This PR contains optimization for data reading from the OPC-UA server.

ashdam commented 3 months ago

The following error is through image

It's related to this kind of messages it worked in the current master branch

BuildInfo(ProductUri='http://xxxxxxxx.com/xxxxxxx/v3.1.6.0', ManufacturerName='xxxxxx', ProductName='xxxxxxx', SoftwareVersion='3.1.6.0', BuildNumber='3.1.6', BuildDate=datetime.datetime(2024, 7, 8, 9, 1, 2, 607366, tzinfo=datetime.timezone.utc))

Here is the config

{
  "server": {
    "name": "MB107_UDC1",
    "url": "opc.tcp://xxxxxxxxx:59300/xxxxx/UnifiedDataCollector",
    "timeoutInMillis": 5000,
    "scanPeriodInMillis": 5000,
    "disableSubscriptions": true,
    "subCheckPeriodInMillis": 100,
    "showMap": false,
    "security": "Basic128Rsa15",
    "identity": {
      "type": "anonymous"
    },
    "mapping": [
      {
        "deviceNodePattern": "Root\\.Objects\\.Server",
        "deviceNamePattern": "MB107_UDC1_A0000K9J76",
        "attributes": [
          {
            "key": "server_uai",
            "path": "${ns=2;b=sbnFUIh4jWVrbbrxt463og==}"
          },
          {
            "key": "device_uai",
            "path": "${ns=2;b=sbnFUIh4jWVrbbrxt463og==}"
          },
          {
            "key": "site_code",
            "path": "${ns=2;b=zCGYLEQhEXoiQHQBVhcIoA==}"
          },
          {
            "key": "line",
            "path": "${ns=2;b=WrO0W3muBdo+gdCYlWooSQ==}"
          }
        ],
        "timeseries": [
          {
            "key": "/Server/ServerStatus/BuildInfo",
            "path": "${ns=0;i=2260}"
          },
          {
            "key": "/Server/UaiInfo/UaiCode",
            "path": "${ns=2;b=sbnFUIh4jWVrbbrxt463og==}"
          }
        ]
      }
    ]
  },
  "logLevel": "INFO",
  "name": "MB107_UDC1",
  "enableRemoteLogging": false,
  "id": "xxxxxxx"
}
ashdam commented 3 months ago

We found another types:

2024-08-14 15:04:55 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - send_to_storage - 1103 - Object of type datetime is not JSON serializable 2024-08-14 15:04:55 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - send_to_storage - 1103 - Object of type EUInformation is not JSON serializable 2024-08-14 15:04:55 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable

Range corresponds with this sample value: [Range(Low=0.0, High=0.0)] EUInformation we couldnt find a node with this name

ashdam commented 3 months ago

Started the GW with both connectors disabled. This was the output

Cannot load GRPC connector!
2024-08-14 15:42:13 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 168 - Gateway starting...
2024-08-14 15:42:13 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 172 - ThingsBoard IoT gateway version: 3.5.1
2024-08-14 15:42:13 - |INFO| - [tb_loader.py] - tb_loader - import_module - 68 - Import OpcUaConnector from /home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua.
2024-08-14 15:42:13 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 81 - Connector configuration has been updated to the new format.
2024-08-14 15:42:13 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-14 15:42:13 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 81 - Connector configuration has been updated to the new format.
2024-08-14 15:42:13 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-14 15:42:13 - |WARNING| - [tb_updater.py] - tb_updater - check_for_new_version - 92 - Cannot connect to the update service. PLease check your internet connection.
2024-08-14 15:42:14 - |INFO| - [tb_loader.py] - tb_loader - import_module - 68 - Import OpcUaUplinkConverter from /home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua.
2024-08-14 15:42:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000K9K77
2024-08-14 15:42:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC1_A0000K9J76
2024-08-14 15:42:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBL98
2024-08-14 15:42:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB38Q
2024-08-14 15:42:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB58S
2024-08-14 15:42:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB48R
2024-08-14 15:42:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA97W
2024-08-14 15:42:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBH94
2024-08-14 15:42:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAD80
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA77U
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAB7Y
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB88V
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBK97
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAC7Z
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBG93
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA87V
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000K9L78
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA67T
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAA7X
2024-08-14 15:42:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBJ96
2024-08-14 15:42:16 - |INFO| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 70 - Non primitive data type: <class 'datetime.datetime'>
2024-08-14 15:42:16 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Error in main loop: 'datetime.datetime' object has no attribute 'Value'
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 229, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 505, in __poll_nodes
    device.converter.convert(device.nodes, device_values)
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_uplink_converter.py", line 71, in convert
    data = val.Value.Value
           ^^^^^^^^^
AttributeError: 'datetime.datetime' object has no attribute 'Value'
2024-08-14 15:42:18 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-14 15:42:18 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-14 15:42:18 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-14 15:42:24 - |INFO| - [tb_device_mqtt.py] - tb_device_mqtt - _on_connect - 352 - MQTT client <paho.mqtt.client.Client object at 0x7d80fe8ce660> - Connected!
2024-08-14 15:42:24 - |INFO| - [tb_gateway_mqtt.py] - tb_gateway_mqtt - gw_subscribe_to_attribute - 236 - Subscribed to *|* with id 1 for device *
2024-08-14 15:42:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - 'TBGatewayService' object has no attribute '_TBGatewayService__check_devices_idle'
2024-08-14 15:42:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - 'TBGatewayService' object has no attribute '_TBGatewayService__check_devices_idle'
2024-08-14 15:42:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - 'TBGatewayService' object has no attribute '_TBGatewayService__check_devices_idle'
2024-08-14 15:42:24 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 235 - Gateway started.
2024-08-14 15:42:24 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - __init__ - 68 - Remote Configurator started
2024-08-14 15:42:24 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 247 - Initials connections with connectors was failed, trying again...
2024-08-14 15:42:25 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-14 15:42:25 - |INFO| - [opcua_connector.py] - opcua_connector - close - 118 - Stopping OPC-UA Connector
2024-08-14 15:42:25 - |INFO| - [opcua_connector.py] - opcua_connector - __disconnect - 141 - MB107_UDC1 has been disconnected from OPC-UA Server.
2024-08-14 15:42:26 - |INFO| - [opcua_connector.py] - opcua_connector - close - 131 - MB107_UDC1 has been stopped.
2024-08-14 15:42:26 - |INFO| - [opcua_connector.py] - opcua_connector - close - 118 - Stopping OPC-UA Connector
2024-08-14 15:42:26 - |INFO| - [opcua_connector.py] - opcua_connector - close - 131 - MB107_UDC2 has been stopped.
2024-08-14 15:42:26 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.

