{"wifi_sta":{"connected":true,"ssid":"***","ip":"192.168.1.71","rssi":-66},"cloud":{"enabled":false,"connected":false},"mqtt":{"connected":true},"time":"10:41","unixtime":1705142510,"serial":1765,"has_update":false,"mac":"8CAAB505BFF9","cfg_changed_cnt":0,"actions_stats":{"skipped":0},"relays":[{"ison":true,"has_timer":false,"timer_started":0,"timer_duration":0,"timer_remaining":0,"overpower":false,"is_valid":true,"source":"input"}],"emeters":[{"power":2156.20,"reactive":-850.58,"pf":-0.93,"voltage":234.31,"is_valid":true,"total":21684839.1,"total_returned":170544.0},{"power":0.00,"reactive":0.00,"pf":0.00,"voltage":234.31,"is_valid":true,"total":0.0,"total_returned":0.0}],"update":{"status":"idle","has_update":false,"new_version":"20230913-114150/v1.14.0-gcb84623","old_version":"20230913-114150/v1.14.0-gcb84623","beta_version":"20231107-164916/v1.14.1-rc1-g0617c15"},"ram_total":51064,"ram_free":35652,"fs_size":233681,"fs_free":154616,"uptime":6413}
Hello
I tried the json you provided, that worked for me.. (so the parsing seems fine the problem is the http connection.. Maybe its a problem with the authentication? Is the meter_user and the meter_password set correctly? (does the shelly even have a set password?) Is the meter ip static?
Are you familiar with postman, insomnia or curl.. if so can you provide the timeline output that reproducing the http request gives you?
No authentication on the shelly EM.
The curl works without issues:
curl http://192.168.1.71/status {"wifi_sta":{"connected":true,"ssid":"*****","ip":"192.168.1.71","rssi":-67},"cloud":{"enabled":false,"connected":false},"mqtt":{"connected":true},"time":"17:33","unixtime":1705167236,"serial":7694,"has_update":false,"mac":"8CAAB505BFF9","cfg_changed_cnt":0,"actions_stats":{"skipped":0},"relays":[{"ison":true,"has_timer":false,"timer_started":0,"timer_duration":0,"timer_remaining":0,"overpower":false,"is_valid":true,"source":"input"}],"emeters":[{"power":166.03,"reactive":-432.43,"pf":-0.36,"voltage":238.56,"is_valid":true,"total":21688167.8,"total_returned":170669.8},{"power":0.00,"reactive":0.00,"pf":0.00,"voltage":238.56,"is_valid":true,"total":0.0,"total_returned":0.0}],"update":{"status":"idle","has_update":false,"new_version":"20230913-114150/v1.14.0-gcb84623","old_version":"20230913-114150/v1.14.0-gcb84623","beta_version":"20231107-164916/v1.14.1-rc1-g0617c15"},"ram_total":51064,"ram_free":36360,"fs_size":233681,"fs_free":154616,"uptime":31138}
Hi All,
Have done a factory reset with no luck. Is there a way to retrieve the current log?
would appreciate any help troubleshooting this issue.
I am very sorry but I think I am not able to help you here.. From my tests using your provided json it works on my stick.. Only thing that comes to my mind is maybe a connection timeout?
How long does the shelly take to respond?
Have you considered to work around this issue by using the mqtt METEROVR?
that did the trick, thanks for the help :)
automation: alias: Trucki_METEROVR description: "" trigger:
I have an issue related to this, my log shows the folowing error: Http connected to meter: http://******/rpc/Shelly.GetStatus Http code OK: 200 deserializeJson() failed with code: NoMemory Http get grid meter read failed: -4 The stick is running the latest software version and has not been updated by me
log.txt created Reset reason: Software/System restart Trucki2Shelly Gateway V: 1.12 16.07.2023 06:56 { "admin_pass": "**", "mqtt_server": "192.168..", "mqtt_port": "1883", "mqtt_user": "****", "mqtt_pass": "****", "hadiscovery": "1", "device_name": "T2SGF9FC73", "meter_url": "http://192.168.1.71/status", "json_keys": "emeters,0,power", "meter_interval": "500", "meter_invert": "0", "meter_user": "admin", "meter_pass": "", "maxPower": "1400", "vbatCutoff": "500", "vbatReboot": "505", "zepc_target": "60", "zepc_average": "10", "zepc_feedback": "0", "sun2_ip": "", "sun3_ip": "", "night_maxPower": "1", "night_begin": "16:00", "night_end": "07:00", "ntpserver": "pool.ntp.org", "timezone": "WET0WEST,M3.5.0/1,M10.5.0", "darktheme": "0", "ip": "192.168.1.119", "gateway": "192.168.1.1", "subnet": "255.255.255.0", "dns": "192.168.1.1" }connected...yeey :) Wifi IP: 192.168.1.119 Wifi GW: 192.168.1.1 Wifi SN: 255.255.255.0 Wifi DNS: 192.168.1.1 RSSI: 56 % mqtt connected mqtt subscribed to T2SGF9FC73/ACSETPOINTOVR mqtt subscribed to T2SGF9FC73/DACOVR mqtt subscribed to T2SGF9FC73/CALSTEPOVR mqtt subscribed to T2SGF9FC73/METEROVR mqtt subscribed to T2SGF9FC73/MAXPOWEROVR mqtt subscribed to T2SGF9FC73/TARGETOVR Http connected to meter: http://192.168.1.71/status
HTTP GET failed. http code: -1 Http get grid meter read failed: -2