Closed ThunderClap86 closed 9 months ago
Update on the Qwiic... 1,0x6d wouldn't work. Tried 1,0x6D (capital letter) and it worked.
Also if anyone reads this, I read on another closed previous issue the Qwiic board says it can be powered by 12v. Don't, it stopped working just like their issue. Now powered directly by 5v with a jumper and it's back switching again.
Hmm, I think the casing 1,0x6D or 1,0x6d should both work. So I get the feeling the 5v jumper was the fix. I have updated the documentation with this 5volt option.
But nice you got it working.
Sorry, me again.
Hoping to have some support on how to activate the Sparkfun Qwiic Quad Relay. I have performed
i2cdetect -y 1
and received a return for 6d (quad relay board) and 77 (BME280). I was able to correctly configure the BME sensor within the GUI and it is providing a readout. The qwiic relay board is being seen by the Pi, but the "Scan Relays" function is showing no relays, and using the "New Relay" menu item for manual addition I am using the following settings:I have tried several variations for the address and I have read throug the setup guide quite a few ways.
I also have a DockerPi 4 Channel Relay HAT that I understand is on the unsupported list, but same thing. The relay is seen by the Pi, and I can control the on/off through terminal but the TerrariumPi is not seeing it.