Enabled both connectors and here is the output:

2024-08-14 15:42:26 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-14 15:45:39 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-14 15:45:39 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-14 15:45:39 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-14 15:45:40 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-14 15:45:40 - |INFO| - [opcua_connector.py] - opcua_connector - close - 118 - Stopping OPC-UA Connector
2024-08-14 15:45:40 - |INFO| - [opcua_connector.py] - opcua_connector - __disconnect - 141 - MB107_UDC1 has been disconnected from OPC-UA Server.
2024-08-14 15:45:41 - |INFO| - [opcua_connector.py] - opcua_connector - close - 131 - MB107_UDC1 has been stopped.
2024-08-14 15:45:41 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-14 15:45:41 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-14 15:45:41 - |ERROR| - [opcua_connector.py] - opcua_connector - start_client - 247 - Error in main loop, trying to reconnect: %s
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 229, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 498, in __poll_nodes
    values = await self.__client.read_values([node_config['var'] for device in self.__device_nodes for node_config in device.nodes])
             ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/client.py", line 921, in read_values
    res = await self.read_attributes(nodes, attr=ua.AttributeIds.Value)
          ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/client.py", line 915, in read_attributes
    return await self.uaclient.read_attributes(nodeids, attr)
           ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/ua_client.py", line 760, in read_attributes
    data = await self.protocol.send_request(request)
           ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/ua_client.py", line 172, in send_request
    self.check_answer(data, f" in response to {request.__class__.__name__}")
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/ua_client.py", line 181, in check_answer
    hdr.ServiceResult.check()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/ua/uatypes.py", line 377, in check
    raise UaStatusCodeError(self.value)
asyncua.ua.uaerrors._auto.BadNothingToDo: No processing could be done because there was nothing to do.(BadNothingToDo)
2024-08-14 15:45:41 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-14 15:45:42 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __connect_with_connectors - 919 - ['55837108-a714-4b04-955a-41b34c4e9775'] Connector with name MB107_UDC1 already exists and not stopped!
2024-08-14 15:45:42 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 81 - Connector configuration has been updated to the new format.
2024-08-14 15:45:42 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-14 15:45:42 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-14 15:45:42 - |INFO| - [opcua_connector.py] - opcua_connector - close - 118 - Stopping OPC-UA Connector
2024-08-14 15:45:42 - |INFO| - [opcua_connector.py] - opcua_connector - __disconnect - 141 - MB107_UDC1 has been disconnected from OPC-UA Server.
2024-08-14 15:45:42 - |INFO| - [opcua_connector.py] - opcua_connector - close - 131 - MB107_UDC1 has been stopped.
2024-08-14 15:45:42 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-14 15:45:42 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __connect_with_connectors - 919 - ['b8a19e99-5664-4988-8e72-11c3c0eb27e5'] Connector with name MB107_UDC2 already exists and not stopped!
2024-08-14 15:45:42 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-14 15:45:42 - |INFO| - [opcua_connector.py] - opcua_connector - close - 118 - Stopping OPC-UA Connector
2024-08-14 15:45:42 - |ERROR| - [opcua_connector.py] - opcua_connector - start_client - 247 - Error in main loop, trying to reconnect: %s
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 229, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 498, in __poll_nodes
    values = await self.__client.read_values([node_config['var'] for device in self.__device_nodes for node_config in device.nodes])
             ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/client.py", line 921, in read_values
    res = await self.read_attributes(nodes, attr=ua.AttributeIds.Value)
          ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/client.py", line 915, in read_attributes
    return await self.uaclient.read_attributes(nodeids, attr)
           ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/ua_client.py", line 760, in read_attributes
    data = await self.protocol.send_request(request)
           ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/ua_client.py", line 172, in send_request
    self.check_answer(data, f" in response to {request.__class__.__name__}")
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/ua_client.py", line 181, in check_answer
    hdr.ServiceResult.check()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/ua/uatypes.py", line 377, in check
    raise UaStatusCodeError(self.value)
asyncua.ua.uaerrors._auto.BadNothingToDo: No processing could be done because there was nothing to do.(BadNothingToDo)
2024-08-14 15:45:43 - |INFO| - [opcua_connector.py] - opcua_connector - close - 131 - MB107_UDC2 has been stopped.
2024-08-14 15:45:43 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __connect_with_connectors - 919 - ['55837108-a714-4b04-955a-41b34c4e9775'] Connector with name MB107_UDC1 already exists and not stopped!
2024-08-14 15:45:43 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 81 - Connector configuration has been updated to the new format.
2024-08-14 15:45:43 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-14 15:45:43 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000K9K77
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBL98
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB38Q
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB58S
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB48R
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA97W
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBH94
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAD80
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA77U
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAB7Y
2024-08-14 15:45:44 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB88V
2024-08-14 15:45:45 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBK97
2024-08-14 15:45:45 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAC7Z
2024-08-14 15:45:45 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBG93
2024-08-14 15:45:45 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA87V
2024-08-14 15:45:45 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000K9L78
2024-08-14 15:45:45 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA67T
2024-08-14 15:45:45 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAA7X
2024-08-14 15:45:45 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBJ96
2024-08-14 15:45:46 - |INFO| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 70 - Non primitive data type: <class 'datetime.datetime'>
2024-08-14 15:45:46 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Error in main loop: 'datetime.datetime' object has no attribute 'Value'
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 229, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 505, in __poll_nodes
    device.converter.convert(device.nodes, device_values)
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_uplink_converter.py", line 71, in convert
    data = val.Value.Value
           ^^^^^^^^^
AttributeError: 'datetime.datetime' object has no attribute 'Value'

