_gateway
    operation_mode:
      name: "${name} operation mode"

switch:
  - platform: solax_meter_gateway
    emergency_power_off:
      name: "${name} emergency power off"
      restore_mode: RESTORE_DEFAULT_OFF

Log:

INFO Waiting for result...
INFO OTA successful
INFO Successfully uploaded program.
INFO Starting log output from solax-meter-gateway.local using esphome API
WARNING Can't connect to ESPHome API for solax-meter-gateway.local: Error resolving IP address: [Errno -2] Name or service not known
INFO Trying to connect to solax-meter-gateway.local in the background
INFO Successfully connected to solax-meter-gateway.local
[10:39:16][I][app:102]: ESPHome version 2023.5.5 compiled on Jun  5 2023, 10:38:46
[10:39:16][I][app:104]: Project syssi.esphome-modbus-solax-x1 version 2.1.0
[10:39:16][C][wifi:505]: WiFi:
[10:39:16][C][wifi:363]:   Local MAC: C4:4F:33:6A:53:01
[10:39:16][C][wifi:364]:   SSID: 'home'[redacted]
[10:39:16][C][wifi:365]:   IP Address: 192.168.168.163
[10:39:16][C][wifi:367]:   BSSID: F0:9F:C2:F1:F1:5C[redacted]
[10:39:16][C][wifi:368]:   Hostname: 'solax-meter-gateway'
[10:39:16][C][wifi:370]:   Signal strength: -74 dB ▂▄▆█
[10:39:16][C][wifi:374]:   Channel: 11
[10:39:16][C][wifi:375]:   Subnet: 255.255.255.0
[10:39:16][C][wifi:376]:   Gateway: 192.168.168.1
[10:39:16][C][wifi:377]:   DNS1: 192.168.168.1
[10:39:16][C][wifi:378]:   DNS2: 8.8.8.8
[10:39:16][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[10:39:16][C][logger:301]: Logger:
[10:39:16][C][logger:302]:   Level: DEBUG
[10:39:16][C][logger:303]:   Log Baud Rate: 115200
[10:39:16][C][logger:305]:   Hardware UART: UART0
[10:39:16][C][uart.arduino_esp32:124]: UART Bus 1:
[10:39:16][C][uart.arduino_esp32:125]:   TX Pin: GPIO17
[10:39:16][C][uart.arduino_esp32:126]:   RX Pin: GPIO16
[10:39:16][C][uart.arduino_esp32:128]:   RX Buffer Size: 256
[10:39:16][C][uart.arduino_esp32:130]:   Baud Rate: 9600 baud
[10:39:16][C][uart.arduino_esp32:131]:   Data Bits: 8
[10:39:16][C][uart.arduino_esp32:132]:   Parity: NONE
[10:39:16][C][uart.arduino_esp32:133]:   Stop bits: 1
[10:39:16][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[10:39:16][D][sensor:094]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[10:39:16][W][solax_meter_gateway:021]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[10:39:16][C][solax_meter_modbus:096]: SolaxMeterModbus:
[10:39:17][C][solax_meter_gateway:091]: SolaxMeterGateway:
[10:39:17][C][solax_meter_gateway:092]:   Address: 0x01
[10:39:17][C][solax_meter_gateway:093]:   Power Demand 'solax-meter-gateway power demand'
[10:39:17][C][solax_meter_gateway:093]:     Device Class: 'power'
[10:39:17][C][solax_meter_gateway:093]:     State Class: ''
[10:39:17][C][solax_meter_gateway:093]:     Unit of Measurement: 'W'
[10:39:17][C][solax_meter_gateway:093]:     Accuracy Decimals: 0
[10:39:17][C][solax_meter_gateway:094]:   Operation name 'solax-meter-gateway operation mode'
[10:39:17][C][solax_meter_gateway:094]:     Icon: 'mdi:heart-pulse'
[10:39:17][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[10:39:17][C][solax_meter_gateway.switch:068]: SolaxMeterGateway Switch 'solax-meter-gateway emergency power off'
[10:39:17][C][solax_meter_gateway.switch:070]:   Icon: 'mdi:power'
[10:39:17][C][solax_meter_gateway.switch:091]:   Restore Mode: restore defaults to OFF
[10:39:17][C][solax_meter_gateway.switch:052]:   Restore Mode: Restore (Defaults to OFF)
[10:39:17][C][mdns:108]: mDNS:
[10:39:17][C][mdns:109]:   Hostname: solax-meter-gateway
[10:39:17][C][ota:093]: Over-The-Air Updates:
[10:39:17][C][ota:094]:   Address: solax-meter-gateway.local:3232
[10:39:17][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[10:39:17][D][sensor:094]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[10:39:17][W][solax_meter_gateway:021]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[10:39:17][C][api:138]: API Server:
[10:39:17][C][api:139]:   Address: solax-meter-gateway.local:6053
[10:39:17][C][api:143]:   Using noise encryption: NO
[10:39:17][C][mqtt:065]: MQTT:
[10:39:17][C][mqtt:067]:   Server Address: 192.168.168.201:2884 (192.168.168.201)
[10:39:17][C][mqtt:068]:   Username: 'sonoff'[redacted]
[10:39:17][C][mqtt:069]:   Client ID: 'solax-meter-gateway-c44f336a5301'[redacted]
[10:39:17][C][mqtt:071]:   Discovery prefix: 'homeassistant'
[10:39:17][C][mqtt:072]:   Discovery retain: YES
[10:39:17][C][mqtt:074]:   Topic Prefix: 'solax-meter-gateway'
[10:39:17][C][mqtt:076]:   Log Topic: 'solax-meter-gateway/debug'
[10:39:17][C][mqtt:079]:   Availability: 'solax-meter-gateway/status'
[10:39:17][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[10:39:17][C][mqtt_subscribe.sensor:031]: MQTT Subscribe 'solax-meter-gateway instantaneous power consumption'
[10:39:17][C][mqtt_subscribe.sensor:031]:   Device Class: 'power'
[10:39:17][C][mqtt_subscribe.sensor:031]:   State Class: ''
[10:39:17][C][mqtt_subscribe.sensor:031]:   Unit of Measurement: 'W'
[10:39:17][C][mqtt_subscribe.sensor:031]:   Accuracy Decimals: 2
[10:39:17][C][mqtt_subscribe.sensor:032]:   Topic: SolaxPowerControl/P_Wirk_L1
[10:39:17][C][mqtt.sensor:027]: MQTT Sensor 'solax-meter-gateway power demand':
[10:39:17][C][mqtt.sensor:031]:   State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state'
[10:39:17][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[10:39:17][D][sensor:094]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[10:39:17][W][solax_meter_gateway:021]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[10:39:17][C][mqtt.text_sensor:023]: MQTT Text Sensor 'solax-meter-gateway operation mode':
[10:39:17][C][mqtt.text_sensor:024]:   State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state'
[10:39:17][C][mqtt.switch:041]: MQTT Switch 'solax-meter-gateway emergency power off': 
[10:39:17][C][mqtt.switch:042]:   State Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/state'
[10:39:17][C][mqtt.switch:042]:   Command Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/command'
[10:39:17][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[10:39:17][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[10:39:17][D][sensor:094]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[10:39:17][W][solax_meter_gateway:021]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[10:39:17][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[10:39:17][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[10:39:17][D][sensor:094]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[10:39:18][W][solax_meter_gateway:021]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[10:39:18][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
syssi commented 1 year ago

Could you monitor the traffic on topic SolaxPowerControl/P_Wirk_L1? It looks like the node doesn't receive any power conumption measurements. If you have access to a linux host please provide the output of:

mosquitto_sub -t 'SolaxPowerControl/P_Wirk_L1' -v
dirk99 commented 1 year ago

Witch traffic do you want to see? Iobroker has not this functions. Ist a wireshark helpful?

syssi commented 1 year ago

You could pick any MQTT client software to have a look at your MQTT traffic. It looks like there is no traffic on topic SolaxPowerControl/P_Wirk_L1 at the moment.

dirk99 commented 1 year ago

i can see traffic on the MQTT Topic. I have changed the Hardware to esp8266 because it looks like, that there is no TX traffic on the modbus converter. I use the modbus shield without flow controll. Attached the log.

INFO ESPHome 2023.5.5 INFO Reading configuration /opt/iobroker/iobroker-data/esphome.0/solaxgatewaytosmartmeter.yaml... INFO Updating https://github.com/syssi/esphome-modbus-solax-x1.git@main INFO Starting log output from solax-meter-gateway.local using esphome API INFO Successfully connected to solax-meter-gateway.local [10:11:29][I][app:102]: ESPHome version 2023.5.5 compiled on Jun 5 2023, 17:44:47 [10:11:29][I][app:104]: Project syssi.esphome-modbus-solax-x1 version 2.1.0

[10:11:29][C][wifi:363]: Local MAC: E8:9F:6D:87:4D:DE [10:11:29][C][wifi:364]: SSID: 'home'[redacted] [10:11:29][C][wifi:365]: IP Address: 192.168.168.165 [10:11:29][C][wifi:366]: BSSID: F0:9F:C2:F1:F1:5C[redacted]

[10:11:29][C][wifi:370]: Signal strength: -72 dB ▂▄▆█ [10:11:29][C][wifi:374]: Channel: 6 [10:11:29][C][wifi:375]: Subnet: 255.255.255.0 [10:11:29][C][wifi:376]: Gateway: 192.168.168.1 [10:11:29][C][wifi:377]: DNS1: 192.168.168.1 [10:11:29][C][wifi:378]: DNS2: 8.8.8.8 [10:11:29][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:29][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:29][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons

[10:11:29][C][logger:302]: Level: DEBUG [10:11:29][C][logger:303]: Log Baud Rate: 115200 [10:11:29][C][logger:305]: Hardware UART: UART0 [10:11:29][C][uart.arduino_esp8266:102]: UART Bus: [10:11:29][C][uart.arduino_esp8266:103]: TX Pin: GPIO4 [10:11:29][C][uart.arduino_esp8266:104]: RX Pin: GPIO5 [10:11:29][C][uart.arduino_esp8266:106]: RX Buffer Size: 256 [10:11:29][C][uart.arduino_esp8266:108]: Baud Rate: 9600 baud [10:11:29][C][uart.arduino_esp8266:109]: Data Bits: 8 [10:11:29][C][uart.arduino_esp8266:110]: Parity: NONE [10:11:29][C][uart.arduino_esp8266:111]: Stop bits: 1 [10:11:29][C][uart.arduino_esp8266:115]: Using software serial [10:11:29][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8:01:03:00:0B:00:01:F5:C8

[10:11:29][C][solax_meter_gateway:092]: Address: 0x01 [10:11:29][C][solax_meter_gateway:093]: Power Demand 'solax-meter-gateway power demand' [10:11:29][C][solax_meter_gateway:093]: Device Class: 'power' [10:11:29][C][solax_meter_gateway:093]: State Class: '' [10:11:29][C][solax_meter_gateway:093]: Unit of Measurement: 'W' [10:11:29][C][solax_meter_gateway:093]: Accuracy Decimals: 0 [10:11:29][C][solax_meter_gateway:094]: Operation name 'solax-meter-gateway operation mode'

[10:11:29][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:29][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:29][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:29][C][solax_meter_gateway.switch:068]: SolaxMeterGateway Switch 'solax-meter-gateway emergency power off'

[10:11:29][C][solax_meter_gateway.switch:090]: Restore Mode: restore defaults to OFF [10:11:29][C][solax_meter_gateway.switch:052]: Restore Mode: Restore (Defaults to OFF)

[10:11:29][C][mdns:109]: Hostname: solax-meter-gateway [10:11:29][C][ota:093]: Over-The-Air Updates: [10:11:29][C][ota:094]: Address: solax-meter-gateway.local:8266 [10:11:29][C][ota:097]: Using Password. [10:11:29][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:29][C][api:138]: API Server: [10:11:29][C][api:139]: Address: solax-meter-gateway.local:6053 [10:11:29][C][api:141]: Using noise encryption: YES

[10:11:29][C][mqtt:066]: Server Address: 192.168.168.201:2884 (192.168.168.201) [10:11:29][C][mqtt:068]: Username: 'sonoff'[redacted] [10:11:29][C][mqtt:069]: Client ID: 'solax-meter-gateway-e89f6d874dde'[redacted] [10:11:29][C][mqtt:071]: Discovery prefix: 'homeassistant' [10:11:29][C][mqtt:072]: Discovery retain: YES [10:11:29][C][mqtt:074]: Topic Prefix: 'solax-meter-gateway' [10:11:29][C][mqtt:076]: Log Topic: 'solax-meter-gateway/debug'

[10:11:30][C][mqtt_subscribe.sensor:031]: MQTT Subscribe 'solax-meter-gateway instantaneous power consumption' [10:11:30][C][mqtt_subscribe.sensor:031]: Device Class: 'power' [10:11:30][C][mqtt_subscribe.sensor:031]: State Class: '' [10:11:30][C][mqtt_subscribe.sensor:031]: Unit of Measurement: 'W' [10:11:30][C][mqtt_subscribe.sensor:031]: Accuracy Decimals: 2 [10:11:30][C][mqtt_subscribe.sensor:032]: Topic: SolaxPowerControl/P_Wirk_L1 [10:11:30][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:30][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:30][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:30][C][mqtt.sensor:027]: MQTT Sensor 'solax-meter-gateway power demand': [10:11:30][C][mqtt.sensor:031]: State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' [10:11:30][C][mqtt.text_sensor:023]: MQTT Text Sensor 'solax-meter-gateway operation mode': [10:11:30][C][mqtt.text_sensor:024]: State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' [10:11:30][C][mqtt.switch:041]: MQTT Switch 'solax-meter-gateway emergency power off': [10:11:30][C][mqtt.switch:042]: State Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/state' [10:11:30][C][mqtt.switch:042]: Command Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/command' [10:11:30][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:30][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:30][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:30][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:30][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:30][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:30][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:30][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:30][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:30][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:30][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:30][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:30][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:31][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:31][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:31][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:31][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:31][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:31][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:31][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:31][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:31][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:31][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:31][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:31][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:31][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:31][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:31][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:31][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:32][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:32][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:32][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:32][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:32][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:32][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:32][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:32][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:32][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:32][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:32][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:32][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:32][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:32][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:32][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:33][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:33][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:33][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:33][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:33][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [10:11:33][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [10:11:33][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [10:11:33][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [10:11:33][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8

syssi commented 1 year ago

Ich versuche es mal in Deutsch in der Hoffnung, dass wir uns so flinker verstaendigen koennen: Solange der Komponente solax_meter_gateway kein gültiger Wert vom Smartmeter zur Verfügung steht, hat sie keine Information, welche sie an den Solax weitergeben koennte. Das ist meine aktuelle Erklaerung, weshalb gerade nichts an den Solax gesendet wird.

