2022-05-10 21:20:13: kai.vogl@online.de created the issue
The following unit symbols contain a period at the end of their property entries (the callibrated typo has already been pointed out in ticket #5787):\
[Amb'a'1'U] -> procedure defined amount of the major allergen of ragweed.\
[IR] -> amount of an allergen callibrated through in-vivo testing using the Stallergenes® method.\
Additionally, there is a question of coherence regarding the property of "Stilb"(sb). It seems to be the only property that makes use of an abbreviation (lum. intensity density).
Issue migrated from trac ticket # 5805
component: unit definitions | priority: trivial
2022-05-10 21:20:13: kai.vogl@online.de created the issue