We also detected in TB that configuration was lost in the first connector "MB107_UDC1" but not in the second one

image

ashdam commented 3 months ago

Steps followed and their outputs

1) I updated configuration from MB107_UDC1 to it's correct status from last time it was "deleted"/missing 2) After activating MB107_UDC1 y got this error from "/Server/ServerStatus/BuildInfo" key (variable) image

3) Stopped MB107_UDC1 2024-08-15 07:39:36 - |INFO| - [opcua_connector.py] - opcua_connector - close - 131 - MB107_UDC1 has been stopped.

4) Started MB107_UDC2, the one with almost 4k keys and 20 devices image

Full log


(venv) admin@CAC-POCDATA-udc1:~/tb-iot-gateway-latest/thingsboard-gateway$ python3 ./thingsboard_gateway/tb_gateway.py
Cannot load GRPC connector!
2024-08-15 07:35:23 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 168 - Gateway starting...
2024-08-15 07:35:23 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 172 - ThingsBoard IoT gateway version: 3.5.1
2024-08-15 07:35:23 - |WARNING| - [tb_updater.py] - tb_updater - check_for_new_version - 92 - Cannot connect to the update service. PLease check your internet connection.
2024-08-15 07:35:23 - |INFO| - [tb_loader.py] - tb_loader - import_module - 68 - Import OpcUaConnector from /home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua.
2024-08-15 07:35:23 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 81 - Connector configuration has been updated to the new format.
2024-08-15 07:35:23 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-15 07:35:24 - |INFO| - [tb_loader.py] - tb_loader - import_module - 68 - Import OpcUaUplinkConverter from /home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua.
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000K9K77
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBL98
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB38Q
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB58S
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB48R
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA97W
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBH94
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAD80
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA77U
2024-08-15 07:35:24 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAB7Y
2024-08-15 07:35:25 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB88V
2024-08-15 07:35:25 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBK97
2024-08-15 07:35:25 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAC7Z
2024-08-15 07:35:25 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBG93
2024-08-15 07:35:25 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA87V
2024-08-15 07:35:25 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000K9L78
2024-08-15 07:35:25 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA67T
2024-08-15 07:35:25 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAA7X
2024-08-15 07:35:25 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBJ96
2024-08-15 07:35:26 - |INFO| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 70 - Non primitive data type: <class 'datetime.datetime'>
2024-08-15 07:35:26 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Error in main loop: 'datetime.datetime' object has no attribute 'VariantType'
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 229, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 505, in __poll_nodes
    device.converter.convert(device.nodes, device_values)
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_uplink_converter.py", line 73, in convert
    elif val.VariantType == VariantType.ExtensionObject:
         ^^^^^^^^^^^^^^^
AttributeError: 'datetime.datetime' object has no attribute 'VariantType'
2024-08-15 07:35:28 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-15 07:35:28 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-15 07:35:34 - |INFO| - [tb_device_mqtt.py] - tb_device_mqtt - _on_connect - 352 - MQTT client <paho.mqtt.client.Client object at 0x7132a3c33c80> - Connected!
2024-08-15 07:35:34 - |INFO| - [tb_gateway_mqtt.py] - tb_gateway_mqtt - gw_subscribe_to_attribute - 236 - Subscribed to *|* with id 1 for device *
2024-08-15 07:35:34 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 235 - Gateway started.
2024-08-15 07:35:34 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - __init__ - 68 - Remote Configurator started
2024-08-15 07:35:34 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 247 - Initials connections with connectors was failed, trying again...
2024-08-15 07:35:34 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __load_persistent_devices - 1612 - Connector with id 55837108-a714-4b04-955a-41b34c4e9775 not found, trying to use connector by name!
2024-08-15 07:35:34 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __load_persistent_devices - 1620 - Connector with name MB107_UDC1 not found! probably it is disabled, device MB107_UDC1_A0000K9J76 will be removed from the saved devices
2024-08-15 07:35:35 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:35:35 - |INFO| - [opcua_connector.py] - opcua_connector - close - 118 - Stopping OPC-UA Connector
2024-08-15 07:35:35 - |INFO| - [opcua_connector.py] - opcua_connector - close - 131 - MB107_UDC2 has been stopped.
2024-08-15 07:35:35 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:36:03 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:36:03 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:36:03 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 81 - Connector configuration has been updated to the new format.
2024-08-15 07:36:03 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-15 07:36:03 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:36:03 - |INFO| - [opcua_connector.py] - opcua_connector - close - 118 - Stopping OPC-UA Connector
2024-08-15 07:36:03 - |INFO| - [opcua_connector.py] - opcua_connector - __disconnect - 141 - MB107_UDC1 has been disconnected from OPC-UA Server.
2024-08-15 07:36:05 - |INFO| - [opcua_connector.py] - opcua_connector - close - 131 - MB107_UDC1 has been stopped.
2024-08-15 07:36:05 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 81 - Connector configuration has been updated to the new format.
2024-08-15 07:36:05 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-15 07:36:05 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC1_A0000K9J76
2024-08-15 07:36:05 - |INFO| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 70 - Non primitive data type: <class 'asyncua.ua.uaprotocol_auto.BuildInfo'>
2024-08-15 07:36:05 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Error in main loop: 'BuildInfo' object has no attribute 'VariantType'
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 229, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 505, in __poll_nodes
    device.converter.convert(device.nodes, device_values)
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_uplink_converter.py", line 73, in convert
    elif val.VariantType == VariantType.ExtensionObject:
         ^^^^^^^^^^^^^^^
AttributeError: 'BuildInfo' object has no attribute 'VariantType'
2024-08-15 07:39:36 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:39:36 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:39:36 - |INFO| - [opcua_connector.py] - opcua_connector - close - 118 - Stopping OPC-UA Connector
2024-08-15 07:39:36 - |INFO| - [opcua_connector.py] - opcua_connector - close - 131 - MB107_UDC1 has been stopped.
2024-08-15 07:41:10 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:41:10 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:41:13 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 07:41:13 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 81 - Connector configuration has been updated to the new format.
2024-08-15 07:41:13 - |INFO| - [opcua_connector.py] - opcua_connector - open - 110 - Starting OPC-UA Connector (Async IO)
2024-08-15 07:41:13 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000K9K77
2024-08-15 07:41:13 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBL98
2024-08-15 07:41:13 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB38Q
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB58S
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB48R
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA97W
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBH94
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAD80
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA77U
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAB7Y
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KB88V
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBK97
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAC7Z
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBG93
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA87V
2024-08-15 07:41:14 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000K9L78
2024-08-15 07:41:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KA67T
2024-08-15 07:41:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KAA7X
2024-08-15 07:41:15 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 423 - Added device node: MB107_UDC2_A0000KBJ96
2024-08-15 07:41:15 - |INFO| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 70 - Non primitive data type: <class 'datetime.datetime'>
2024-08-15 07:41:15 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Error in main loop: 'datetime.datetime' object has no attribute 'VariantType'
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 229, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 505, in __poll_nodes
    device.converter.convert(device.nodes, device_values)
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_uplink_converter.py", line 73, in convert
    elif val.VariantType == VariantType.ExtensionObject:
         ^^^^^^^^^^^^^^^
AttributeError: 'datetime.datetime' object has no attribute 'VariantType'