Stattdessen scheint das Problem weiterhin beim Einsammeln des aktuellen Verbrauchswert zu liegen. Ich habe den Eindruck, dass keine Verbindung zu deinem MQTT-Broker aufgenommen werden kann und deshalb auch keine Messwerte vom Topic SolaxPowerControl/P_Wirk_L1 vorliegen. Ist der Port 2884 für unverschlüsselten Verkehr erreichbar? Ggf. hilft noch ein Wireshark-Mitschnitt um zu verstehen, wie die Kommunikation zwischen ESPHome Node und MQTT Port 2884 aktuell aussieht. Ggf. steht auch im IoBroker-Log etwas, wie mit dem Client umgegangen wird.

dirk99 commented 1 year ago

Der Port 2884 ist unsecured mit User und Passwort zu erreichen. Ich sehe auch mit einem mqtt Client mit den gleichen Einstellungen wie das topic im Rytmus von ca. 2sek geändert wird und auch einen positive bzw. Negativen Wert bekommt mit Nachkommastellen (Float). Ich werde heute Abend mal ein Wireshark Protokoll ziehen. Meine Vermutung liegt eher an der Hardware. Parallel werde ich es mal auf Flow control umbauen. Teile habe ich dafür da.

syssi commented 1 year ago
[10:11:33][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8

zeigt an, dass eine Nachricht vom Solax herein kommt. Es handelt sich um das Handshake-Frame, welches von der Komponente unmittelbar mit einer ausgehenden Nachricht (>>>) beantwortet werden sollte:

https://github.com/syssi/esphome-solax-x1-mini/blob/main/components/solax_meter_gateway/solax_meter_gateway.cpp#L33-L37

Ich habe das Gefuehl, dass in deiner Konfiguration noch etwas nicht stimmt. Egal ob die Hardware funktioniert wie sie soll, haette man die ausgehende Nachricht (01:03:02:00:00) im Log sehen muessen. Ich gehe davon aus, dass deine Hardware sauber funktioniert, da du Nachrichten vom Solax empfangen kannst.

Kannst du mir deine YAML-Konfiguration zur Verfügung stellen? Dann kann ich deinen Aufbau nachstellen.

dirk99 commented 1 year ago

anbei meine Config und ein Log. im Log sieht um 15:03 für mich so aus, als wenn das ein paar Daten geschickt werden, aber nach ein paar Meldungen ist Schluß. Kann es daran liegen, dass paralell noch ein Tasmota auf dem Bus die Abfragen am Solax macht? Ist es eigentlich möglich, dass die Smartmeter Konvertierung und parallel die Datenabfrage vom ESPhome per MQTT übermittelt wird, dann könnte ich den Tasmota vom Bus entfernen. Config YAML

substitutions:
  name: solax-meter-gateway
  device_description: "Control the export of a Solax X1 mini via RS485"
  external_components_source: github://syssi/esphome-modbus-solax-x1@main
  instantaneous_power_topic: "SolaxPowerControl/P_Wirk_L1"
  tx_pin: GPIO4
  rx_pin: GPIO5

esphome:
  name: ${name}
  comment: ${device_description}
  project:
    name: "syssi.esphome-modbus-solax-x1"
    version: 2.1.0

esp8266:
  board: d1_mini

external_components:
  - source: ${external_components_source}
    refresh: 0s

wifi:
  ssid: home
  password: <SSID Kennwort>

ota:
  password: "<PW>"

logger:
  level: DEBUG

api:
  encryption:
    key: "<key>"

mqtt:
  broker: 192.168.168.201
  port: 2884 
  username: <mqtt_user>
  password: <mqtt_PW>
  id: mqtt_client

uart:
  id: uart_0
  baud_rate: 9600
  tx_pin: ${tx_pin}
  rx_pin: ${rx_pin}
  debug:
    direction: BOTH

solax_meter_modbus:
  - id: modbus0
    uart_id: uart_0
#    flow_control_pin: GPIO0

solax_meter_gateway:
  solax_meter_modbus_id: modbus0
  address: 0x01

  # The state of this sensor (instantaneous power in watt) is used as source
  power_id: powermeter0
  power_sensor_inactivity_timeout: 5s
  update_interval: 1s

sensor:
  - id: powermeter0
    internal: true
    platform: mqtt_subscribe
    name: "${name} instantaneous power consumption"
    topic: "${instantaneous_power_topic}"
    accuracy_decimals: 2
    unit_of_measurement: W
    device_class: power

  - platform: solax_meter_gateway
    power_demand:
      name: "${name} power demand"

text_sensor:
  - platform: solax_meter_gateway
    operation_mode:
      name: "${name} operation mode"

switch:
  - platform: solax_meter_gateway
    emergency_power_off:
      name: "${name} emergency power off"
      restore_mode: RESTORE_DEFAULT_OFF
**************************************************************************************************************************************
Log
INFO ESPHome 2023.5.5
INFO Reading configuration /opt/iobroker/iobroker-data/esphome.0/solaxgatewaytosmartmeter.yaml...
INFO Updating https://github.com/syssi/esphome-modbus-solax-x1.git@main
INFO Generating C++ source...
INFO Compiling app...
Processing solax-meter-gateway (board: d1_mini; framework: arduino; platform: platformio/espressif8266@3.2.0)
--------------------------------------------------------------------------------
HARDWARE: ESP8266 80MHz, 80KB RAM, 4MB Flash
Dependency Graph
|-- ESP8266WiFi @ 1.0
|-- ESP8266mDNS @ 1.2
|-- noise-c @ 0.1.4
|   |-- libsodium @ 1.10018.1
|-- AsyncMqttClient-esphome @ 0.8.6
|   |-- ESPAsyncTCP-esphome @ 1.2.3
|-- ArduinoJson @ 6.18.5
Compiling .pioenvs/solax-meter-gateway/src/main.cpp.o
Linking .pioenvs/solax-meter-gateway/firmware.elf
RAM:   [====      ]  41.3% (used 33820 bytes from 81920 bytes)
Flash: [=====     ]  47.7% (used 498281 bytes from 1044464 bytes)
Building .pioenvs/solax-meter-gateway/firmware.bin
esp8266_copy_factory_bin([".pioenvs/solax-meter-gateway/firmware.bin"], [".pioenvs/solax-meter-gateway/firmware.elf"])
========================= [SUCCESS] Took 8.83 seconds =========================
INFO Successfully compiled program.
INFO Resolving IP address of solax-meter-gateway.local
INFO  -> 192.168.168.165
INFO Uploading /opt/iobroker/iobroker-data/esphome.0/.esphome/build/solax-meter-gateway/.pioenvs/solax-meter-gateway/firmware.bin (502432 bytes)
INFO Compressed to 347710 bytes
Uploading: [============================================================] 100% Done...

INFO Waiting for result...
INFO OTA successful
INFO Successfully uploaded program.
INFO Starting log output from solax-meter-gateway.local using esphome API
WARNING Can't connect to ESPHome API for solax-meter-gateway.local: Error resolving IP address: [Errno -2] Name or service not known
INFO Trying to connect to solax-meter-gateway.local in the background
INFO Successfully connected to solax-meter-gateway.local
[15:02:59][I][app:102]: ESPHome version 2023.5.5 compiled on Jun  6 2023, 15:02:26
[15:02:59][I][app:104]: Project syssi.esphome-modbus-solax-x1 version 2.1.0
[15:02:59][C][wifi:505]: WiFi:
[15:02:59][C][wifi:363]:   Local MAC: E8:9F:6D:87:4D:DE
[15:02:59][C][wifi:364]:   SSID: 'home'[redacted]
[15:02:59][C][wifi:365]:   IP Address: 192.168.168.165
[15:02:59][C][wifi:366]:   BSSID: F0:9F:C2:F1:F1:5C[redacted]
[15:02:59][C][wifi:368]:   Hostname: 'solax-meter-gateway'
[15:02:59][C][wifi:370]:   Signal strength: -67 dB ▂▄▆█
[15:02:59][C][wifi:374]:   Channel: 6
[15:02:59][C][wifi:375]:   Subnet: 255.255.255.0
[15:02:59][C][wifi:376]:   Gateway: 192.168.168.1
[15:02:59][C][wifi:377]:   DNS1: 192.168.168.1
[15:02:59][C][wifi:378]:   DNS2: 8.8.8.8
[15:02:59][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:02:59][C][logger:301]: Logger:
[15:02:59][C][logger:302]:   Level: DEBUG
[15:02:59][C][logger:303]:   Log Baud Rate: 115200
[15:02:59][C][logger:305]:   Hardware UART: UART0
[15:02:59][C][uart.arduino_esp8266:102]: UART Bus:
[15:03:00][C][uart.arduino_esp8266:103]:   TX Pin: GPIO4
[15:03:00][C][uart.arduino_esp8266:104]:   RX Pin: GPIO5
[15:03:00][C][uart.arduino_esp8266:106]:   RX Buffer Size: 256
[15:03:00][C][uart.arduino_esp8266:108]:   Baud Rate: 9600 baud
[15:03:00][C][uart.arduino_esp8266:109]:   Data Bits: 8
[15:03:00][C][uart.arduino_esp8266:110]:   Parity: NONE
[15:03:00][C][uart.arduino_esp8266:111]:   Stop bits: 1
[15:03:00][C][uart.arduino_esp8266:115]:   Using software serial
[15:03:00][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:00][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:00][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:00][C][solax_meter_modbus:096]: SolaxMeterModbus:
[15:03:00][C][solax_meter_gateway:091]: SolaxMeterGateway:
[15:03:00][C][solax_meter_gateway:092]:   Address: 0x01
[15:03:00][C][solax_meter_gateway:093]:   Power Demand 'solax-meter-gateway power demand'
[15:03:00][C][solax_meter_gateway:093]:     Device Class: 'power'
[15:03:00][C][solax_meter_gateway:093]:     State Class: ''
[15:03:00][C][solax_meter_gateway:093]:     Unit of Measurement: 'W'
[15:03:00][C][solax_meter_gateway:093]:     Accuracy Decimals: 0
[15:03:00][C][solax_meter_gateway:094]:   Operation name 'solax-meter-gateway operation mode'
[15:03:00][C][solax_meter_gateway:094]:     Icon: 'mdi:heart-pulse'
[15:03:00][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:00][C][solax_meter_gateway.switch:068]: SolaxMeterGateway Switch 'solax-meter-gateway emergency power off'
[15:03:00][C][solax_meter_gateway.switch:070]:   Icon: 'mdi:power'
[15:03:00][C][solax_meter_gateway.switch:090]:   Restore Mode: restore defaults to OFF
[15:03:00][C][solax_meter_gateway.switch:052]:   Restore Mode: Restore (Defaults to OFF)
[15:03:00][C][mdns:108]: mDNS:
[15:03:00][C][mdns:109]:   Hostname: solax-meter-gateway
[15:03:00][C][ota:093]: Over-The-Air Updates:
[15:03:00][C][ota:094]:   Address: solax-meter-gateway.local:8266
[15:03:00][C][ota:097]:   Using Password.
[15:03:00][C][api:138]: API Server:
[15:03:00][C][api:139]:   Address: solax-meter-gateway.local:6053
[15:03:00][C][api:141]:   Using noise encryption: YES
[15:03:00][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:00][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:00][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:00][C][mqtt:065]: MQTT:
[15:03:00][C][mqtt:066]:   Server Address: 192.168.168.201:2884 (192.168.168.201)
[15:03:00][C][mqtt:068]:   Username: 'sonoff'[redacted]
[15:03:00][C][mqtt:069]:   Client ID: 'solax-meter-gateway-e89f6d874dde'[redacted]
[15:03:00][C][mqtt:071]:   Discovery prefix: 'homeassistant'
[15:03:00][C][mqtt:072]:   Discovery retain: YES
[15:03:00][C][mqtt:074]:   Topic Prefix: 'solax-meter-gateway'
[15:03:00][C][mqtt:076]:   Log Topic: 'solax-meter-gateway/debug'
[15:03:00][C][mqtt:079]:   Availability: 'solax-meter-gateway/status'
[15:03:00][C][mqtt_subscribe.sensor:031]: MQTT Subscribe 'solax-meter-gateway instantaneous power consumption'
[15:03:00][C][mqtt_subscribe.sensor:031]:   Device Class: 'power'
[15:03:00][C][mqtt_subscribe.sensor:031]:   State Class: ''
[15:03:00][C][mqtt_subscribe.sensor:031]:   Unit of Measurement: 'W'
[15:03:00][C][mqtt_subscribe.sensor:031]:   Accuracy Decimals: 2
[15:03:00][C][mqtt_subscribe.sensor:032]:   Topic: SolaxPowerControl/P_Wirk_L1
[15:03:00][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:00][C][mqtt.sensor:027]: MQTT Sensor 'solax-meter-gateway power demand':
[15:03:00][C][mqtt.sensor:031]:   State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state'
[15:03:00][C][mqtt.text_sensor:023]: MQTT Text Sensor 'solax-meter-gateway operation mode':
[15:03:00][C][mqtt.text_sensor:024]:   State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state'
[15:03:00][C][mqtt.switch:041]: MQTT Switch 'solax-meter-gateway emergency power off': 
[15:03:00][C][mqtt.switch:042]:   State Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/state'
[15:03:00][C][mqtt.switch:042]:   Command Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/command'
[15:03:00][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:00][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:00][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:00][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:00][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:00][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:00][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:00][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:01][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:01][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:01][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:01][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:01][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:01][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:01][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:01][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:01][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:01][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:01][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:01][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:01][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:01][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:01][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:02][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:02][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:02][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:02][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:02][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:02][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:02][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:02][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:02][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:02][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:02][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:02][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:02][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:02][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:03][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:03][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:03][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:03][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:03][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:03][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:03][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:03][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:03][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:03][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:03][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:03][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:03][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:03][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:03][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:04][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:04][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:04][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:04][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:04][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:04][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:04][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:04][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:04][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:04][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:04][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:04][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:04][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:04][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:04][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:04][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:05][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:05][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:05][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:05][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:05][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:05][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:05][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:05][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:05][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:05][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:05][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:05][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:05][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:05][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:05][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:06][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[15:03:06][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:06][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:06][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:06][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[15:03:06][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:06][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:06][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:06][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[15:03:06][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:06][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:06][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
[15:03:06][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[15:03:07][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault'
[15:03:07][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy
[15:03:07][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons
syssi commented 1 year ago

Der Teil sieht gut aus:

[15:03:00][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:00][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:00][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:00][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:00][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:00][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:00][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:00][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:01][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:01][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:01][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:01][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:01][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:01][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:01][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:01][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:01][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:01][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:01][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:01][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F
[15:03:01][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[15:03:01][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 474.06000 W with 0 decimals of accuracy
[15:03:01][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[15:03:02][D][uart_debug:114]: >>> 01:03:02:01:DA:38:4F

In diesem Zeitraum kannte die Steuerung einen aktuellen Verbrauch (474W) vom Stromzaehler und hat den Inverter aufgefordert diese Leistung zu produzieren.

