usnistgov / REFPROP-issues

A repository solely used for reporting issues with NIST REFPROP
26 stars 13 forks source link

REFPROP10: PHFLSH error 16 for a specific case of WATER #143

Closed imanlas closed 5 years ago

imanlas commented 5 years ago

Hi,

We got an unexpected error (PHFLSH error 16) in calculating a specific case using REFPROP10 interface:

Fluid: WATER Pressure: 34 bara Enthalpy: 354.45 kJ/kg (Use the default reference state)

The same case can be calculated without a problem using (Pressure, Temperature), (Pressure, Int. Energy), (Pressure, Entropy), (Pressure, Density) and ... as inputs.

Here I have attached the snapshot:

refprop_bug .

EricLemmon commented 5 years ago

This bug has now been fixed, if you would like an updated DLL, please contact us directly (eric.lemmon@nist.gov)

RogersCory commented 3 years ago

@EricLemmon I think I have found this bug again. I am using DLL version number 10.0.

image

ianhbell commented 3 years ago

The bug was fixed in one of the beta releases, so you'll need that. Email me ian.bell@nist.gov for the download