Much less errors at least :)

ashdam commented 3 months ago

Steps followed and their outputs:

1) After activating MB107_UDC1 y got this error image

2) Stopped MB107_UDC1 2024-08-15 08:23:33 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received. 2024-08-15 08:23:33 - |INFO| - [opcua_connector.py] - opcua_connector - close - 120 - Stopping OPC-UA Connector 2024-08-15 08:23:33 - |INFO| - [opcua_connector.py] - opcua_connector - close - 133 - MB107_UDC1 has been stopped. 2024-08-15 08:23:33 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.

3) Started MB107_UDC2. Same error image

Full log


(venv) admin@CAC-POCDATA-udc1:~/tb-iot-gateway-latest/thingsboard-gateway$ python3 ./thingsboard_gateway/tb_gateway.py
Cannot load GRPC connector!
2024-08-15 08:21:52 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 168 - Gateway starting...
2024-08-15 08:21:52 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 172 - ThingsBoard IoT gateway version: 3.5.1
2024-08-15 08:21:52 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - _load_connectors - 879 - Connectors - not found!
2024-08-15 08:21:52 - |WARNING| - [tb_updater.py] - tb_updater - check_for_new_version - 92 - Cannot connect to the update service. PLease check your internet connection.
2024-08-15 08:21:57 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-15 08:22:02 - |INFO| - [tb_device_mqtt.py] - tb_device_mqtt - _on_connect - 352 - MQTT client <paho.mqtt.client.Client object at 0x7d61077b5e50> - Connected!
2024-08-15 08:22:02 - |INFO| - [tb_gateway_mqtt.py] - tb_gateway_mqtt - gw_subscribe_to_attribute - 236 - Subscribed to *|* with id 1 for device *
2024-08-15 08:22:03 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 235 - Gateway started.
2024-08-15 08:22:03 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - __init__ - 68 - Remote Configurator started
2024-08-15 08:22:03 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - _load_connectors - 879 - Connectors - not found!
2024-08-15 08:22:03 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 247 - Initials connections with connectors was failed, trying again...
2024-08-15 08:22:03 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __load_persistent_devices - 1612 - Connector with id 55837108-a714-4b04-955a-41b34c4e9775 not found, trying to use connector by name!
2024-08-15 08:22:03 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __load_persistent_devices - 1620 - Connector with name MB107_UDC1 not found! probably it is disabled, device MB107_UDC1_A0000K9J76 will be removed from the saved devices
2024-08-15 08:22:03 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:22:03 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:22:10 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:22:10 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:22:11 - |INFO| - [tb_loader.py] - tb_loader - import_module - 68 - Import OpcUaConnector from /home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua.
2024-08-15 08:22:11 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 83 - Connector configuration has been updated to the new format.
2024-08-15 08:22:11 - |INFO| - [opcua_connector.py] - opcua_connector - open - 112 - Starting OPC-UA Connector (Async IO)
2024-08-15 08:22:11 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:22:11 - |INFO| - [opcua_connector.py] - opcua_connector - close - 120 - Stopping OPC-UA Connector
2024-08-15 08:22:11 - |INFO| - [opcua_connector.py] - opcua_connector - __disconnect - 143 - MB107_UDC1 has been disconnected from OPC-UA Server.
2024-08-15 08:22:12 - |INFO| - [opcua_connector.py] - opcua_connector - close - 133 - MB107_UDC1 has been stopped.
2024-08-15 08:22:12 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 83 - Connector configuration has been updated to the new format.
2024-08-15 08:22:12 - |INFO| - [opcua_connector.py] - opcua_connector - open - 112 - Starting OPC-UA Connector (Async IO)
2024-08-15 08:22:12 - |INFO| - [tb_loader.py] - tb_loader - import_module - 68 - Import OpcUaUplinkConverter from /home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua.
2024-08-15 08:22:12 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC1_A0000K9J76
2024-08-15 08:22:12 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Error in main loop: isinstance() arg 2 must be a type, a tuple of types, or a union
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 231, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 508, in __poll_nodes
    device.converter.convert(device.nodes, device_values)
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_uplink_converter.py", line 65, in convert
    if not isinstance(list, values):
           ^^^^^^^^^^^^^^^^^^^^^^^^
TypeError: isinstance() arg 2 must be a type, a tuple of types, or a union
2024-08-15 08:23:33 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:23:33 - |INFO| - [opcua_connector.py] - opcua_connector - close - 120 - Stopping OPC-UA Connector
2024-08-15 08:23:33 - |INFO| - [opcua_connector.py] - opcua_connector - close - 133 - MB107_UDC1 has been stopped.
2024-08-15 08:23:33 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:24:14 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:24:14 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:24:16 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:24:16 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 83 - Connector configuration has been updated to the new format.
2024-08-15 08:24:16 - |INFO| - [opcua_connector.py] - opcua_connector - open - 112 - Starting OPC-UA Connector (Async IO)
2024-08-15 08:24:17 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000K9K77
2024-08-15 08:24:17 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBL98
2024-08-15 08:24:17 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB38Q
2024-08-15 08:24:17 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB58S
2024-08-15 08:24:17 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB48R
2024-08-15 08:24:17 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA97W
2024-08-15 08:24:17 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBH94
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAD80
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA77U
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAB7Y
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB88V
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBK97
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAC7Z
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBG93
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA87V
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000K9L78
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA67T
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAA7X
2024-08-15 08:24:18 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBJ96
2024-08-15 08:24:19 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Error in main loop: isinstance() arg 2 must be a type, a tuple of types, or a union
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 231, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 508, in __poll_nodes
    device.converter.convert(device.nodes, device_values)
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_uplink_converter.py", line 65, in convert
    if not isinstance(list, values):
           ^^^^^^^^^^^^^^^^^^^^^^^^
TypeError: isinstance() arg 2 must be a type, a tuple of types, or a union
ashdam commented 3 months ago