Ab hier wurde etwas seltsames empfangen:

[15:03:02][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy

nan bedeutet in diesem Kontext "not a number". In anderen Worten: Der Wert konnte nicht sauber in eine Fließkommazahl konvertiert werden. Wir sollten das Log-Level der MQTT-Komponente anheben, so dass wir die rohen Daten auf dem MQTT-Topic im Log sehen können. Ich vermute, dass die Implementierung alle Viere von sich streckt, sobald der Wert negativ wird.

dirk99 commented 1 year ago

Ich habe den Log Level hochgesetzt für MQTT und mittleweile auch die aktuellste Firmware im Umrichter, die heute bekommen habe. Anbei das Log.

INFO ESPHome 2023.5.5 INFO Reading configuration /opt/iobroker/iobroker-data/esphome.0/solaxgatewaytosmartmeter.yaml... INFO Updating https://github.com/syssi/esphome-modbus-solax-x1.git@main INFO Starting log output from solax-meter-gateway.local using esphome API WARNING Can't connect to ESPHome API for solax-meter-gateway.local: Error resolving IP address: [Errno -2] Name or service not known INFO Trying to connect to solax-meter-gateway.local in the background INFO Successfully connected to solax-meter-gateway.local [17:59:08][I][app:102]: ESPHome version 2023.5.5 compiled on Jun 6 2023, 17:54:47 [17:59:08][I][app:104]: Project syssi.esphome-modbus-solax-x1 version 2.1.0

[17:59:08][C][wifi:363]: Local MAC: E8:9F:6D:87:4D:DE [17:59:08][C][wifi:364]: SSID: 'home'[redacted] [17:59:08][C][wifi:365]: IP Address: 192.168.168.165 [17:59:08][C][wifi:366]: BSSID: F0:9F:C2:F1:F1:5C[redacted]

[17:59:08][C][wifi:370]: Signal strength: -76 dB ▂▄▆█ [17:59:08][V][wifi:372]: Priority: 0.0 [17:59:08][C][wifi:374]: Channel: 6 [17:59:08][C][wifi:375]: Subnet: 255.255.255.0 [17:59:08][C][wifi:376]: Gateway: 192.168.168.1 [17:59:08][C][wifi:377]: DNS1: 192.168.168.1 [17:59:08][C][wifi:378]: DNS2: 8.8.8.8 [17:59:08][D][uart_debug:114]: >>> 01:03:02:01:6A:39:FB

[17:59:08][C][logger:302]: Level: VERY_VERBOSE [17:59:08][C][logger:303]: Log Baud Rate: 115200 [17:59:08][C][logger:305]: Hardware UART: UART0 [17:59:08][C][uart.arduino_esp8266:102]: UART Bus: [17:59:08][C][uart.arduino_esp8266:103]: TX Pin: GPIO4 [17:59:08][C][uart.arduino_esp8266:104]: RX Pin: GPIO5 [17:59:08][C][uart.arduino_esp8266:106]: RX Buffer Size: 256 [17:59:08][C][uart.arduino_esp8266:108]: Baud Rate: 9600 baud [17:59:08][C][uart.arduino_esp8266:109]: Data Bits: 8 [17:59:08][C][uart.arduino_esp8266:110]: Parity: NONE [17:59:08][C][uart.arduino_esp8266:111]: Stop bits: 1 [17:59:08][C][uart.arduino_esp8266:115]: Using software serial [17:59:08][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:08][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9

[17:59:08][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.6A.39.FB (7) [17:59:08][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 362.420013 [17:59:09][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 362.42001 W with 0 decimals of accuracy [17:59:09][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='362' retain=1) [17:59:09][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On [17:59:09][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On' [17:59:09][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1) [17:59:09][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s). [17:59:09][V][component:205]: Components should block for at most 20-30ms.

[17:59:09][D][uart_debug:114]: >>> 01:03:02:01:6A:39:FB

[17:59:09][C][solax_meter_gateway:092]: Address: 0x01 [17:59:09][C][solax_meter_gateway:093]: Power Demand 'solax-meter-gateway power demand' [17:59:09][C][solax_meter_gateway:093]: Device Class: 'power' [17:59:09][C][solax_meter_gateway:093]: State Class: '' [17:59:09][C][solax_meter_gateway:093]: Unit of Measurement: 'W' [17:59:09][C][solax_meter_gateway:093]: Accuracy Decimals: 0 [17:59:09][C][solax_meter_gateway:094]: Operation name 'solax-meter-gateway operation mode'

[17:59:09][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:09][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9

[17:59:09][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.6A.39.FB (7) [17:59:09][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 362.420013 [17:59:09][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 362.42001 W with 0 decimals of accuracy [17:59:09][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='362' retain=1) [17:59:09][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On [17:59:09][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On' [17:59:09][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1) [17:59:09][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s). [17:59:09][V][component:205]: Components should block for at most 20-30ms. [17:59:09][C][solax_meter_gateway.switch:068]: SolaxMeterGateway Switch 'solax-meter-gateway emergency power off'

[17:59:09][C][solax_meter_gateway.switch:090]: Restore Mode: restore defaults to OFF [17:59:09][C][solax_meter_gateway.switch:052]: Restore Mode: Restore (Defaults to OFF) [17:59:09][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=15718 (now=16794) [17:59:09][D][uart_debug:114]: >>> 01:03:02:01:6A:39:FB

[17:59:09][C][mdns:109]: Hostname: solax-meter-gateway

[17:59:09][V][mdns:112]: - _esphomelib, _tcp, 6053 [17:59:09][V][mdns:114]: TXT: version = 2023.5.5 [17:59:09][V][mdns:114]: TXT: mac = e89f6d874dde [17:59:09][V][mdns:114]: TXT: platform = ESP8266 [17:59:09][V][mdns:114]: TXT: board = d1_mini [17:59:09][V][mdns:114]: TXT: network = wifi [17:59:09][V][mdns:114]: TXT: project_name = syssi.esphome-modbus-solax-x1 [17:59:09][V][mdns:114]: TXT: project_version = 2.1.0 [17:59:09][C][ota:093]: Over-The-Air Updates: [17:59:09][C][ota:094]: Address: solax-meter-gateway.local:8266 [17:59:09][C][ota:097]: Using Password. [17:59:09][W][ota:102]: Last Boot was an unhandled reset, will proceed to safe mode in 7 restarts [17:59:09][VV][scheduler:032]: set_timeout(name='', timeout=0) [17:59:09][C][api:138]: API Server: [17:59:09][C][api:139]: Address: solax-meter-gateway.local:6053 [17:59:09][C][api:141]: Using noise encryption: YES [17:59:09][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=16925 (now=16937) [17:59:09][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:09][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9

[17:59:09][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.6A.39.FB (7) [17:59:09][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 362.420013 [17:59:09][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 362.42001 W with 0 decimals of accuracy [17:59:09][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='362' retain=1) [17:59:09][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On [17:59:09][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On' [17:59:09][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1) [17:59:09][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s). [17:59:09][V][component:205]: Components should block for at most 20-30ms.

[17:59:09][C][mqtt:066]: Server Address: 192.168.168.201:2884 (192.168.168.201) [17:59:09][C][mqtt:068]: Username: 'sonoff'[redacted] [17:59:09][C][mqtt:069]: Client ID: 'solax-meter-gateway-e89f6d874dde'[redacted] [17:59:09][C][mqtt:071]: Discovery prefix: 'homeassistant' [17:59:09][C][mqtt:072]: Discovery retain: YES [17:59:09][C][mqtt:074]: Topic Prefix: 'solax-meter-gateway' [17:59:09][C][mqtt:076]: Log Topic: 'VERY_VERBOSE'

[17:59:09][D][uart_debug:114]: >>> 01:03:02:01:6A:39:FB [17:59:09][C][mqtt_subscribe.sensor:031]: MQTT Subscribe 'solax-meter-gateway instantaneous power consumption' [17:59:09][C][mqtt_subscribe.sensor:031]: Device Class: 'power' [17:59:09][C][mqtt_subscribe.sensor:031]: State Class: '' [17:59:09][C][mqtt_subscribe.sensor:031]: Unit of Measurement: 'W' [17:59:09][C][mqtt_subscribe.sensor:031]: Accuracy Decimals: 2 [17:59:09][C][mqtt_subscribe.sensor:032]: Topic: SolaxPowerControl/P_Wirk_L1 [17:59:09][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:09][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9

[17:59:09][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.6A.39.FB (7) [17:59:09][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 362.420013 [17:59:09][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 362.42001 W with 0 decimals of accuracy [17:59:09][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='362' retain=1) [17:59:09][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On [17:59:09][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On' [17:59:09][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1) [17:59:09][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s). [17:59:09][V][component:205]: Components should block for at most 20-30ms. [17:59:09][C][mqtt.sensor:027]: MQTT Sensor 'solax-meter-gateway power demand': [17:59:09][C][mqtt.sensor:031]: State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' [17:59:09][D][uart_debug:114]: >>> 01:03:02:01:6A:39:FB [17:59:09][C][mqtt.text_sensor:023]: MQTT Text Sensor 'solax-meter-gateway operation mode': [17:59:09][C][mqtt.text_sensor:024]: State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' [17:59:09][C][mqtt.switch:041]: MQTT Switch 'solax-meter-gateway emergency power off': [17:59:09][C][mqtt.switch:042]: State Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/state' [17:59:09][C][mqtt.switch:042]: Command Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/command' [17:59:09][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:09][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9

[17:59:10][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.6A.39.FB (7) [17:59:10][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 362.420013 [17:59:10][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 362.42001 W with 0 decimals of accuracy [17:59:10][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='362' retain=1) [17:59:10][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On [17:59:10][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On' [17:59:10][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1) [17:59:10][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s). [17:59:10][V][component:205]: Components should block for at most 20-30ms. [17:59:10][D][uart_debug:114]: >>> 01:03:02:01:6A:39:FB [17:59:10][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=16718 (now=17724) [17:59:10][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:10][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:10][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:10][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:10][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:10][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:10][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:10][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:10][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.08 s). [17:59:10][V][component:205]: Components should block for at most 20-30ms. [17:59:10][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9 [17:59:10][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:10][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:10][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:10][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:10][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:10][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:10][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:10][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:10][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:10][V][component:205]: Components should block for at most 20-30ms. [17:59:10][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9 [17:59:10][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:10][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:10][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:10][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:10][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:10][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:10][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:10][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:10][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:10][V][component:205]: Components should block for at most 20-30ms. [17:59:10][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9 [17:59:11][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:11][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:11][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:11][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:11][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:11][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:11][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:11][V][component:205]: Components should block for at most 20-30ms. [17:59:11][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9 [17:59:11][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=17718 (now=18718) [17:59:11][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:11][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:11][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:11][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:11][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:11][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:11][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:11][V][component:205]: Components should block for at most 20-30ms. [17:59:11][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9 [17:59:11][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:11][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:11][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:11][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:11][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:11][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:11][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:11][V][component:205]: Components should block for at most 20-30ms. [17:59:11][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9 [17:59:11][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:11][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:11][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:11][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:11][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:11][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:11][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:11][V][component:205]: Components should block for at most 20-30ms. [17:59:11][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9 [17:59:12][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:12][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:12][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:12][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:12][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:12][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:12][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:12][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:12][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:14][V][component:205]: Components should block for at most 20-30ms. [17:59:14][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9 [17:59:14][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=18718 (now=19739) [17:59:14][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:14][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:14][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:14][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:14][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:14][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:14][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:14][V][component:205]: Components should block for at most 20-30ms. [17:59:14][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9 [17:59:14][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8) [17:59:14][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:14][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:14][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:14][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:14][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:14][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.08 s). [17:59:14][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:14][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.08 s). [17:59:14][V][component:205]: Components should block for at most 20-30ms. [17:59:14][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [17:59:14][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8) [17:59:14][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:14][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:14][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:14][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:14][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:14][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:14][V][component:205]: Components should block for at most 20-30ms. [17:59:14][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [17:59:14][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8) [17:59:14][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:14][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:14][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:14][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:14][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:14][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:14][V][component:205]: Components should block for at most 20-30ms. [17:59:14][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [17:59:15][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8) [17:59:15][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:15][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:15][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:15][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:15][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:15][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:15][V][component:205]: Components should block for at most 20-30ms. [17:59:15][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [17:59:15][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=21718 (now=22718) [17:59:15][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8) [17:59:15][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:15][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:15][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:15][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:15][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:15][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:15][V][component:205]: Components should block for at most 20-30ms. [17:59:15][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [17:59:15][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8) [17:59:15][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:15][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:15][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:15][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:15][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:15][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:15][V][component:205]: Components should block for at most 20-30ms. [17:59:15][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [17:59:15][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8) [17:59:15][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:15][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:15][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:15][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:15][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:15][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:15][V][component:205]: Components should block for at most 20-30ms. [17:59:15][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [17:59:16][VV][scheduler:032]: set_timeout(name='', timeout=0) [17:59:16][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=23612 (now=23617) [17:59:16][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8) [17:59:16][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state Meter fault [17:59:16][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'Meter fault' [17:59:16][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='Meter fault' retain=1) [17:59:16][V][sensor:043]: 'solax-meter-gateway power demand': Received new state nan [17:59:16][D][sensor:093]: 'solax-meter-gateway power demand': Sending state nan W with 0 decimals of accuracy [17:59:16][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='nan' retain=1) [17:59:16][W][solax_meter_gateway:020]: No power sensor update received since 5 seconds. Triggering meter fault for safety reasons [17:59:16][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.07 s). [17:59:16][V][component:205]: Components should block for at most 20-30ms. [17:59:16][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=22718 (now=23742) [17:59:16][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8 [17:59:16][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8)

syssi commented 1 year ago

Doofe Frage aber wie häufig wird der Stromverbrauch auf dem Topic gemeldet? Einmal pro Sekunde oder seltener?

dirk99 commented 1 year ago

Ca alle 3sek bzw. Bei jeder Anderung.

syssi commented 1 year ago

Du kannst mal versuchen diesen Parameter power_sensor_inactivity_timeout anzuheben auf 30 oder 60s. Faellt die Regelung dann seltener / nicht mehr in den "meter fault"-Modus aufgrund fehlender Daten vom Smartmeter?

dirk99 commented 1 year ago

Ich habe mittlerweile das Update vom Smartmeter auf 1sek gestellt und auch das Timeout auf 30 bzw. 60 sek. gestellt. Das Ergebnis bleibt, 5 Datensäte und dann ist Schluß. Dann kommt wieder meter_fault

syssi commented 1 year ago

Dann habe ich bei der Implementierung einen Fehler gemacht. :-) Ich schau es mir an.

syssi commented 1 year ago

Ich habe eine kleine Änderung gepusht um etwas gesprächiger im Log-Level VERY_VERBOSE zu werden:

https://github.com/syssi/esphome-solax-x1-mini/commit/da853e72442b354d9d8b095e31bb9be3bc473048

