Open tanjapetersen opened 6 years ago
Options/ideas:
Data loggers for the fluxgate: NOTE: Current Q330 only has ~24 hours of storage! More storage is needed and a second datalogger as backup.
NOTE: DTU (Danemark, Lars Pederson et al) have a circuit board module that allows to attach a second datalogger to the FGE Fluxgate.
Consider to have spare data logger channels available in case MT group would like to add electrodes to EYR (like GA Australia did as part of the AusLAMP project).
Minor CAPEX case for purchasing Q330 w/ storage (model S+) was approved 22 Feb 2019.
Q330+ installed on the 17/04/2019 Closed GeoNet/tickets/issues/4377
We want to ensure a robust k-index delivery (X & Y fluxgate data needed) to GfZ Potsdam. No "-1" for missing data. Data delivery within 5 days after the 1st and 16th day of each month.
Auroraalert Otago website uses EYR (X fluxgate only??); www updates every 10 minutes
EYR is NZ's main INTERMAGNET observatory!! We want to deliver good quality data with ideally no fluxgate data gaps. The F proton data are needed for data quality indication.
EYR data are used for studies on Geomagnetically Induced Currents (GICs). We don't want any data gaps during geomagnetic storms.
We want EYR to be attractive for potential future stakeholders/partners: e.g. Transpower, MetService. 1-minute fluxgate data delivered in real-time (within about 1-minute after recording).