Starting the gateway image

Full log

Cannot load GRPC connector!
2024-08-15 08:30:53 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 168 - Gateway starting...
2024-08-15 08:30:53 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 172 - ThingsBoard IoT gateway version: 3.5.1
2024-08-15 08:30:54 - |WARNING| - [tb_updater.py] - tb_updater - check_for_new_version - 92 - Cannot connect to the update service. PLease check your internet connection.
2024-08-15 08:30:54 - |INFO| - [tb_loader.py] - tb_loader - import_module - 68 - Import OpcUaConnector from /home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua.
2024-08-15 08:30:54 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 83 - Connector configuration has been updated to the new format.
2024-08-15 08:30:54 - |INFO| - [opcua_connector.py] - opcua_connector - open - 112 - Starting OPC-UA Connector (Async IO)
2024-08-15 08:30:54 - |INFO| - [tb_loader.py] - tb_loader - import_module - 68 - Import OpcUaUplinkConverter from /home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua.
2024-08-15 08:30:54 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000K9K77
2024-08-15 08:30:54 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBL98
2024-08-15 08:30:54 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB38Q
2024-08-15 08:30:54 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB58S
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB48R
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA97W
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBH94
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAD80
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA77U
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAB7Y
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB88V
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBK97
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAC7Z
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBG93
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA87V
2024-08-15 08:30:55 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000K9L78
2024-08-15 08:30:56 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA67T
2024-08-15 08:30:56 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAA7X
2024-08-15 08:30:56 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBJ96
2024-08-15 08:30:56 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Error in main loop: 'DataValue' object has no attribute 'VariantType'
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 231, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 508, in __poll_nodes
    device.converter.convert(device.nodes, device_values)
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_uplink_converter.py", line 99, in convert
    self._log.warning(f"Unsupported data type: {val.VariantType}, will be processed as a string.")
                                                ^^^^^^^^^^^^^^^
AttributeError: 'DataValue' object has no attribute 'VariantType'
2024-08-15 08:30:58 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-15 08:30:59 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-15 08:31:04 - |INFO| - [tb_device_mqtt.py] - tb_device_mqtt - _on_connect - 352 - MQTT client <paho.mqtt.client.Client object at 0x7fc254133ce0> - Connected!
2024-08-15 08:31:04 - |INFO| - [tb_gateway_mqtt.py] - tb_gateway_mqtt - gw_subscribe_to_attribute - 236 - Subscribed to *|* with id 1 for device *
2024-08-15 08:31:05 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 235 - Gateway started.
2024-08-15 08:31:05 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - __init__ - 68 - Remote Configurator started
2024-08-15 08:31:05 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __init__ - 247 - Initials connections with connectors was failed, trying again...
2024-08-15 08:31:05 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __load_persistent_devices - 1612 - Connector with id 55837108-a714-4b04-955a-41b34c4e9775 not found, trying to use connector by name!
2024-08-15 08:31:05 - |WARNING| - [tb_gateway_service.py] - tb_gateway_service - __load_persistent_devices - 1620 - Connector with name MB107_UDC1 not found! probably it is disabled, device MB107_UDC1_A0000K9J76 will be removed from the saved devices
2024-08-15 08:31:05 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:31:05 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:31:06 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:31:06 - |INFO| - [opcua_connector.py] - opcua_connector - close - 120 - Stopping OPC-UA Connector
2024-08-15 08:31:06 - |INFO| - [opcua_connector.py] - opcua_connector - close - 133 - MB107_UDC2 has been stopped.
2024-08-15 08:31:06 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 83 - Connector configuration has been updated to the new format.
2024-08-15 08:31:06 - |INFO| - [opcua_connector.py] - opcua_connector - open - 112 - Starting OPC-UA Connector (Async IO)
2024-08-15 08:31:07 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:31:07 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000K9K77
2024-08-15 08:31:07 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBL98
2024-08-15 08:31:07 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB38Q
2024-08-15 08:31:07 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB58S
2024-08-15 08:31:07 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB48R
2024-08-15 08:31:07 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA97W
2024-08-15 08:31:07 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBH94
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAD80
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA77U
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAB7Y
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB88V
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBK97
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAC7Z
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBG93
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA87V
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000K9L78
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA67T
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAA7X
2024-08-15 08:31:08 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBJ96
2024-08-15 08:31:09 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Error in main loop: 'DataValue' object has no attribute 'VariantType'
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 231, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 508, in __poll_nodes
    device.converter.convert(device.nodes, device_values)
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_uplink_converter.py", line 99, in convert
    self._log.warning(f"Unsupported data type: {val.VariantType}, will be processed as a string.")
                                                ^^^^^^^^^^^^^^^
AttributeError: 'DataValue' object has no attribute 'VariantType'
ashdam commented 3 months ago