Meine Hoffnung ist so der Ursache auf die Schliche zu kommen. Einen Fehler im Code konnte ich bisher nicht ausfindig machen.

syssi commented 1 year ago

Bitte einfach den ESP noch einmal flashen. Die zusätzlichen Meldungen im Log sollten daraufhin sofort erscheinen.

dirk99 commented 1 year ago

esieht jetzt schon besser aus, aber ich musste power_sensor_inactivity_timeout auf 60 stellen. MQTT liefert jede sek, neuen Wert vom SDM72. Was mir aber aufgefallen ist, sobald ich den Solax auf Export Control "Meter" stelle und die Export Controll Value auf "20000" stehen habe liefert der Inverter kein Strom mehr. (AC power 0W). Wenn ich es richtig verstanden habe sollte bei 20000 doch keine Begrenzung statt finden oder? Im angehängten Log kannst Du noch erkenn, das ESPhome Zeitweise sie Socketverbindung zum ioBroker verliert. Könnte das das Problem sein? z.B. [11:52:55][W][api.connection:075]: 192.168.168.201: Socket operation failed: BAD_INDICATOR errno=11

INFO ESPHome 2023.5.5
INFO Reading configuration /opt/iobroker/iobroker-data/esphome.0/solaxgatewaytosmartmeter.yaml...
INFO Updating https://github.com/syssi/esphome-modbus-solax-x1.git@main
INFO Starting log output from solax-meter-gateway.local using esphome API
INFO Successfully connected to solax-meter-gateway.local
[11:52:15][I][app:102]: ESPHome version 2023.5.5 compiled on Jun  7 2023, 11:50:57
[11:52:15][I][app:104]: Project syssi.esphome-modbus-solax-x1 version 2.1.0
[11:52:15][C][wifi:505]: WiFi:
[11:52:15][C][wifi:363]:   Local MAC: E8:9F:6D:87:4D:DE
[11:52:15][C][wifi:364]:   SSID: 'home'[redacted]
[11:52:15][C][wifi:365]:   IP Address: 192.168.168.165
[11:52:15][C][wifi:366]:   BSSID: F0:9F:C2:F1:F1:5C[redacted]
[11:52:15][C][wifi:368]:   Hostname: 'solax-meter-gateway'
[11:52:15][C][wifi:370]:   Signal strength: -70 dB ▂▄▆█
[11:52:15][V][wifi:372]:   Priority: 0.0
[11:52:15][C][wifi:374]:   Channel: 11
[11:52:15][C][wifi:375]:   Subnet: 255.255.255.0
[11:52:15][C][wifi:376]:   Gateway: 192.168.168.1
[11:52:15][C][wifi:377]:   DNS1: 192.168.168.1
[11:52:15][C][wifi:378]:   DNS2: 8.8.8.8
[11:52:15][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=21770 (now=21780)
[11:52:15][C][logger:301]: Logger:
[11:52:15][C][logger:302]:   Level: VERY_VERBOSE
[11:52:15][C][logger:303]:   Log Baud Rate: 115200
[11:52:15][C][logger:305]:   Hardware UART: UART0
[11:52:15][C][uart.arduino_esp8266:102]: UART Bus:
[11:52:15][C][uart.arduino_esp8266:103]:   TX Pin: GPIO4
[11:52:15][C][uart.arduino_esp8266:104]:   RX Pin: GPIO5
[11:52:15][C][uart.arduino_esp8266:106]:   RX Buffer Size: 256
[11:52:15][C][uart.arduino_esp8266:108]:   Baud Rate: 9600 baud
[11:52:15][C][uart.arduino_esp8266:109]:   Data Bits: 8
[11:52:15][C][uart.arduino_esp8266:110]:   Parity: NONE
[11:52:15][C][uart.arduino_esp8266:111]:   Stop bits: 1
[11:52:15][C][uart.arduino_esp8266:115]:   Using software serial
[11:52:15][C][solax_meter_modbus:096]: SolaxMeterModbus:
[11:52:15][C][solax_meter_gateway:095]: SolaxMeterGateway:
[11:52:15][C][solax_meter_gateway:096]:   Address: 0x01
[11:52:15][C][solax_meter_gateway:097]:   Power Demand 'solax-meter-gateway power demand'
[11:52:15][C][solax_meter_gateway:097]:     Device Class: 'power'
[11:52:15][C][solax_meter_gateway:097]:     State Class: ''
[11:52:15][C][solax_meter_gateway:097]:     Unit of Measurement: 'W'
[11:52:15][C][solax_meter_gateway:097]:     Accuracy Decimals: 0
[11:52:15][C][solax_meter_gateway:098]:   Operation name 'solax-meter-gateway operation mode'
[11:52:15][C][solax_meter_gateway:098]:     Icon: 'mdi:heart-pulse'
[11:52:15][C][solax_meter_gateway.switch:068]: SolaxMeterGateway Switch 'solax-meter-gateway emergency power off'
[11:52:15][C][solax_meter_gateway.switch:070]:   Icon: 'mdi:power'
[11:52:15][C][solax_meter_gateway.switch:090]:   Restore Mode: restore defaults to OFF
[11:52:15][C][solax_meter_gateway.switch:052]:   Restore Mode: Restore (Defaults to OFF)
[11:52:15][C][mdns:108]: mDNS:
[11:52:15][C][mdns:109]:   Hostname: solax-meter-gateway
[11:52:15][V][mdns:110]:   Services:
[11:52:15][V][mdns:112]:   - _esphomelib, _tcp, 6053
[11:52:15][V][mdns:114]:     TXT: version = 2023.5.5
[11:52:15][V][mdns:114]:     TXT: mac = e89f6d874dde
[11:52:15][V][mdns:114]:     TXT: platform = ESP8266
[11:52:15][V][mdns:114]:     TXT: board = d1_mini
[11:52:15][V][mdns:114]:     TXT: network = wifi
[11:52:15][V][mdns:114]:     TXT: project_name = syssi.esphome-modbus-solax-x1
[11:52:15][V][mdns:114]:     TXT: project_version = 2.1.0
[11:52:15][C][ota:093]: Over-The-Air Updates:
[11:52:15][C][ota:094]:   Address: solax-meter-gateway.local:8266
[11:52:15][C][ota:097]:   Using Password.
[11:52:15][C][api:138]: API Server:
[11:52:15][C][api:139]:   Address: solax-meter-gateway.local:6053
[11:52:15][C][api:141]:   Using noise encryption: YES
[11:52:15][C][mqtt:065]: MQTT:
[11:52:15][C][mqtt:066]:   Server Address: 192.168.168.201:2884 (192.168.168.201)
[11:52:15][C][mqtt:068]:   Username: 'sonoff'[redacted]
[11:52:15][C][mqtt:069]:   Client ID: 'solax-meter-gateway-e89f6d874dde'[redacted]
[11:52:15][C][mqtt:071]:   Discovery prefix: 'homeassistant'
[11:52:15][C][mqtt:072]:   Discovery retain: YES
[11:52:15][C][mqtt:074]:   Topic Prefix: 'solax-meter-gateway'
[11:52:15][C][mqtt:076]:   Log Topic: 'VERY_VERBOSE'
[11:52:15][C][mqtt:079]:   Availability: 'solax-meter-gateway/status'
[11:52:15][C][mqtt_subscribe.sensor:031]: MQTT Subscribe 'solax-meter-gateway instantaneous power consumption'
[11:52:15][C][mqtt_subscribe.sensor:031]:   Device Class: 'power'
[11:52:15][C][mqtt_subscribe.sensor:031]:   State Class: ''
[11:52:15][C][mqtt_subscribe.sensor:031]:   Unit of Measurement: 'W'
[11:52:15][C][mqtt_subscribe.sensor:031]:   Accuracy Decimals: 2
[11:52:15][C][mqtt_subscribe.sensor:032]:   Topic: SolaxPowerControl/P_Wirk_L1
[11:52:15][C][mqtt.sensor:027]: MQTT Sensor 'solax-meter-gateway power demand':
[11:52:15][C][mqtt.sensor:031]:   State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state'
[11:52:15][C][mqtt.text_sensor:023]: MQTT Text Sensor 'solax-meter-gateway operation mode':
[11:52:15][C][mqtt.text_sensor:024]:   State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state'
[11:52:15][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=21305 (now=22317)
[11:52:15][C][mqtt.switch:041]: MQTT Switch 'solax-meter-gateway emergency power off': 
[11:52:15][C][mqtt.switch:042]:   State Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/state'
[11:52:15][C][mqtt.switch:042]:   Command Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/command'
[11:52:16][VV][scheduler:225]: Running timeout 'state' with interval=5000 last_execution=17662 (now=22662)
[11:52:16][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:16][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=22855 (now=22859)
[11:52:16][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=22305 (now=23305)
[11:52:17][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:17][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=24176 (now=24180)
[11:52:17][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=23305 (now=24310)
[11:52:18][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=24305 (now=25305)
[11:52:18][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:18][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=25473 (now=25477)
[11:52:19][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=25305 (now=26305)
[11:52:20][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8)
[11:52:20][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[11:52:20][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:20][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.02.00.00 (5)
[11:52:20][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[11:52:20][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:20][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=26836 (now=26848)
[11:52:20][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8)
[11:52:20][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[11:52:20][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:20][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.02.00.00 (5)
[11:52:20][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[11:52:20][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:20][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:20][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:20][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:20][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:20][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:20][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:20][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:20][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:20][V][component:205]: Components should block for at most 20-30ms.
[11:52:20][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:20][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=26305 (now=27313)
[11:52:20][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:20][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:20][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:20][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:20][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:20][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:20][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:20][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:20][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:20][V][component:205]: Components should block for at most 20-30ms.
[11:52:21][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:21][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:21][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:21][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:21][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:21][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:21][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:21][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:21][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:21][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:21][V][component:205]: Components should block for at most 20-30ms.
[11:52:21][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:21][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:21][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:21][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:21][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:21][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:21][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:21][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:21][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:21][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:21][V][component:205]: Components should block for at most 20-30ms.
[11:52:21][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:21][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:21][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=28139 (now=28143)
[11:52:21][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:21][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:21][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:21][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:21][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:21][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:21][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:21][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:21][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:21][V][component:205]: Components should block for at most 20-30ms.
[11:52:21][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=27305 (now=28312)
[11:52:21][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:21][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:21][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:21][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:21][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:21][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:22][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:22][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:22][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:22][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:22][V][component:205]: Components should block for at most 20-30ms.
[11:52:22][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:22][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:22][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:22][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:22][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:22][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:22][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:22][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:22][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:22][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:22][V][component:205]: Components should block for at most 20-30ms.
[11:52:22][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:22][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:22][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:22][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:22][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:22][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:22][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:22][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:22][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:22][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:22][V][component:205]: Components should block for at most 20-30ms.
[11:52:22][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:22][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:22][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:22][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:22][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:22][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:22][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:22][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:22][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:22][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:22][V][component:205]: Components should block for at most 20-30ms.
[11:52:22][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=28305 (now=29389)
[11:52:22][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:22][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=29407 (now=29413)
[11:52:22][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:23][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:23][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:23][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:23][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:23][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:23][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:23][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:23][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:23][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:23][V][component:205]: Components should block for at most 20-30ms.
[11:52:23][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:23][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:23][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:23][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:23][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:23][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:23][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:23][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:23][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:23][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:23][V][component:205]: Components should block for at most 20-30ms.
[11:52:23][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:23][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:23][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:23][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:23][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:23][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:23][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:23][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:23][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:23][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:23][V][component:205]: Components should block for at most 20-30ms.
[11:52:23][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:23][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=29305 (now=30305)
[11:52:23][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:23][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:23][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:23][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:23][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:23][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:23][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:23][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:23][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:23][V][component:205]: Components should block for at most 20-30ms.
[11:52:23][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:24][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:24][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:24][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:24][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:24][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:24][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:24][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:24][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:24][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:24][V][component:205]: Components should block for at most 20-30ms.
[11:52:24][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:24][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=30734 (now=30738)
[11:52:24][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:24][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:24][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:24][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:24][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:24][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:24][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:24][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:24][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:24][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:24][V][component:205]: Components should block for at most 20-30ms.
[11:52:24][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:24][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:24][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:24][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:24][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:24][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:24][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:24][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:24][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:24][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:24][V][component:205]: Components should block for at most 20-30ms.
[11:52:24][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:24][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=30305 (now=31313)
[11:52:24][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:24][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:24][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:24][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:24][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:24][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:24][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:24][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:25][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:25][V][component:205]: Components should block for at most 20-30ms.
[11:52:25][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:25][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:25][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:25][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:25][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:25][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:25][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:25][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:25][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:25][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:25][V][component:205]: Components should block for at most 20-30ms.
[11:52:25][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:25][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:25][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:25][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:25][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:25][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:25][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:25][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:25][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:25][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:25][V][component:205]: Components should block for at most 20-30ms.
[11:52:25][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=32062 (now=32083)
[11:52:25][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:25][D][api:102]: Accepted 192.168.168.201
[11:52:25][VV][api.socket:214]: 192.168.168.201: Bad indicator byte 0
[11:52:25][W][api.connection:075]: 192.168.168.201: Socket operation failed: BAD_INDICATOR errno=11
[11:52:25][V][api:114]: Removing connection to 192.168.168.201
[11:52:25][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:25][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:25][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:25][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:25][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:25][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:25][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:25][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:25][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:25][V][component:205]: Components should block for at most 20-30ms.
[11:52:25][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=31305 (now=32357)
[11:52:25][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:25][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:25][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:26][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:26][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:26][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:26][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:26][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:26][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:26][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:26][V][component:205]: Components should block for at most 20-30ms.
[11:52:26][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:26][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:26][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:26][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:26][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:26][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:26][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:26][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:26][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:26][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:26][V][component:205]: Components should block for at most 20-30ms.
[11:52:26][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:26][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:26][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:26][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:26][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:26][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:26][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:26][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:26][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:26][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:26][V][component:205]: Components should block for at most 20-30ms.
[11:52:26][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:26][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:26][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:26][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:26][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:26][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:26][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:26][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:26][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:26][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:26][V][component:205]: Components should block for at most 20-30ms.
[11:52:26][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=32305 (now=33418)
[11:52:26][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=33357 (now=33418)
[11:52:26][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:27][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:27][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:27][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:27][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:27][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:27][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:27][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:27][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:27][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:27][V][component:205]: Components should block for at most 20-30ms.
[11:52:27][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:27][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:27][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:27][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:27][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:27][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:27][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:27][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:27][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:27][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:27][V][component:205]: Components should block for at most 20-30ms.
[11:52:27][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:27][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:27][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:27][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:27][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:27][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:27][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:27][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:27][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:27][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:27][V][component:205]: Components should block for at most 20-30ms.
[11:52:27][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:27][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=33305 (now=34306)
[11:52:27][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:27][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:27][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:27][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:27][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:27][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:27][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:27][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:27][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:27][V][component:205]: Components should block for at most 20-30ms.
[11:52:28][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:28][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:28][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:28][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:28][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:28][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:28][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:28][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:28][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:28][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:28][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:28][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:28][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:28][V][component:205]: Components should block for at most 20-30ms.
[11:52:28][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=34670 (now=34772)
[11:52:28][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:28][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:28][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:28][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:28][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:28][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:28][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:28][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:28][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:28][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:28][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:28][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:28][V][component:205]: Components should block for at most 20-30ms.
[11:52:28][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:28][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:28][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:28][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:28][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:28][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:28][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:28][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:28][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:28][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:28][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:28][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:28][V][component:205]: Components should block for at most 20-30ms.
[11:52:28][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=34305 (now=35308)
[11:52:28][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:28][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:28][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:28][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:28][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:28][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:28][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:29][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:29][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:29][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:29][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:29][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:29][V][component:205]: Components should block for at most 20-30ms.
[11:52:29][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:29][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:29][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:29][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:29][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:29][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:29][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:29][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:29][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:29][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:29][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:29][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:29][V][component:205]: Components should block for at most 20-30ms.
[11:52:29][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:29][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:29][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=35997 (now=36002)
[11:52:29][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:29][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:29][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:29][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:29][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:29][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:29][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:29][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:29][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:29][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:29][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:29][V][component:205]: Components should block for at most 20-30ms.
[11:52:29][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:29][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:29][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:29][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:29][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:29][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:29][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:29][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:29][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:29][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:29][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:29][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:29][V][component:205]: Components should block for at most 20-30ms.
[11:52:29][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=35305 (now=36376)
[11:52:29][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:30][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:30][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:30][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:30][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:30][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:30][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:30][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:30][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:30][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:30][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:30][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:30][V][component:205]: Components should block for at most 20-30ms.
[11:52:30][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:30][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:30][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:30][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:30][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:30][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:30][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:30][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:30][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:30][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:30][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:30][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:30][V][component:205]: Components should block for at most 20-30ms.
[11:52:30][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:30][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:30][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:30][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:30][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:30][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:30][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:30][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:30][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:30][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:30][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:30][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:30][V][component:205]: Components should block for at most 20-30ms.
[11:52:30][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:30][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=36305 (now=37305)
[11:52:30][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:30][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=37318 (now=37322)
[11:52:30][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:30][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:30][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:30][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:30][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:30][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:30][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:30][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:30][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:30][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:30][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:30][V][component:205]: Components should block for at most 20-30ms.
[11:52:30][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:31][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:31][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:31][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:31][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:31][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:31][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:31][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:31][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:31][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:31][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:31][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:31][V][component:205]: Components should block for at most 20-30ms.
[11:52:31][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:31][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:31][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:31][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:31][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:31][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:31][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:31][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:31][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:31][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:31][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:31][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:31][V][component:205]: Components should block for at most 20-30ms.
[11:52:31][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:31][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:31][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:31][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:31][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:31][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:31][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:31][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:31][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:31][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:31][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:31][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:31][V][component:205]: Components should block for at most 20-30ms.
[11:52:31][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:31][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=37305 (now=38313)
[11:52:31][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:31][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:31][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:31][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:31][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:31][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:31][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:31][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:31][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:31][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:32][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:32][V][component:205]: Components should block for at most 20-30ms.
[11:52:32][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:32][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:32][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=38617 (now=38621)
[11:52:32][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:32][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:32][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:32][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:32][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:32][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:32][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:32][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:32][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:32][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:32][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:32][V][component:205]: Components should block for at most 20-30ms.
[11:52:32][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:32][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:32][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:32][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:32][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:32][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:32][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:32][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:32][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:32][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:32][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:32][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:32][V][component:205]: Components should block for at most 20-30ms.
[11:52:32][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:32][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:32][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:32][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:32][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:32][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:32][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:32][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:32][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:32][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:32][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:32][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:32][V][component:205]: Components should block for at most 20-30ms.
[11:52:32][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=38305 (now=39335)
[11:52:32][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:32][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:32][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:33][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:33][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:33][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:33][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:33][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:33][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:33][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:33][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:33][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:33][V][component:205]: Components should block for at most 20-30ms.
[11:52:33][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:33][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:33][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:33][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:33][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:33][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:33][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:33][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:33][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:33][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:33][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:33][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:33][V][component:205]: Components should block for at most 20-30ms.
[11:52:33][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:33][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:33][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=39955 (now=39960)
[11:52:33][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:33][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:33][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:33][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:33][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:33][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:33][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:33][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:33][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:33][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:33][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:33][V][component:205]: Components should block for at most 20-30ms.
[11:52:33][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:33][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:33][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:33][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:33][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:33][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:33][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:33][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:33][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:33][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:33][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:33][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:33][V][component:205]: Components should block for at most 20-30ms.
[11:52:33][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=39305 (now=40413)
[11:52:33][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:34][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[11:52:34][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[11:52:34][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:34][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[11:52:34][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
[11:52:34][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[11:52:34][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[11:52:34][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:34][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[11:52:34][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
[11:52:34][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[11:52:34][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[11:52:34][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:34][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[11:52:34][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
[11:52:34][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:34][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=41268 (now=41272)
[11:52:34][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=40305 (now=41305)
[11:52:34][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:34][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:34][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:34][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:34][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:34][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:34][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:34][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:34][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:34][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:34][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:34][V][component:205]: Components should block for at most 20-30ms.
[11:52:34][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:35][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:35][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:35][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:35][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:35][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:35][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:35][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:35][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:35][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:35][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:35][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:35][V][component:205]: Components should block for at most 20-30ms.
[11:52:35][VV][api.service:512]: on_ping_request: PingRequest {}
[11:52:35][VV][api.service:043]: send_ping_response: PingResponse {}
[11:52:35][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:35][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:35][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:35][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:35][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:35][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:35][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:35][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:35][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:35][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:35][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:35][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:35][V][component:205]: Components should block for at most 20-30ms.
[11:52:35][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:35][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:35][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:35][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:35][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:35][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:35][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:35][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:35][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:35][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:35][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:35][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:35][V][component:205]: Components should block for at most 20-30ms.
[11:52:35][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=41305 (now=42306)
[11:52:35][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:35][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:35][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:35][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:35][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:35][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:35][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:36][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:36][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:36][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:36][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:36][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:36][V][component:205]: Components should block for at most 20-30ms.
[11:52:36][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=42529 (now=42588)
[11:52:36][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:36][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:36][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:36][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:36][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:36][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:36][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:36][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:36][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:36][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:36][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:36][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:36][V][component:205]: Components should block for at most 20-30ms.
[11:52:36][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:36][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:36][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:36][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:36][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:36][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:36][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:36][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:36][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:36][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:36][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:36][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:36][V][component:205]: Components should block for at most 20-30ms.
[11:52:36][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:36][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:36][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:36][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:36][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:36][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:36][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:36][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:36][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:36][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:36][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:36][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:36][V][component:205]: Components should block for at most 20-30ms.
[11:52:36][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=42305 (now=43386)
[11:52:36][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:37][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:37][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:37][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:37][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:37][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:37][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:37][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:37][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:37][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:37][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:37][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:37][V][component:205]: Components should block for at most 20-30ms.
[11:52:37][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:37][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:37][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:37][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:37][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:37][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:37][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:37][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:37][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:37][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:37][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:37][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:37][V][component:205]: Components should block for at most 20-30ms.
[11:52:37][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=43813 (now=43922)
[11:52:37][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:37][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:37][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:37][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:37][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:37][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:37][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:37][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:37][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:37][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:37][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:37][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:37][V][component:205]: Components should block for at most 20-30ms.
[11:52:37][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:37][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=43305 (now=44309)
[11:52:37][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:37][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:37][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:37][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:37][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:37][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:37][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:37][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:37][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:37][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:37][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:37][V][component:205]: Components should block for at most 20-30ms.
[11:52:37][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:38][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:38][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:38][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:38][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:38][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:38][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:38][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:38][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:38][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:38][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:38][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:38][V][component:205]: Components should block for at most 20-30ms.
