1. "Air Purifier" 開關無效

打開開關但機器面板上對應的燈並未亮起 Log:

[22:39:11][D][switch:012]: 'Air Purifier' Turning ON.
[22:39:11][D][uart_debug:114]: >>> 06:04:8D:00:01:8E 
[22:39:11][D][switch:055]: 'Air Purifier': Sending state ON 
[22:39:11][D][uart_debug:114]: <<< 06:04:FF:00:01:FC 
[22:39:11][D][uart_debug:114]: >>> 06:00:08:FF:FF:0E

[22:43:09][D][switch:016]: 'Air Purifier' Turning OFF. 
[22:43:09][D][uart_debug:114]: >>> 06:04:8D:00:00:8F 
[22:43:09][D][switch:055]: 'Air Purifier': Sending state OFF 
[22:43:09][D][uart_debug:114]: <<< 06:04:FF:00:00:FD 
[22:43:10][D][uart_debug:114]: >>> 06:00:08:FF:FF:0E

2. "Auto Air Flow" 開關無效

打開開關但機器面板上對應的燈並未亮起 Log:

[22:39:59][D][switch:012]: 'Auto Air Flow' Turning ON. 
[22:39:59][D][uart_debug:114]: >>> 06:04:88:00:01:8B 
[22:39:59][D][switch:055]: 'Auto Air Flow': Sending state ON 
[22:39:59][D][uart_debug:114]: <<< 06:04:FF:00:01:FC 
[22:39:59][D][uart_debug:114]: >>> 06:00:08:FF:FF:0E

[22:42:11][D][switch:016]: 'Auto Air Flow' Turning OFF. 
[22:42:11][D][uart_debug:114]: >>> 06:04:88:00:00:8A 
[22:42:11][D][switch:055]: 'Auto Air Flow': Sending state OFF 
[22:42:11][D][uart_debug:114]: <<< 06:04:FF:00:00:FD 
[22:42:11][D][uart_debug:114]: >>> 06:00:08:FF:FF:0E

3. light level顯示是相反的?這是否正常?

0: 最亮 1: 亮 2: 暗 3: 燈光關閉

再請蔥大撥冗查看,或有需要提供其他log再請告知,謝謝。

tsunglung commented 1 week ago

1,2 點,在 RD-360HS/G 上,都是正常 除溼機,在開機狀態,HA 打開 air purifier 或 auto air flow , 機器上的燈跟著亮。關閉,燈就關。

  1. 燈亮度(0x27) ,在 3.0 時,沒有定義,根據 service code 知道有這個 ID, 嘗試之後,知道它是控制燈亮度,有4階。至於它對應的亮度,0是最亮,或是最暗,這個只是一個定義(enum值)。