Open gytisgreitai opened 2 years ago
@v-s-c-o-p-e can you tell me if you are connecting to CN-NMODE or to CN-REMOTE2? Thanks!
check out this project. here you find a pcb, wiring diagrams and code to communicate with the heatpump.
https://github.com/pemue-git/pcb/tree/master/WH-MDC05F3E5_comm
Oh wow, thanks! this is really great. And you used the same to communicate via esp?
no i havent implemented it myself. but here is the code to communicate with the heat pump. i think you could port the code to esp/mycropython without much effort. https://github.com/der-lolo/aquarea/blob/master/FHEM/67_Aquarea.pm
Hi, can you explain how you wired this? From the code I see the pins you used, but can you explain more on this one: "4 port bi-directional LogicLevel converter." is it because your board is not 5v tolerant? Thanks!