[11:52:38][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:38][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:38][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:38][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:38][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:38][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:38][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:38][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:38][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:38][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:38][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:38][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:38][V][component:205]: Components should block for at most 20-30ms.
[11:52:38][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:38][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:38][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:38][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:38][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:38][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:38][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:38][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:38][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:38][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:38][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:38][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:38][V][component:205]: Components should block for at most 20-30ms.
[11:52:38][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=45158 (now=45265)
[11:52:38][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:38][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=44305 (now=45309)
[11:52:38][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:38][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:38][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:38][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:38][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:38][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:38][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:38][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:38][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:38][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:38][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:38][V][component:205]: Components should block for at most 20-30ms.
[11:52:39][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:39][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:39][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:39][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:39][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:39][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:39][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:39][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:39][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:39][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:39][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:39][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:39][V][component:205]: Components should block for at most 20-30ms.
[11:52:39][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:39][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:39][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:39][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:39][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:39][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:39][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:39][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:39][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:39][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:39][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:39][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:39][V][component:205]: Components should block for at most 20-30ms.
[11:52:39][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:39][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:39][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:39][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:39][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:39][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:39][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:39][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:39][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:39][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:39][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:39][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:39][V][component:205]: Components should block for at most 20-30ms.
[11:52:39][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=45305 (now=46332)
[11:52:39][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:39][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:39][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=46465 (now=46470)
[11:52:39][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:39][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:40][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:40][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:40][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:40][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:40][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:40][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:40][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:40][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:40][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:40][V][component:205]: Components should block for at most 20-30ms.
[11:52:40][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:40][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:40][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:40][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:40][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:40][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:40][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:40][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:40][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:40][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:40][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:40][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:40][V][component:205]: Components should block for at most 20-30ms.
[11:52:40][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:40][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:40][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:40][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:40][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:40][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:40][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:40][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:40][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:40][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:40][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:40][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:40][V][component:205]: Components should block for at most 20-30ms.
[11:52:40][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:40][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:40][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:40][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:40][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:40][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:40][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:40][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:40][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:40][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:40][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:40][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:40][V][component:205]: Components should block for at most 20-30ms.
[11:52:40][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=46305 (now=47407)
[11:52:40][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:41][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:41][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:41][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:41][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:41][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:41][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:41][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:41][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:41][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:41][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:41][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:41][V][component:205]: Components should block for at most 20-30ms.
[11:52:41][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:41][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:41][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=47779 (now=47784)
[11:52:41][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:41][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:41][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:41][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:41][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:41][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:41][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:41][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:41][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:41][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:41][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:41][V][component:205]: Components should block for at most 20-30ms.
[11:52:41][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:41][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:41][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:41][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:41][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:41][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:41][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:41][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:41][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:41][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:41][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:41][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:41][V][component:205]: Components should block for at most 20-30ms.
[11:52:41][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:41][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=47305 (now=48305)
[11:52:41][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:41][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:41][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:41][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:41][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:41][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:41][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:41][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:41][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:41][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:41][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:41][V][component:205]: Components should block for at most 20-30ms.
[11:52:41][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:42][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:42][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:42][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:42][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:42][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:42][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:42][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:42][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:42][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:42][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:42][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:42][V][component:205]: Components should block for at most 20-30ms.
[11:52:42][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:42][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:42][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:42][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:42][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:42][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:42][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:42][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:42][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:42][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:42][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:42][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:42][V][component:205]: Components should block for at most 20-30ms.
[11:52:42][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:42][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:42][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=49056 (now=49077)
[11:52:42][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:42][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:42][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:42][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:42][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:42][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:42][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:42][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:42][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:42][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:42][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:42][V][component:205]: Components should block for at most 20-30ms.
[11:52:42][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=48305 (now=49305)
[11:52:42][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:42][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:42][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:42][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:42][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:42][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:42][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:42][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:42][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:43][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:43][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:43][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:43][V][component:205]: Components should block for at most 20-30ms.
[11:52:43][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:43][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:43][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:43][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:43][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:43][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:43][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:43][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:43][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:43][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:43][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:43][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:43][V][component:205]: Components should block for at most 20-30ms.
[11:52:43][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:43][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:43][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:43][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:43][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:43][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:43][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:43][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:43][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:43][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:43][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:43][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:43][V][component:205]: Components should block for at most 20-30ms.
[11:52:43][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:43][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:43][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:43][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:43][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:43][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:43][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:43][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:43][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:43][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:43][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:43][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:43][V][component:205]: Components should block for at most 20-30ms.
[11:52:43][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=49305 (now=50365)
[11:52:43][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:43][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=50376 (now=50380)
[11:52:43][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:44][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:44][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:44][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:44][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:44][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:44][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:44][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:44][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:44][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:44][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:44][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:44][V][component:205]: Components should block for at most 20-30ms.
[11:52:44][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:44][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:44][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:44][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:44][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:44][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:44][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:44][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:44][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:44][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:44][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:44][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:44][V][component:205]: Components should block for at most 20-30ms.
[11:52:44][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:44][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:44][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:44][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:44][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:44][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:44][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:44][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:44][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:44][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:44][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:44][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:44][V][component:205]: Components should block for at most 20-30ms.
[11:52:44][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:44][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=50305 (now=51305)
[11:52:44][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:44][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:44][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:44][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:44][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:44][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:44][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:44][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:44][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:44][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:44][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:44][V][component:205]: Components should block for at most 20-30ms.
[11:52:44][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:45][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:45][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:45][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:45][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:45][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:45][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:45][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:45][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:45][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:45][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:45][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:45][V][component:205]: Components should block for at most 20-30ms.
[11:52:45][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=51688 (now=51718)
[11:52:45][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:45][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:45][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:45][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:45][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:45][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:45][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:45][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:45][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:45][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:45][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:45][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:45][V][component:205]: Components should block for at most 20-30ms.
[11:52:45][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:45][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:45][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:45][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:45][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:45][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:45][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:45][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:45][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:45][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:45][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:45][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:45][V][component:205]: Components should block for at most 20-30ms.
[11:52:45][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:45][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=51305 (now=52307)
[11:52:45][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:45][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:45][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:45][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:45][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:45][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:45][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:45][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:45][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:45][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:45][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:45][V][component:205]: Components should block for at most 20-30ms.
[11:52:46][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:46][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:46][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:46][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:46][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:46][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:46][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:46][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:46][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:46][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:46][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:46][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:46][V][component:205]: Components should block for at most 20-30ms.
[11:52:46][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:46][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:46][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:46][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:46][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:46][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:46][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:46][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:46][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:46][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:46][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:46][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:46][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:46][V][component:205]: Components should block for at most 20-30ms.
[11:52:46][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=52966 (now=53067)
[11:52:46][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:46][VV][scheduler:225]: Running interval '' with interval=60000 last_execution=4294960400 (now=53110)
[11:52:46][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:46][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:46][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:46][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:46][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:46][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:46][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:46][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:46][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:46][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:46][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:46][V][component:205]: Components should block for at most 20-30ms.
[11:52:46][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=52305 (now=53328)
[11:52:46][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:46][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:46][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:46][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:47][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:47][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:47][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:47][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:47][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:47][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:47][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:47][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:47][V][component:205]: Components should block for at most 20-30ms.
[11:52:47][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:47][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:47][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:47][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:47][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:47][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:47][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:47][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:47][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:47][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:47][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:47][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:47][V][component:205]: Components should block for at most 20-30ms.
[11:52:47][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:47][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:47][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:47][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:47][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:47][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:47][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:47][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:47][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:47][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:47][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:47][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:47][V][component:205]: Components should block for at most 20-30ms.
[11:52:47][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:47][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:47][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:47][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:47][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:47][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:47][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:47][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:47][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:47][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:47][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:47][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:47][V][component:205]: Components should block for at most 20-30ms.
[11:52:47][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=53305 (now=54413)
[11:52:47][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=54312 (now=54413)
[11:52:47][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:48][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:48][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:48][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:48][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:48][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:48][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:48][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:48][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:48][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:48][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:48][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:48][V][component:205]: Components should block for at most 20-30ms.
[11:52:48][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:48][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[11:52:48][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[11:52:48][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:48][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[11:52:48][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
[11:52:48][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[11:52:48][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[11:52:48][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:48][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[11:52:48][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
[11:52:48][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=54305 (now=55310)
[11:52:48][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[11:52:48][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[11:52:48][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:48][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[11:52:48][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
[11:52:49][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:49][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=55591 (now=55595)
[11:52:49][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:49][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:49][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:49][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:49][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:49][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:49][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:49][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:49][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:49][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:49][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:49][V][component:205]: Components should block for at most 20-30ms.
[11:52:49][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:49][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:49][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:49][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:49][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:49][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:49][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:49][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:49][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:49][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:49][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:49][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:49][V][component:205]: Components should block for at most 20-30ms.
[11:52:49][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:49][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:49][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:49][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:49][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:49][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:49][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:49][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:49][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:49][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:49][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:49][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:49][V][component:205]: Components should block for at most 20-30ms.
[11:52:49][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=55305 (now=56306)
[11:52:49][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:49][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:49][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:49][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:49][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:49][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:49][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:49][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:49][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:49][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:50][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:50][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:50][V][component:205]: Components should block for at most 20-30ms.
[11:52:50][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:50][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:50][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:50][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:50][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:50][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:50][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:50][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:50][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:50][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:50][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:50][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:50][V][component:205]: Components should block for at most 20-30ms.
[11:52:50][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:50][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:50][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=56978 (now=56982)
[11:52:50][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:50][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:50][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:50][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:50][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:50][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:50][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:50][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:50][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:50][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:50][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:50][V][component:205]: Components should block for at most 20-30ms.
[11:52:50][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:50][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:50][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:50][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:50][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:50][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:50][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:50][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:50][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:50][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:50][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:50][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:50][V][component:205]: Components should block for at most 20-30ms.
[11:52:50][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=56305 (now=57358)
[11:52:50][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:50][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:51][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:51][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:51][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:51][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:51][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:51][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:51][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:51][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:51][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:51][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:51][V][component:205]: Components should block for at most 20-30ms.
[11:52:51][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:51][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:51][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:51][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:51][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:51][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:51][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:51][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:51][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:51][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:51][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:51][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:51][V][component:205]: Components should block for at most 20-30ms.
[11:52:51][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:51][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:51][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:51][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:51][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:51][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:51][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:51][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:51][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:51][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:51][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:51][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:51][V][component:205]: Components should block for at most 20-30ms.
[11:52:51][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:51][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:51][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=58223 (now=58227)
[11:52:51][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=57305 (now=58305)
[11:52:51][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:51][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:51][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:51][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:51][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:51][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:51][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:51][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:51][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:51][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:51][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:51][V][component:205]: Components should block for at most 20-30ms.
[11:52:51][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:52][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:52][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:52][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:52][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:52][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:52][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:52][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:52][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:52][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:52][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:52][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:52][V][component:205]: Components should block for at most 20-30ms.
[11:52:52][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:52][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:52][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:52][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:52][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:52][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:52][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:52][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:52][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:52][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:52][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:52][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:52][V][component:205]: Components should block for at most 20-30ms.
[11:52:52][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:52][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:52][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:52][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:52][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:52][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:52][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:52][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:52][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:52][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:52][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:52][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:52][V][component:205]: Components should block for at most 20-30ms.
[11:52:52][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:52][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=58305 (now=59310)
[11:52:52][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:52][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:52][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:52][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:52][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:52][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:52][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:52][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:52][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:52][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:52][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:52][V][component:205]: Components should block for at most 20-30ms.
[11:52:53][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:53][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=59526 (now=59530)
[11:52:53][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:53][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:53][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:53][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:53][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:53][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:53][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:53][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:53][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:53][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:53][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:53][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:53][V][component:205]: Components should block for at most 20-30ms.
[11:52:53][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:53][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:53][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:53][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:53][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:53][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:53][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:53][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:53][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:53][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:53][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:53][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:53][V][component:205]: Components should block for at most 20-30ms.
[11:52:53][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:53][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:53][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:53][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:53][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:53][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:53][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:53][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:53][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:53][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:53][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:53][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:53][V][component:205]: Components should block for at most 20-30ms.
[11:52:53][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=59305 (now=60320)
[11:52:53][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:53][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:53][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:54][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:54][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:54][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:54][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:54][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:54][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:54][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:54][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:54][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:54][V][component:205]: Components should block for at most 20-30ms.
[11:52:54][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:54][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:54][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:54][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:54][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:54][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:54][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:54][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:54][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:54][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:54][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:54][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:54][V][component:205]: Components should block for at most 20-30ms.
[11:52:54][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=60842 (now=60863)
[11:52:54][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:54][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:54][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:54][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:54][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:54][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:54][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:54][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:54][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:54][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:54][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:54][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:54][V][component:205]: Components should block for at most 20-30ms.
[11:52:54][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:54][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:54][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:54][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:54][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:54][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:54][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:54][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:54][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:54][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:54][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:54][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:54][V][component:205]: Components should block for at most 20-30ms.
[11:52:54][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=60305 (now=61399)
[11:52:54][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:55][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:55][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:55][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:55][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:55][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:55][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:55][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:55][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:55][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:55][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:55][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:55][V][component:205]: Components should block for at most 20-30ms.
[11:52:55][VV][api.service:512]: on_ping_request: PingRequest {}
[11:52:55][VV][api.service:043]: send_ping_response: PingResponse {}
[11:52:55][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:55][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:55][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:55][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:55][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:55][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:55][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:55][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:55][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:55][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:55][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:55][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:55][V][component:205]: Components should block for at most 20-30ms.
[11:52:55][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:55][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:55][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:55][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:55][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:55][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:55][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:55][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:55][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:55][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:55][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:55][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:55][V][component:205]: Components should block for at most 20-30ms.
[11:52:55][D][api:102]: Accepted 192.168.168.201
[11:52:55][VV][api.socket:214]: 192.168.168.201: Bad indicator byte 0
[11:52:55][W][api.connection:075]: 192.168.168.201: Socket operation failed: BAD_INDICATOR errno=11
[11:52:55][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=62155 (now=62231)
[11:52:55][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:55][V][api:114]: Removing connection to 192.168.168.201
[11:52:55][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=61305 (now=62311)
[11:52:55][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:55][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:55][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:55][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:55][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:55][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:55][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:55][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:55][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:55][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:55][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:55][V][component:205]: Components should block for at most 20-30ms.
[11:52:55][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:56][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:56][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:56][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:56][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:56][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:56][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:56][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:56][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:56][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:56][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:56][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:56][V][component:205]: Components should block for at most 20-30ms.
[11:52:56][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:56][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:56][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:56][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:56][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:56][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:56][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:56][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:56][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:56][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:56][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:56][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:56][V][component:205]: Components should block for at most 20-30ms.
[11:52:56][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:56][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:56][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:56][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:56][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:56][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:56][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:56][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:56][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:56][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:56][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:56][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:56][V][component:205]: Components should block for at most 20-30ms.
[11:52:56][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=62305 (now=63305)
[11:52:56][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:56][VV][scheduler:032]: set_timeout(name='', timeout=0)
[11:52:56][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=63439 (now=63443)
[11:52:56][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:56][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:56][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:56][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:56][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:57][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:57][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:57][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:57][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:57][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:57][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:57][V][component:205]: Components should block for at most 20-30ms.
[11:52:57][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:57][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:57][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:57][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:57][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:57][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:57][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:57][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:57][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:57][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:57][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:57][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[11:52:57][V][component:205]: Components should block for at most 20-30ms.
[11:52:57][D][uart_debug:114]: >>> 01:03:02:05:A9:7B:6A
[11:52:57][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[11:52:57][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[11:52:57][VV][uart.arduino_esp8266:180]:     Flushing...
[11:52:57][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.05.A9.7B.6A (7)
[11:52:57][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 1449.729980
[11:52:57][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 1449.72998 W with 0 decimals of accuracy
[11:52:57][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='1450' retain=1)
[11:52:57][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[11:52:57][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[11:52:57][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[11:52:57][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
syssi commented 1 year ago
[11:52:25][W][api.connection:075]: 192.168.168.201: Socket operation failed: BAD_INDICATOR errno=11

