Open DavidCussans opened 7 months ago
3A fuse in place (taken from 065 design). 100mA will be a fast fuse unfortunately, component will be added once I have found a part number.
SF-0603FP015F-2 will used on 3V3 line, it is a 150mA fast fuse - hopefully has enough head room to compensate for in rush at power on. 100mA was originally requested but not available in slow-blow as an 0603.
Done.
Schematic looks good.
Fermilab electrical safety reportedly insist on fuses at power input to boards. This isn't usually done on uTCA boards, but add fuses to make life easier for ourselves
Normal operating power for MIB ~ 12W ( i.e. 1A from 12V )
Put in 3A slow-blow surface mount fuse for VP12 Put in 100mA slow-blow SMD fuse for MP3V3