Question: Does the lack of fuse matter? #1

Open dturner opened 6 months ago

dturner commented 6 months ago

I'm in the process of building this board and I noticed that the manufacturer's original board has a fuse next to the 240V input, this new design doesn't. Just interested to know whether it was a conscious decision to not include a fuse on this new board design?

Looking at the specs for the machine, the motor is 120W so at 240V that's a draw of 0.5A. Would it be worth changing the wall plug fuse to something lower, say 3A?

Slightly concerned that if a short were to occur, or the fan motor develop a fault, there could be a significant heat build up / fire risk.

thikone commented 6 months ago

The board that came inside my machine does not have a fuse on it. The fuse is mounted on the panel and can be replaced from outside without disassembly of the unit.

I think there are several different boards that can be found in these machines. So it is totally possible that what I have might not be what you have.