Hier geht es um die native API, welche normalerweise nur von Home Assistant oder ESPHome selbst genutzt wird. Gibt es auf dem Host 192.168.168.201 etwas in der Richtung? Der BAD_INDICATOR-Fehler tritt in der Regel auf, wenn man einen API-Schlüssel verwendet der nicht zur YAML-Konfiguration passt. Vermutlich kannst du diese Zeile ignorieren.

syssi commented 1 year ago
[17:59:08][I][app:102]: ESPHome version 2023.5.5 compiled on Jun 6 2023, 17:54:47

Kannst du die Node einmal neu flashen, so dass die Änderung von heute Morgen mit auf den ESP kommt?

dirk99 commented 1 year ago

Ja, auf dem iobroker ist das Esphome Modul installiert. Das nutzte ich zur Konfiguration, logging, etc.

dirk99 commented 1 year ago

Welche Version muss denn angezeigt werden? Ich hatte ihn neu geflasht.

syssi commented 1 year ago

Was mir aber aufgefallen ist, sobald ich den Solax auf Export Control "Meter" stelle und die Export Controll Value auf "20000" stehen habe liefert der Inverter kein Strom mehr. (AC power 0W). Wenn ich es richtig verstanden habe sollte bei 20000 doch keine Begrenzung statt finden oder?

Ich kenne dazu nur diese Erklaerung, welche aber nicht zu deiner Beobachtung passt:

https://github.com/syssi/esphome-solax-x1-mini/issues/20#issuecomment-1086832787

Hier wird beschrieben, dass man über diesen Wert den Export an das Stromnetz steuert. Steht die Einstellung auf "0 Watt", dann wird versucht keine Energie an den Netzbetreiber zu exportieren. Setzt du es auf "20k" haette ich erwartet, dass im worst-case 20kW in Netz rückgespeist werden.

syssi commented 1 year ago

Welche Version muss denn angezeigt werden? Ich hatte ihn neu geflasht

An dem Zeitstempel (compile time) aus dem Log habe ich nur abgelesehen, dass du zuletzt gestern um 17:54 Uhr geflasht hast:

[17:59:08][I][app:102]: ESPHome version 2023.5.5 compiled on Jun 6 2023, 17:54:47

dirk99 commented 1 year ago

Genau so habe ich die Doku verstanden... Hmmm

dirk99 commented 1 year ago

Ich habe gerade mal wieder ein Log gezogen. Was mir aber auffällt ist, dass immer der wert Received new state 411.989990 empfangen wird, obwohl der MQTT wird sich sekündlich ändert. Sobald ich Power Meter einschalte, geht die Erzeugung zurück auf 0W