Steps followed: 1) Started MB107_UDC1 => No error it seems just warning writing over and over

2024-08-15 08:43:29 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 83 - Connector configuration has been updated to the new format.
2024-08-15 08:43:29 - |INFO| - [opcua_connector.py] - opcua_connector - open - 112 - Starting OPC-UA Connector (Async IO)
2024-08-15 08:43:29 - |INFO| - [tb_loader.py] - tb_loader - import_module - 68 - Import OpcUaUplinkConverter from /home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua.
2024-08-15 08:43:29 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC1_A0000K9J76
2024-08-15 08:43:29 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:29 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:29 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:29 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:29 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:34 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:34 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:34 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:34 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:34 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:39 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:39 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:39 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:39 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:39 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:43:40 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:43:40 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:43:40 - |INFO| - [opcua_connector.py] - opcua_connector - close - 120 - Stopping OPC-UA Connector
2024-08-15 08:43:40 - |INFO| - [opcua_connector.py] - opcua_connector - __disconnect - 143 - MB107_UDC1 has been disconnected from OPC-UA Server.
2024-08-15 08:43:41 - |INFO| - [opcua_connector.py] - opcua_connector - close - 133 - MB107_UDC1 has been stopped.

2) Started MB107_UDC2 and stopped after a few seconds ==> Same no errors but too many warnings in just few seconds hehe

2024-08-15 08:46:58 - |WARNING| - [opcua_connector.py] - opcua_connector - __init__ - 83 - Connector configuration has been updated to the new format.
2024-08-15 08:46:58 - |INFO| - [opcua_connector.py] - opcua_connector - open - 112 - Starting OPC-UA Connector (Async IO)
2024-08-15 08:46:59 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000K9K77
2024-08-15 08:46:59 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBL98
2024-08-15 08:46:59 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB38Q
2024-08-15 08:46:59 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB58S
2024-08-15 08:46:59 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB48R
2024-08-15 08:46:59 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA97W
2024-08-15 08:46:59 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBH94
2024-08-15 08:46:59 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAD80
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA77U
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAB7Y
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KB88V
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBK97
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAC7Z
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBG93
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA87V
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000K9L78
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KA67T
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KAA7X
2024-08-15 08:47:00 - |INFO| - [opcua_connector.py] - opcua_connector - _create_new_devices - 425 - Added device node: MB107_UDC2_A0000KBJ96
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 7, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 11, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 11, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 5, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 1, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 5, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 4, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 11, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 6, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 11, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 4, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 4, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 11, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:01 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
................... many many warnings ............................
2024-08-15 08:47:15 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:15 - |WARNING| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 99 - Unsupported data type: 12, will be processed as a string.
2024-08-15 08:47:16 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:47:16 - |INFO| - [tb_gateway_remote_configurator.py] - tb_gateway_remote_configurator - _process_config_request - 220 - Configuration update request received.
2024-08-15 08:47:16 - |INFO| - [opcua_connector.py] - opcua_connector - close - 120 - Stopping OPC-UA Connector
2024-08-15 08:47:16 - |INFO| - [opcua_connector.py] - opcua_connector - __disconnect - 143 - MB107_UDC2 has been disconnected from OPC-UA Server.
2024-08-15 08:47:17 - |INFO| - [opcua_connector.py] - opcua_connector - close - 133 - MB107_UDC2 has been stopped.
^C2024-08-15 08:47:55 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __stop_gateway - 558 - Stopping...
2024-08-15 08:47:55 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __stop_gateway - 570 - The gateway has been stopped.
2024-08-15 08:47:55 - |INFO| - [tb_gateway_mqtt.py] - tb_gateway_mqtt - gw_unsubscribe - 244 - Unsubscribed from *|*, subscription id '*'
2024-08-15 08:47:55 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _on_disconnect - 343 - MQTT client was disconnected with reason code 0 (The operation completed successfully.)
2024-08-15 08:47:55 - |INFO| - [tb_gateway_service.py] - tb_gateway_service - __read_data_from_storage - 1245 - Send data Thread has been stopped successfully.
ashdam commented 3 months ago

I got many errors but basically these 3:

