Closed Andrew-S-Rosen closed 1 year ago
hi @arosen93 good question indeed. ISYM=0 is required for systems that switch from higher to lower symmetry during the calculation (for instance some cases in NEB), but for others (e.g. a normal relaxation) it may be quite safe to use default symmetry tags. The setting can be overwritten but the user should do some tests to double-check. The reasoning behind this can be found in https://github.com/ulissigroup/vasp-interactive/issues/17
Thanks! That makes sense. Sometimes ISYM=0 is valuable for static bandstructure calculations, so it's nice that it can be set off by the user (although I also like setting it off by default!). Looking forward to seeing if/when vasp-interactive
is compatible with VASP 6.4.1+!
Very cool project! I'm definitely going to try this out sometime.
In the README, it says
Is that always forced to be the case or just the default? It'd be nice if I could set ISYM != 0, e.g., for a static calculation. Mostly just curious.