INFO ESPHome 2023.5.5
INFO Reading configuration /opt/iobroker/iobroker-data/esphome.0/solaxgatewaytosmartmeter.yaml...
INFO Updating https://github.com/syssi/esphome-modbus-solax-x1.git@main
INFO Starting log output from solax-meter-gateway.local using esphome API
INFO Successfully connected to solax-meter-gateway.local
[18:01:11][I][app:102]: ESPHome version 2023.5.5 compiled on Jun  7 2023, 11:50:57
[18:01:11][I][app:104]: Project syssi.esphome-modbus-solax-x1 version 2.1.0
[18:01:11][C][wifi:505]: WiFi:
[18:01:11][C][wifi:363]:   Local MAC: E8:9F:6D:87:4D:DE
[18:01:11][C][wifi:364]:   SSID: 'home'[redacted]
[18:01:11][C][wifi:365]:   IP Address: 192.168.168.165
[18:01:11][C][wifi:366]:   BSSID: F0:9F:C2:F1:F1:5C[redacted]
[18:01:11][C][wifi:368]:   Hostname: 'solax-meter-gateway'
[18:01:11][C][wifi:370]:   Signal strength: -68 dB ▂▄▆█
[18:01:11][V][wifi:372]:   Priority: 0.0
[18:01:11][C][wifi:374]:   Channel: 11
[18:01:11][C][wifi:375]:   Subnet: 255.255.255.0
[18:01:11][C][wifi:376]:   Gateway: 192.168.168.1
[18:01:11][C][wifi:377]:   DNS1: 192.168.168.1
[18:01:11][C][wifi:378]:   DNS2: 8.8.8.8
[18:01:11][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=11954 (now=13105)
[18:01:11][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:11][C][logger:301]: Logger:
[18:01:11][C][logger:302]:   Level: VERY_VERBOSE
[18:01:11][C][logger:303]:   Log Baud Rate: 115200
[18:01:11][C][logger:305]:   Hardware UART: UART0
[18:01:11][VV][scheduler:032]: set_timeout(name='', timeout=0)
[18:01:11][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=13167 (now=13172)
[18:01:11][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:11][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:11][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:11][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:11][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:11][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:11][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:11][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:11][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:11][V][component:205]: Components should block for at most 20-30ms.
[18:01:12][C][uart.arduino_esp8266:102]: UART Bus:
[18:01:12][C][uart.arduino_esp8266:103]:   TX Pin: GPIO4
[18:01:12][C][uart.arduino_esp8266:104]:   RX Pin: GPIO5
[18:01:12][C][uart.arduino_esp8266:106]:   RX Buffer Size: 256
[18:01:12][C][uart.arduino_esp8266:108]:   Baud Rate: 9600 baud
[18:01:12][C][uart.arduino_esp8266:109]:   Data Bits: 8
[18:01:12][C][uart.arduino_esp8266:110]:   Parity: NONE
[18:01:12][C][uart.arduino_esp8266:111]:   Stop bits: 1
[18:01:12][C][uart.arduino_esp8266:115]:   Using software serial
[18:01:12][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:12][C][solax_meter_modbus:096]: SolaxMeterModbus:
[18:01:12][C][solax_meter_gateway:095]: SolaxMeterGateway:
[18:01:12][C][solax_meter_gateway:096]:   Address: 0x01
[18:01:12][C][solax_meter_gateway:097]:   Power Demand 'solax-meter-gateway power demand'
[18:01:12][C][solax_meter_gateway:097]:     Device Class: 'power'
[18:01:12][C][solax_meter_gateway:097]:     State Class: ''
[18:01:12][C][solax_meter_gateway:097]:     Unit of Measurement: 'W'
[18:01:12][C][solax_meter_gateway:097]:     Accuracy Decimals: 0
[18:01:12][C][solax_meter_gateway:098]:   Operation name 'solax-meter-gateway operation mode'
[18:01:12][C][solax_meter_gateway:098]:     Icon: 'mdi:heart-pulse'
[18:01:12][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:12][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:12][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:12][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:12][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:12][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:12][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:12][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:12][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:12][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:12][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:12][V][component:205]: Components should block for at most 20-30ms.
[18:01:12][C][solax_meter_gateway.switch:068]: SolaxMeterGateway Switch 'solax-meter-gateway emergency power off'
[18:01:12][C][solax_meter_gateway.switch:070]:   Icon: 'mdi:power'
[18:01:12][C][solax_meter_gateway.switch:090]:   Restore Mode: restore defaults to OFF
[18:01:12][C][solax_meter_gateway.switch:052]:   Restore Mode: Restore (Defaults to OFF)
[18:01:12][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:12][C][mdns:108]: mDNS:
[18:01:12][C][mdns:109]:   Hostname: solax-meter-gateway
[18:01:12][V][mdns:110]:   Services:
[18:01:12][V][mdns:112]:   - _esphomelib, _tcp, 6053
[18:01:12][V][mdns:114]:     TXT: version = 2023.5.5
[18:01:12][V][mdns:114]:     TXT: mac = e89f6d874dde
[18:01:12][V][mdns:114]:     TXT: platform = ESP8266
[18:01:12][V][mdns:114]:     TXT: board = d1_mini
[18:01:12][V][mdns:114]:     TXT: network = wifi
[18:01:12][V][mdns:114]:     TXT: project_name = syssi.esphome-modbus-solax-x1
[18:01:12][V][mdns:114]:     TXT: project_version = 2.1.0
[18:01:12][VV][scheduler:225]: Running timeout 'state' with interval=5000 last_execution=8607 (now=13675)
[18:01:12][C][ota:093]: Over-The-Air Updates:
[18:01:12][C][ota:094]:   Address: solax-meter-gateway.local:8266
[18:01:12][C][ota:097]:   Using Password.
[18:01:12][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:12][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:12][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:12][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:12][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:12][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:12][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:12][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:12][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:12][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:12][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:12][V][component:205]: Components should block for at most 20-30ms.
[18:01:12][C][api:138]: API Server:
[18:01:12][C][api:139]:   Address: solax-meter-gateway.local:6053
[18:01:12][C][api:141]:   Using noise encryption: YES
[18:01:12][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:12][C][mqtt:065]: MQTT:
[18:01:12][C][mqtt:066]:   Server Address: 192.168.168.201:2884 (192.168.168.201)
[18:01:12][C][mqtt:068]:   Username: 'sonoff'[redacted]
[18:01:12][C][mqtt:069]:   Client ID: 'solax-meter-gateway-e89f6d874dde'[redacted]
[18:01:12][C][mqtt:071]:   Discovery prefix: 'homeassistant'
[18:01:12][C][mqtt:072]:   Discovery retain: YES
[18:01:12][C][mqtt:074]:   Topic Prefix: 'solax-meter-gateway'
[18:01:12][C][mqtt:076]:   Log Topic: 'VERY_VERBOSE'
[18:01:12][C][mqtt:079]:   Availability: 'solax-meter-gateway/status'
[18:01:12][C][mqtt_subscribe.sensor:031]: MQTT Subscribe 'solax-meter-gateway instantaneous power consumption'
[18:01:12][C][mqtt_subscribe.sensor:031]:   Device Class: 'power'
[18:01:12][C][mqtt_subscribe.sensor:031]:   State Class: ''
[18:01:12][C][mqtt_subscribe.sensor:031]:   Unit of Measurement: 'W'
[18:01:12][C][mqtt_subscribe.sensor:031]:   Accuracy Decimals: 2
[18:01:12][C][mqtt_subscribe.sensor:032]:   Topic: SolaxPowerControl/P_Wirk_L1
[18:01:12][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=12954 (now=13986)
[18:01:12][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:12][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:12][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:12][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:12][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:12][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:12][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:12][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:12][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:12][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:12][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:12][V][component:205]: Components should block for at most 20-30ms.
[18:01:12][C][mqtt.sensor:027]: MQTT Sensor 'solax-meter-gateway power demand':
[18:01:12][C][mqtt.sensor:031]:   State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state'
[18:01:12][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:12][C][mqtt.text_sensor:023]: MQTT Text Sensor 'solax-meter-gateway operation mode':
[18:01:12][C][mqtt.text_sensor:024]:   State Topic: 'solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state'
[18:01:12][C][mqtt.switch:041]: MQTT Switch 'solax-meter-gateway emergency power off': 
[18:01:12][C][mqtt.switch:042]:   State Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/state'
[18:01:12][C][mqtt.switch:042]:   Command Topic: 'solax-meter-gateway/switch/solax-meter-gateway_emergency_power_off/command'
[18:01:12][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:12][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:12][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:12][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:12][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:13][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:13][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:13][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:13][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:13][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:13][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:13][V][component:205]: Components should block for at most 20-30ms.
[18:01:13][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:13][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:13][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:13][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:13][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:13][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:13][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:13][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:13][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:13][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:13][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:13][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:13][V][component:205]: Components should block for at most 20-30ms.
[18:01:13][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=14527 (now=14635)
[18:01:13][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:13][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[18:01:13][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[18:01:13][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:13][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[18:01:13][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
[18:01:13][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=13954 (now=14962)
[18:01:13][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[18:01:13][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[18:01:13][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:13][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[18:01:13][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
[18:01:14][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[18:01:14][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[18:01:14][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:14][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[18:01:14][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
[18:01:14][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:14][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:14][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:14][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:14][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:14][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:14][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:14][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:14][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:14][V][component:205]: Components should block for at most 20-30ms.
[18:01:14][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:14][VV][scheduler:032]: set_timeout(name='', timeout=0)
[18:01:14][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=15824 (now=15828)
[18:01:14][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:14][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:14][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:14][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:14][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:14][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:14][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:14][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:14][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:14][V][component:205]: Components should block for at most 20-30ms.
[18:01:14][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=14954 (now=15971)
[18:01:14][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:14][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:14][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:14][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:14][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:14][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:14][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:14][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:14][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:14][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:14][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:14][V][component:205]: Components should block for at most 20-30ms.
[18:01:14][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:15][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:15][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:15][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:15][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:15][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:15][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:15][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:15][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:15][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:15][V][component:205]: Components should block for at most 20-30ms.
[18:01:15][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:15][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:15][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:15][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:15][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:15][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:15][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:15][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:15][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:15][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:15][V][component:205]: Components should block for at most 20-30ms.
[18:01:15][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:15][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:15][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:15][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:15][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:15][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:15][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:15][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:15][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:15][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:15][V][component:205]: Components should block for at most 20-30ms.
[18:01:15][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=15954 (now=17054)
[18:01:15][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:15][VV][scheduler:032]: set_timeout(name='', timeout=0)
[18:01:15][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=17084 (now=17105)
[18:01:15][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:15][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:15][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:15][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:15][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:15][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:15][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:15][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:15][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:16][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:16][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:16][V][component:205]: Components should block for at most 20-30ms.
[18:01:16][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:16][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:16][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:16][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:16][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:16][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:16][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:16][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:16][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:16][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:16][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:16][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:16][V][component:205]: Components should block for at most 20-30ms.
[18:01:16][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:16][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:16][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:16][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:16][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:16][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:16][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:16][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:16][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:16][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:16][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:16][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:16][V][component:205]: Components should block for at most 20-30ms.
[18:01:16][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:16][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=16954 (now=17954)
[18:01:16][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:16][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:16][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:16][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:16][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:16][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:16][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:16][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:16][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:16][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:16][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:16][V][component:205]: Components should block for at most 20-30ms.
[18:01:16][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:16][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:17][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:17][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:17][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:17][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:17][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:17][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:17][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:17][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:17][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:17][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:17][V][component:205]: Components should block for at most 20-30ms.
[18:01:17][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=18374 (now=18405)
[18:01:17][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:17][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:17][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:17][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:17][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:17][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:17][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:17][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:17][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:17][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:17][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:17][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:17][V][component:205]: Components should block for at most 20-30ms.
[18:01:17][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:17][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:17][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:17][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:17][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:17][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:17][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:17][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:17][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:17][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:17][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:17][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:17][V][component:205]: Components should block for at most 20-30ms.
[18:01:17][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:17][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=17954 (now=18976)
[18:01:17][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:17][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:17][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:17][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:17][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:17][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:17][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:17][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:17][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:17][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:17][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:17][V][component:205]: Components should block for at most 20-30ms.
[18:01:17][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:18][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:18][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:18][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:18][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:18][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:18][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:18][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:18][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:18][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:18][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:18][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:18][V][component:205]: Components should block for at most 20-30ms.
[18:01:18][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:18][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:18][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:18][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:18][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:18][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:18][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:18][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:18][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:18][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:18][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:18][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:18][V][component:205]: Components should block for at most 20-30ms.
[18:01:18][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=19728 (now=19745)
[18:01:18][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:18][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:18][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:18][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:18][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:18][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:18][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:18][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:18][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:18][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:18][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:18][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:18][V][component:205]: Components should block for at most 20-30ms.
[18:01:18][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=18954 (now=20012)
[18:01:18][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:18][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:18][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:18][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:18][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:18][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:18][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:18][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:18][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:18][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:18][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:18][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:18][V][component:205]: Components should block for at most 20-30ms.
[18:01:19][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:19][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:19][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:19][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:19][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:19][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:19][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:19][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:19][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:19][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:19][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:19][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:19][V][component:205]: Components should block for at most 20-30ms.
[18:01:19][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:19][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:19][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:19][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:19][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:19][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:19][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:19][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:19][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:19][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:19][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:19][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:19][V][component:205]: Components should block for at most 20-30ms.
[18:01:19][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:19][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=19954 (now=20954)
[18:01:19][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:19][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:19][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:19][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:19][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:19][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:19][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:19][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:19][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:19][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:19][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:19][V][component:205]: Components should block for at most 20-30ms.
[18:01:19][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=20985 (now=21090)
[18:01:19][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:19][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:19][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:19][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:19][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:19][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:20][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:20][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:20][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:20][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:20][V][component:205]: Components should block for at most 20-30ms.
[18:01:20][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:20][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:20][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:20][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:20][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:20][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:20][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:20][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:20][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:20][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.10 s).
[18:01:20][V][component:205]: Components should block for at most 20-30ms.
[18:01:20][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:20][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:20][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:20][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:20][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:20][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:20][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:20][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:20][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:20][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:20][V][component:205]: Components should block for at most 20-30ms.
[18:01:20][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:20][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=20954 (now=21955)
[18:01:20][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:20][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:20][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:20][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:20][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:20][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:20][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:20][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:20][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:20][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:20][V][component:205]: Components should block for at most 20-30ms.
[18:01:20][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:20][VV][scheduler:032]: set_timeout(name='', timeout=0)
[18:01:21][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=22289 (now=22293)
[18:01:21][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:21][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:21][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:21][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:21][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:21][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:21][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:21][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:21][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:21][V][component:205]: Components should block for at most 20-30ms.
[18:01:21][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:21][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:21][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:21][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:21][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:21][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:21][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:21][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:21][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:21][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:21][V][component:205]: Components should block for at most 20-30ms.
[18:01:21][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:21][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:21][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:21][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:21][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:21][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:21][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:21][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:21][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:21][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:21][V][component:205]: Components should block for at most 20-30ms.
[18:01:21][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=21954 (now=22973)
[18:01:21][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:21][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:21][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:21][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:21][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:21][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:21][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:21][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:21][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:21][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:21][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:21][V][component:205]: Components should block for at most 20-30ms.
[18:01:21][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:22][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:22][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:22][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:22][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:22][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:22][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:22][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:22][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:22][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:22][V][component:205]: Components should block for at most 20-30ms.
[18:01:22][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:22][VV][scheduler:032]: set_timeout(name='', timeout=0)
[18:01:22][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=23614 (now=23618)
[18:01:22][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:22][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:22][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:22][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:22][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:22][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:22][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:22][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:22][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:22][V][component:205]: Components should block for at most 20-30ms.
[18:01:22][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:22][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:22][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:22][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:22][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:22][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:22][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:22][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:22][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:22][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:22][V][component:205]: Components should block for at most 20-30ms.
[18:01:22][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=22954 (now=24041)
[18:01:22][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:22][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:22][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:22][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:22][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:22][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:22][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:22][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:22][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:22][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:23][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:23][V][component:205]: Components should block for at most 20-30ms.
[18:01:23][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:23][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:23][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:23][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:23][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:23][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:23][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:23][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:23][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:23][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:23][V][component:205]: Components should block for at most 20-30ms.
[18:01:23][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:23][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:23][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:23][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:23][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:23][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:23][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:23][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:23][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:23][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:23][V][component:205]: Components should block for at most 20-30ms.
[18:01:23][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:23][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=23954 (now=24960)
[18:01:23][VV][scheduler:032]: set_timeout(name='', timeout=0)
[18:01:23][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=24973 (now=24977)
[18:01:23][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:23][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:23][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:23][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:23][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:23][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:23][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:23][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:23][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:23][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:23][V][component:205]: Components should block for at most 20-30ms.
[18:01:23][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:23][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:23][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:24][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:24][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:24][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:24][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:24][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:24][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:24][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:24][V][component:205]: Components should block for at most 20-30ms.
[18:01:24][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:24][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:24][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:24][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:24][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:24][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:24][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:24][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:24][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:24][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:24][V][component:205]: Components should block for at most 20-30ms.
[18:01:24][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:24][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:24][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:24][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:24][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:24][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:24][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:24][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:24][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:24][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:24][V][component:205]: Components should block for at most 20-30ms.
[18:01:24][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:24][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=24954 (now=25972)
[18:01:24][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:24][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:24][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:24][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:24][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:24][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:24][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:24][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:24][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:24][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:24][V][component:205]: Components should block for at most 20-30ms.
[18:01:24][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:24][VV][scheduler:032]: set_timeout(name='', timeout=0)
[18:01:24][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=26268 (now=26272)
[18:01:25][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:25][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:25][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:25][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:25][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:25][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:25][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:25][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:25][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:25][V][component:205]: Components should block for at most 20-30ms.
[18:01:25][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:25][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:25][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:25][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:25][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:25][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:25][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:25][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:25][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:25][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:25][V][component:205]: Components should block for at most 20-30ms.
[18:01:25][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:25][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:25][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:25][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:25][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:25][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:25][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:25][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:25][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:25][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:25][V][component:205]: Components should block for at most 20-30ms.
[18:01:25][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=25954 (now=26999)
[18:01:25][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:25][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:25][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:25][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:25][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:25][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:25][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:25][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:25][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:25][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:25][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:25][V][component:205]: Components should block for at most 20-30ms.
[18:01:26][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:26][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:26][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:26][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:26][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:26][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:26][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:26][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:26][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:26][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:26][V][component:205]: Components should block for at most 20-30ms.
[18:01:26][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:26][VV][scheduler:032]: set_timeout(name='', timeout=0)
[18:01:26][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=27571 (now=27592)
[18:01:26][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:26][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:26][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:26][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:26][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:26][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:26][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:26][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:26][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:26][V][component:205]: Components should block for at most 20-30ms.
[18:01:26][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:26][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=26954 (now=27957)
[18:01:26][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:26][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:26][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:26][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:26][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:26][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:26][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:26][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:26][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:26][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:26][V][component:205]: Components should block for at most 20-30ms.
[18:01:26][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:26][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:26][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:26][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:26][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:26][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:27][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:27][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:27][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:27][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:27][V][component:205]: Components should block for at most 20-30ms.
[18:01:27][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:27][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:27][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:27][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:27][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:27][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:27][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:27][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:27][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:27][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:27][V][component:205]: Components should block for at most 20-30ms.
[18:01:27][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:27][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[18:01:27][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[18:01:27][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:27][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.01.9B.F8.7F (7)
[18:01:27][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 411.989990
[18:01:27][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 411.98999 W with 0 decimals of accuracy
[18:01:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='412' retain=1)
[18:01:27][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[18:01:27][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[18:01:27][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[18:01:27][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[18:01:27][V][component:205]: Components should block for at most 20-30ms.
[18:01:27][VV][scheduler:225]: Running timeout '' with interval=0 last_execution=28877 (now=28900)
[18:01:27][D][uart_debug:114]: >>> 01:03:02:01:9B:F8:7F
[18:01:27][VV][scheduler:225]: Running interval 'update' with interval=1000 last_execution=27954 (now=28961)
[18:01:27][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)
[18:01:27][D][uart_debug:114]: <<< 01:03:00:08:00:04:C5:CB
[18:01:27][VV][uart.arduino_esp8266:180]:     Flushing...
[18:01:27][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.08.00.00.00.00.00.00.00.00 (11)
[18:01:27][D][uart_debug:114]: >>> 01:03:08:00:00:00:00:00:00:00:00:95:D7
syssi commented 1 year ago