2024-08-15 09:04:38 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Argument is not JSON serializable
2024-08-15 09:04:38 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 09:04:38 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
samson0v commented 3 months ago

@ashdam do you have logs like: "Unsupported data type: ..., will be processed as a string."? Could you provide them?

ashdam commented 3 months ago

@samson0v no, just those errors over and over on the log

samson0v commented 3 months ago

@ashdam added additional log because we can't understand what object type we got in the converter.

ashdam commented 3 months ago

@samson0v got this error stack from this commit ed0fe1ea

2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:25.098969+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:27.735187+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-15 09:05:50.237477+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)) | and data type: <class 'asyncua.ua.uaprotocol_auto.BuildInfo'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:56.989608+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: ServerStatusDataType(StartTime=datetime.datetime(2024, 8, 12, 6, 22, 56, 989608, tzinfo=datetime.timezone.utc), CurrentTime=datetime.datetime(2024, 8, 15, 9, 5, 50, 237477, tzinfo=datetime.timezone.utc), State=<ServerState.Running: 0>, BuildInfo_=BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)), SecondsTillShutdown=0, ShutdownReason=LocalizedText(Locale=None, Text=None)) | and data type: <class 'asyncua.ua.uaprotocol_auto.ServerStatusDataType'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: StatusCode(value=0) | and data type: <class 'asyncua.ua.uatypes.StatusCode'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-05-26 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2023-08-02 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:56 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-07-10 05:49:20.374000+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:25.098969+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:27.735187+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-15 09:05:51.901776+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)) | and data type: <class 'asyncua.ua.uaprotocol_auto.BuildInfo'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:56.989608+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: ServerStatusDataType(StartTime=datetime.datetime(2024, 8, 12, 6, 22, 56, 989608, tzinfo=datetime.timezone.utc), CurrentTime=datetime.datetime(2024, 8, 15, 9, 5, 51, 901776, tzinfo=datetime.timezone.utc), State=<ServerState.Running: 0>, BuildInfo_=BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)), SecondsTillShutdown=0, ShutdownReason=LocalizedText(Locale=None, Text=None)) | and data type: <class 'asyncua.ua.uaprotocol_auto.ServerStatusDataType'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: StatusCode(value=0) | and data type: <class 'asyncua.ua.uatypes.StatusCode'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-05-26 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2023-08-02 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-07-10 05:49:20.374000+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:04:58 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-15 10:04:59 - |WARNING| - [tb_device_mqtt.py] - tb_device_mqtt - _publish_data - 745 - Waiting for connection to be established before sending data to ThingsBoard!
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:25.098969+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:27.735187+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-15 09:05:53.603146+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)) | and data type: <class 'asyncua.ua.uaprotocol_auto.BuildInfo'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:56.989608+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: ServerStatusDataType(StartTime=datetime.datetime(2024, 8, 12, 6, 22, 56, 989608, tzinfo=datetime.timezone.utc), CurrentTime=datetime.datetime(2024, 8, 15, 9, 5, 53, 603146, tzinfo=datetime.timezone.utc), State=<ServerState.Running: 0>, BuildInfo_=BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)), SecondsTillShutdown=0, ShutdownReason=LocalizedText(Locale=None, Text=None)) | and data type: <class 'asyncua.ua.uaprotocol_auto.ServerStatusDataType'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: StatusCode(value=0) | and data type: <class 'asyncua.ua.uatypes.StatusCode'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-05-26 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2023-08-02 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:00 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-07-10 05:49:20.374000+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:25.098969+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:27.735187+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-15 09:05:55.295902+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)) | and data type: <class 'asyncua.ua.uaprotocol_auto.BuildInfo'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:56.989608+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: ServerStatusDataType(StartTime=datetime.datetime(2024, 8, 12, 6, 22, 56, 989608, tzinfo=datetime.timezone.utc), CurrentTime=datetime.datetime(2024, 8, 15, 9, 5, 55, 295902, tzinfo=datetime.timezone.utc), State=<ServerState.Running: 0>, BuildInfo_=BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)), SecondsTillShutdown=0, ShutdownReason=LocalizedText(Locale=None, Text=None)) | and data type: <class 'asyncua.ua.uaprotocol_auto.ServerStatusDataType'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: StatusCode(value=0) | and data type: <class 'asyncua.ua.uatypes.StatusCode'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-05-26 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2023-08-02 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:05:01 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-07-10 05:49:20.374000+00:00 | and data type: <class 'datetime.datetime'>
ashdam commented 3 months ago

They seem all asyncua OPCUA DataTypes isn't it?

samson0v commented 3 months ago

@ashdam try to find in logs these 3 data types: Argument, EUInformation and Range. And provide these logs.

samson0v commented 3 months ago

In logs that I added not long since I mean.

