Hi There,

If I try import the following templates they all bomb out by the triggers Template Ubiquiti - Nanostation Template Ubiquiti - Power Beam AC - 7.0 Template Ubiquiti - Power Beam AC - 8.0 Template Ubiquiti - Rocket AC Lite Template Ubiquiti - Rocket M

I get the following error Incorrect trigger expression. Check expression part starting from " or ({Template Ubiquiti - Power Beam AC - 8.0:ifOutOctets.5.avg(300)} > 75M)".

If I remove that trigger in question then it has the same issue with the next one.

I am using Zabbix 2.2.13

tricksol commented 8 years ago

I need to update the docs, these templates work for 2.4 and on. You can strip out the triggers and import the templates and create your own triggers.