Ich hatte noch keine Möglichkeit das Log im Detail anzusehen aber schonmal zum besseren Verständnis: Das Gateway soll die Werte von SDM 1:1 weiterreichen. Hier findet keine Manipulation statt bis auf das Runden auf keine Nachkommastellen.

Meldet der SDM / das Smartmeter also einen Bezug von 500W aus dem Netz, dann fordert es den Solax auf diese 500W zu erzeugen. Daraufhin singt der Bezug des SDM auf 0 Watt. Nun muss der Solax diese 500W halten. Sieht der Solax im weiteren Verlauf -50W auf der Uhr, müsste er die 500 auf 450W reduzieren. Das Gateway selbst greift hier nicht ein.

dirk99 commented 1 year ago

ich habe es noch einmal heute verifiziert. Scheinbar liest der ESPhome nur einmal den MQTT Wert und gibt diesen dann immer wieder an den Solax Inverter weiter. Ich sehe auch, wie dieser in der Solax Cloud nach dem nächsten Update ankommt. Kannst Du bitte mal das Logging erweitern und jedes mal den MQTT Wert ausgeben. Im ioBroker kann ich sehen. das dieser Wert sich sekündlich ändert. Wenn ich den ESPhome neu starte, kommt einmalig ein neuer Wert. Mit dem Thema dass der Inverten dann auf 0W Produktion geht, werde ich mich an den Solaxsupport wenden, wenn es soweit läuft. Danke schonmal vorab für Deinen SUPER SUPPORT...

syssi commented 1 year ago

Ich habe folgendes Log-Level gesetzt:

logger:
  level: VERY_VERBOSE
  logs:
    scheduler: DEBUG

Und die esp8266-meter-gateway.yaml daraufhin auf einen ESP8266 geflasht. Daraufhin bucht sich der ESP auf dem MQTT-Broker ein und meldet folgendes:

[12:57:50][VV][solax_meter_gateway:089]: New power demand received (-406.53). Resetting inactivity timeout (35626)
[12:57:51][V][sensor:043]: 'solax-meter-gateway instantaneous power consumption': Received new state -408.170013
[12:57:51][D][sensor:093]: 'solax-meter-gateway instantaneous power consumption': Sending state -408.17001 W with 2 decimals of accuracy
[12:57:51][VV][solax_meter_gateway:089]: New power demand received (-408.17). Resetting inactivity timeout (36630)
[12:57:52][V][sensor:043]: 'solax-meter-gateway instantaneous power consumption': Received new state -410.359985
[12:57:52][D][sensor:093]: 'solax-meter-gateway instantaneous power consumption': Sending state -410.35999 W with 2 decimals of accuracy
[12:57:52][VV][solax_meter_gateway:089]: New power demand received (-410.36). Resetting inactivity timeout (37626)
[12:57:53][V][sensor:043]: 'solax-meter-gateway instantaneous power consumption': Received new state -409.049988
[12:57:53][D][sensor:093]: 'solax-meter-gateway instantaneous power consumption': Sending state -409.04999 W with 2 decimals of accuracy
[12:57:53][VV][solax_meter_gateway:089]: New power demand received (-409.05). Resetting inactivity timeout (38633)
[12:57:54][V][sensor:043]: 'solax-meter-gateway instantaneous power consumption': Received new state -407.410004
[12:57:54][D][sensor:093]: 'solax-meter-gateway instantaneous power consumption': Sending state -407.41000 W with 2 decimals of accuracy
[12:57:54][VV][solax_meter_gateway:089]: New power demand received (-407.41). Resetting inactivity timeout (39643)
[12:57:55][V][sensor:043]: 'solax-meter-gateway instantaneous power consumption': Received new state -409.750000
[12:57:55][D][sensor:093]: 'solax-meter-gateway instantaneous power consumption': Sending state -409.75000 W with 2 decimals of accuracy
[12:57:55][VV][solax_meter_gateway:089]: New power demand received (-409.75). Resetting inactivity timeout (40629)
[12:57:56][V][sensor:043]: 'solax-meter-gateway instantaneous power consumption': Received new state -411.790009
[12:57:56][D][sensor:093]: 'solax-meter-gateway instantaneous power consumption': Sending state -411.79001 W with 2 decimals of accuracy

Diese Meldungen wuerde ich auch gerne in deinem Logbuch sehen. Insbesondere die Zeile

[12:57:55][VV][solax_meter_gateway:089]: New power demand received (-409.75). Resetting inactivity timeout (40629)

Als naechstes habe ich einen Solax-Inverter imitiert mit der folgenden Konfiguration:

tests/esp8266-query-sdm230.yaml

Diese habe ich auf einen zweiten ESP geflasht und die beiden ESPs mit gekreuzten Datenleitungen verbunden. Im Logbuch sollte man nun auch die Anfragen des Fake-Solax sehen und die Komponente antwortet:

[13:05:10][V][sensor:043]: 'solax-meter-gateway instantaneous power consumption': Received new state 832.460022
[13:05:10][D][sensor:093]: 'solax-meter-gateway instantaneous power consumption': Sending state 832.46002 W with 2 decimals of accuracy
[13:05:10][VV][solax_meter_gateway:089]: New power demand received (832.46). Resetting inactivity timeout (475639)
[13:05:10][VV][solax_meter_modbus:069]: RX <- 01.03.00.0B.00.01.F5.C8 (8)
[13:05:10][D][uart_debug:114]: <<< 01:03:00:0B:00:01:F5:C8
[13:05:10][VV][uart.arduino_esp8266:180]:     Flushing...
[13:05:10][V][solax_meter_modbus:181]: SolaxMeterModbus write raw: 01.03.02.00.00 (5)
[13:05:10][D][uart_debug:114]: >>> 01:03:02:00:00:B8:44
[13:05:11][V][sensor:043]: 'solax-meter-gateway instantaneous power consumption': Received new state 829.619995
[13:05:11][D][sensor:093]: 'solax-meter-gateway instantaneous power consumption': Sending state 829.62000 W with 2 decimals of accuracy
[13:05:11][VV][solax_meter_gateway:089]: New power demand received (829.62). Resetting inactivity timeout (476642)
[13:05:11][VV][solax_meter_modbus:069]: RX <- 01.03.00.0E.00.01.E5.C9 (8)
[13:05:11][D][uart_debug:114]: <<< 01:03:00:0E:00:01:E5:C9
[13:05:11][VV][uart.arduino_esp8266:180]:     Flushing...
[13:05:11][V][solax_meter_modbus:127]: SolaxMeterModbus write: 01.03.02.03.3D.79.65 (7)
[13:05:11][V][sensor:043]: 'solax-meter-gateway power demand': Received new state 829.619995
[13:05:11][D][sensor:093]: 'solax-meter-gateway power demand': Sending state 829.62000 W with 0 decimals of accuracy
[13:05:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_power_demand/state' payload='830' retain=1)
[13:05:11][V][text_sensor:013]: 'solax-meter-gateway operation mode': Received new state On
[13:05:11][D][text_sensor:064]: 'solax-meter-gateway operation mode': Sending state 'On'
[13:05:11][V][mqtt:422]: Publish(topic='solax-meter-gateway/sensor/solax-meter-gateway_operation_mode/state' payload='On' retain=1)
[13:05:11][V][component:204]: Component solax_meter_modbus took a long time for an operation (0.09 s).
[13:05:11][V][component:205]: Components should block for at most 20-30ms.
[13:05:11][D][uart_debug:114]: >>> 01:03:02:03:3D:79:65
[13:05:12][V][sensor:043]: 'solax-meter-gateway instantaneous power consumption': Received new state 830.340027
[13:05:12][D][sensor:093]: 'solax-meter-gateway instantaneous power consumption': Sending state 830.34003 W with 2 decimals of accuracy
[13:05:12][VV][solax_meter_gateway:089]: New power demand received (830.34). Resetting inactivity timeout (477645)
[13:05:12][VV][solax_meter_modbus:069]: RX <- 01.03.00.08.00.04.C5.CB (8)

Guckt man ins Logbuch des Fake-Solax findet man hier den reinen UART/RS485-Verkehr:

[13:06:15][D][uart_debug:114]: >>> 01:03:00:0B:00:01:F5:C8    # Solax handshake request
[13:06:15][D][uart_debug:114]: <<< 01:03:02:00:00:B8:44       # Gateway handshake response
[13:06:16][D][uart_debug:114]: >>> 01:03:00:0E:00:01:E5:C9    # Solax power conumption request
[13:06:16][D][uart_debug:114]: <<< 01:03:02:02:FF:F9:64       # Gateway power consumption response
[13:06:17][D][uart_debug:114]: >>> 01:03:00:08:00:04:C5:CB    # Solax total energy request
[13:06:17][D][uart_debug:114]: <<< 01:03:08:00:00:00:00:00:00:00:00:95:D7   # Gateway dummy response
[13:06:20][D][uart_debug:114]: >>> 01:03:00:0B:00:01:F5:C8
[13:06:20][D][uart_debug:114]: <<< 01:03:02:00:00:B8:44
[13:06:21][D][uart_debug:114]: >>> 01:03:00:0E:00:01:E5:C9
[13:06:21][D][uart_debug:114]: <<< 01:03:02:03:3B:F9:67
[13:06:22][D][uart_debug:114]: >>> 01:03:00:08:00:04:C5:CB
[13:06:22][D][uart_debug:114]: <<< 01:03:08:00:00:00:00:00:00:00:00:95:D7
[13:06:25][D][uart_debug:114]: >>> 01:03:00:0B:00:01:F5:C8
[13:06:25][D][uart_debug:114]: <<< 01:03:02:00:00:B8:44
[13:06:26][D][uart_debug:114]: >>> 01:03:00:0E:00:01:E5:C9
[13:06:26][D][uart_debug:114]: <<< 01:03:02:03:51:79:48
[13:06:27][D][uart_debug:114]: >>> 01:03:00:08:00:04:C5:CB
[13:06:27][D][uart_debug:114]: <<< 01:03:08:00:00:00:00:00:00:00:00:95:D7

Im Testbett arbeitet die Implementierung, wie sie soll. Wir sollten uns die MQTT-Server-Konfiguration deines ioBrokers einmal genauer ansehen. Ich arbeite mit einer Mosquitto-Instanz als MQTT-Broker, von welcher ich weiss, dass sie sehr gut mit ESPHome harmoniert.

syssi commented 1 year ago

Kannst du deine MQTT-Konfiguration einmal mit dieser hier vergleichen bzw. ein solches Screenshot zur Verfügung stellen? https://github.com/syssi/esphome-jk-bms/issues/295

dirk99 commented 1 year ago

Es läuft, Danke für Dein Super Support. Es war ein Schicht 8 Fehler bei mir im MQTT Adapter. Es lag an Maske zum Bekanntgeben eigener States. Ich hatte mit einem MQTT Client die Werte gepublished. Somit hat ein weiter Client auch feinedie Werte Angezeigt. aber der Broker hat sie nicht gepublished. Jetzt habe ich noch eine Frage. Kann der gleiche ESPhome parallel auch alle Status Werte periodisch vom Solax Inverter abrufen und via MQTT publishen?

syssi commented 1 year ago

Kann der gleiche ESPhome parallel auch alle Status Werte periodisch vom Solax Inverter abrufen und via MQTT publishen?

Leider nein. Das ist aber keine Limitierung des ESPs, sondern eine doofe Limitierung des Solax-Inverters. Im Modbus-Modus ist der Inverter ein Slave auf dem Bus und die ESPHome-Implementierung nimmt die Rolle eine Masters ein und befragt den Solax periodisch nach neuen Messdaten.

Im "Meter Modus" ist der Solax der Master und befragt periodisch das Smartmeter / den SDM oder in unserem Fall das Gateway nach Messwerten. Wir duerfen auf diesem Bus nur antworten, wenn der Master etwas fragt. Selbst wenn wir zusaetzliche Requests fuer Messdaten auf den Bus schicken wuerden, so wuerde der Inverter nicht darauf reagieren.

Moechtest du den Inverter also ueberwachen, dann geht das in deinem Setup nun nicht mehr über den RS485-Anschluss, der ist nun fuer einen anderen Zweck belegt.