ashdam commented 3 months ago

I just got this over and over

2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:25.098969+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:27.735187+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-15 09:47:17.404002+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)) | and data type: <class 'asyncua.ua.uaprotocol_auto.BuildInfo'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:56.989608+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: ServerStatusDataType(StartTime=datetime.datetime(2024, 8, 12, 6, 22, 56, 989608, tzinfo=datetime.timezone.utc), CurrentTime=datetime.datetime(2024, 8, 15, 9, 47, 17, 404002, tzinfo=datetime.timezone.utc), State=<ServerState.Running: 0>, BuildInfo_=BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)), SecondsTillShutdown=0, ShutdownReason=LocalizedText(Locale=None, Text=None)) | and data type: <class 'asyncua.ua.uaprotocol_auto.ServerStatusDataType'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: StatusCode(value=0) | and data type: <class 'asyncua.ua.uatypes.StatusCode'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-05-26 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2023-08-02 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:23 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-07-10 05:49:20.374000+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Argument is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:24 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:25.098969+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:27.735187+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-15 09:47:19.094279+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)) | and data type: <class 'asyncua.ua.uaprotocol_auto.BuildInfo'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-08-12 06:22:56.989608+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: ServerStatusDataType(StartTime=datetime.datetime(2024, 8, 12, 6, 22, 56, 989608, tzinfo=datetime.timezone.utc), CurrentTime=datetime.datetime(2024, 8, 15, 9, 47, 19, 94279, tzinfo=datetime.timezone.utc), State=<ServerState.Running: 0>, BuildInfo_=BuildInfo(ProductUri='http://renault.com/UnifiedDataCollector/v3.1.2.0', ManufacturerName='Renault', ProductName='UnifiedDataCollector', SoftwareVersion='3.1.2.0', BuildNumber='3.1.2', BuildDate=datetime.datetime(2024, 8, 12, 6, 22, 25, 98969, tzinfo=datetime.timezone.utc)), SecondsTillShutdown=0, ShutdownReason=LocalizedText(Locale=None, Text=None)) | and data type: <class 'asyncua.ua.uaprotocol_auto.ServerStatusDataType'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: StatusCode(value=0) | and data type: <class 'asyncua.ua.uatypes.StatusCode'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-05-26 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2010-01-01 00:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2023-08-02 23:00:00+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:25 - |ERROR| - [opcua_uplink_converter.py] - opcua_uplink_converter - convert - 74 - Unsupported data: 2024-07-10 05:49:20.374000+00:00 | and data type: <class 'datetime.datetime'>
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Argument is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type EUInformation is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
2024-08-15 10:46:25 - |ERROR| - [tb_gateway_service.py] - tb_gateway_service - __send_to_storage - 1103 - Object of type Range is not JSON serializable
ashdam commented 3 months ago

@samson0v let me restart the gateway, save the full log and check. I will write back soon

ashdam commented 3 months ago

I haven't found that error message for those data types but I can search those values in OPCUA so you have data samples.

I add the full log for you to double check: high-load_ed0fe1e.log

On the other hand I found this new error

2024-08-15 10:49:34 - |ERROR| - [tb_logger.py] - tb_logger - exception - 133 - Expecting value: line 1 column 1 (char 0)
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/gateway/tb_gateway_service.py", line 1585, in __load_persistent_devices
    loaded_connected_devices = load_file(self._config_dir + CONNECTED_DEVICES_FILENAME)
                               ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/gateway/tb_gateway_service.py", line 101, in load_file
    content = load(target_file)
              ^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/simplejson/__init__.py", line 452, in load
    return loads(fp.read(),
           ^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/simplejson/__init__.py", line 514, in loads
    return _default_decoder.decode(s)
           ^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/simplejson/decoder.py", line 386, in decode
    obj, end = self.raw_decode(s)
               ^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/simplejson/decoder.py", line 416, in raw_decode
    return self.scan_once(s, idx=_w(s, idx).end())
           ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
simplejson.errors.JSONDecodeError: Expecting value: line 1 column 1 (char 0)
samson0v commented 3 months ago

@ashdam I added additional error handling to see where exactly exception raise with traceback. I hope it helps.

ashdam commented 3 months ago

@samson0v Many logs in 1442a2a

Attached log file: high-load_1442a2a.zip

ashdam commented 3 months ago

@samson0v

I found a Range example. it was ingested yesterday in our tests image

Same for Argument image

samson0v commented 3 months ago

@ashdam found the cause. Fixing...

ashdam commented 3 months ago

Just this error in 27772d2 but configuration got empty

image

image

Full log: high-load_27772d2.log

samson0v commented 3 months ago

@ashdam so the problem with converting is gone?

ashdam commented 3 months ago

Nope, because config disappeared (got empty). Let reconfigure it and test it again.

ashdam commented 3 months ago

@samson0v cannot update (reestablish) configuration it resets once I start gateway. This is the only error I got


2024-08-15 11:55:47 - |ERROR| - [opcua_connector.py] - opcua_connector - start_client - 249 - Error in main loop, trying to reconnect: %s
Traceback (most recent call last):
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 231, in start_client
    await self.__poll_nodes()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/thingsboard_gateway-3.5.1-py3.12.egg/thingsboard_gateway/connectors/opcua/opcua_connector.py", line 500, in __poll_nodes
    values = await self.__client.read_attributes(
             ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/client.py", line 915, in read_attributes
    return await self.uaclient.read_attributes(nodeids, attr)
           ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/ua_client.py", line 760, in read_attributes
    data = await self.protocol.send_request(request)
           ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/ua_client.py", line 172, in send_request
    self.check_answer(data, f" in response to {request.__class__.__name__}")
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/client/ua_client.py", line 181, in check_answer
    hdr.ServiceResult.check()
  File "/home/admin/tb-iot-gateway-latest/thingsboard-gateway/venv/lib/python3.12/site-packages/asyncua/ua/uatypes.py", line 377, in check
    raise UaStatusCodeError(self.value)
asyncua.ua.uaerrors._auto.BadNothingToDo: No processing could be done because there was nothing to do.(BadNothingToDo)
ashdam commented 3 months ago

I have deleted backup and now it seems it worked with no errors. I will check the number of messages they are getting to GCP

samson0v commented 3 months ago

@ashdam working on error BadNothingToDo and configuration cutting

samson0v commented 3 months ago

@ashdam I reproduced situtation with config cutting. In my situation config is cutting, because I have too small NETTY_MAX_PAYLOAD_SIZE, after increasing it to 1_000_000, the problem is gone.

ashdam commented 3 months ago

Regarding the suddenly missing config topic. I have this on TB server image

On the other hand telemetry rate on the GW seems good. Thank you!