Closed mcastrob91 closed 1 year ago
Hi @mcastrob91 there is no possibility in Ubermag to visualise the parameter in real-time. You can inspect it after the simulation has finished using micromagneticdata
and micromagnetictable
(or system.table
for the current simulation).
Note, that for energy minimisation you would need to activate saving individual steps (which in Ubermag currently comes with the restriction that it will save table data and magnetisation data after each step).
Hi,
It is possible to visualize the value of the stop parameter in the minimization driver (in real-time). I remember that in oommf this can be done by setting the Datatable.
thanks