heat pump unsupported #934

Open csfolmer opened 1 year ago

csfolmer commented 1 year ago

Hi,

Why is my heat pump not supported. See also pictures of the heat pump overhere: https://github.com/tuya/tuya-home-assistant/discussions/933

See here the Tuya log: Maybe I did something wrong? or is my heat pump realy not supported??

{ "home_assistant": { "installation_type": "Home Assistant OS", "version": "2023.6.3", "dev": false, "hassio": true, "virtualenv": false, "python_version": "3.11.4", "docker": true, "arch": "aarch64", "timezone": "Europe/Amsterdam", "os_name": "Linux", "os_version": "6.1.21-v8", "supervisor": "2023.06.2", "host_os": "Home Assistant OS 10.3", "docker_version": "23.0.6", "chassis": "embedded", "run_as_root": true }, "custom_components": { "browser_mod": { "version": "2.2.2", "requirements": [] }, "sonoff": { "version": "3.5.1", "requirements": [ "pycryptodome>=3.6.6" ] }, "localtuya": { "version": "5.2.1", "requirements": [] }, "tahoma": { "version": "2.15.0", "requirements": [ "pyoverkiz==1.8.0" ] }, "hacs": { "version": "1.32.1", "requirements": [ "aiogithubapi>=22.10.1" ] } }, "integration_manifest": { "domain": "tuya", "name": "Tuya", "codeowners": [ "@Tuya", "@zlinoliver", "@frenck" ], "config_flow": true, "dependencies": [ "ffmpeg" ], "dhcp": [ { "macaddress": "105A17" }, { "macaddress": "10D561" }, { "macaddress": "1869D8" }, { "macaddress": "381F8D" }, { "macaddress": "508A06" }, { "macaddress": "68572D" }, { "macaddress": "708976" }, { "macaddress": "7CF666" }, { "macaddress": "84E342" }, { "macaddress": "D4A651" }, { "macaddress": "D81F12*" } ], "documentation": "https://www.home-assistant.io/integrations/tuya", "integration_type": "hub", "iot_class": "cloud_push", "loggers": [ "tuya_iot" ], "requirements": [ "tuya-iot-py-sdk==0.6.6" ], "is_built_in": true }, "data": { "endpoint": "https://openapi.tuyaeu.com", "auth_type": 0, "country_code": "31", "app_type": "tuyaSmart", "mqtt_connected": true, "disabled_by": null, "disabled_polling": false, "name": "zwembad pomp en verwarming", "model": "", "category": "ktkzq", "product_id": "cbu3o9ugawhn9n9z", "product_name": "Heat Pump ", "online": true, "sub": false, "time_zone": "+01:00", "active_time": "2021-08-09T13:54:25+00:00", "create_time": "2021-08-09T13:54:25+00:00", "update_time": "2023-06-24T09:51:01+00:00", "function": { "switch": { "type": "Boolean", "value": {} }, "temp_set": { "type": "Integer", "value": { "unit": "\u2103", "min": 7, "max": 60, "scale": 0, "step": 1 } }, "mode": { "type": "Enum", "value": { "range": [ "hot", "cold", "auto", "eco" ] } }, "Temp_Offset": { "type": "Integer", "value": { "unit": "\u2103", "min": 1, "max": 15, "scale": 0, "step": 1 } } }, "status_range": { "switch": { "type": "Boolean", "value": {} }, "temp_set": { "type": "Integer", "value": { "unit": "\u2103", "min": 7, "max": 60, "scale": 0, "step": 1 } }, "temp_current": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "mode": { "type": "Enum", "value": { "range": [ "hot", "cold", "auto", "eco" ] } }, "fault": { "type": "Bitmap", "value": { "label": [ "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", "11", "12", "13", "14", "15", "16", "17", "18", "19", "20", "21", "22", "23" ], "maxlen": 23 } }, "Temp_Offset": { "type": "Integer", "value": { "unit": "\u2103", "min": 1, "max": 15, "scale": 0, "step": 1 } }, "AmbientTemp": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "OCT1": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "CTT": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "ReturnAirTemp": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "WaterTankTemp": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "OCT_Cool": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "WaterInTemp": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "WaterOutTemp": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "ValveFrontTemp": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "ValvePostTemp": { "type": "Integer", "value": { "unit": "\u2103", "min": -30, "max": 150, "scale": 0, "step": 1 } }, "Compressor": { "type": "Boolean", "value": {} }, "FouValve": { "type": "Boolean", "value": {} }, "Heat": { "type": "Boolean", "value": {} }, "Fan": { "type": "Boolean", "value": {} }, "Pumb": { "type": "Boolean", "value": {} }, "ChassisHeat": { "type": "Boolean", "value": {} }, "CrankshaftHeat": { "type": "Boolean", "value": {} } }, "status": { "switch": false, "temp_set": 27, "temp_current": 21, "mode": "eco", "fault": 0, "Temp_Offset": 1, "AmbientTemp": 22, "OCT1": 22, "CTT": 22, "ReturnAirTemp": 22, "WaterTankTemp": 0, "OCT_Cool": 23, "WaterInTemp": 21, "WaterOutTemp": 21, "ValveFrontTemp": 0, "ValvePostTemp": 0, "Compressor": false, "FouValve": false, "Heat": false, "Fan": false, "Pumb": false, "ChassisHeat": false, "CrankshaftHeat": false }, "home_assistant": { "name": "zwembad pomp en verwarming", "name_by_user": null, "disabled": false, "disabled_by": null, "entities": [] } } }

csfolmer commented 11 months ago

nobody can help me?

guevara777 commented 11 months ago

Please look here => https://community.home-assistant.io/t/weau-pool-heater-pump-wvfi-010/574429/51

Maybe these guys have a solution for you.

csfolmer commented 11 months ago

Please look here => https://community.home-assistant.io/t/weau-pool-heater-pump-wvfi-010/574429/51

Maybe these guys have a solution for you.