valentinedwv / ioostech

Automatically exported from code.google.com/p/ioostech
0 stars 0 forks source link

Keep swe vector localFrame names generic #57

Closed GoogleCodeExporter closed 8 years ago

GoogleCodeExporter commented 8 years ago
This is a very small tweak, but I'd like to request that we keep localFrame 
names generic and ignore things like feature type. Currently in the 
timeSeriesProfile SWE example, the sensors' localFrame includes profile 
(#wmo_41001_sensor1_profile_frame):

https://code.google.com/p/ioostech/source/browse/trunk/templates/Milestone1.0/SW
E-SingleStation-TimeSeriesProfile.xml#159

Since the sensor's local frame is relevant to all feature types, I'd like it to 
just be #wmo_41001_sensor1_frame. Then it's consistent across feature types, 
and it matches the station local frame format also (#{asset_short_id}_frame).

Anyone see an issue with this? Fixing and closing tomorrow Wednesday June 5 at 
COB.

Original issue reported on code.google.com by sh...@axiomalaska.com on 4 Jun 2013 at 11:45

GoogleCodeExporter commented 8 years ago
Fixed and changed in m1.0 templates.

https://code.google.com/p/ioostech/source/browse/trunk/templates/Milestone1.0/SW
E-SingleStation-TimeSeriesProfile.xml#158
https://code.google.com/p/ioostech/source/browse/trunk/templates/Milestone1.0/SW
E-SingleStation-TimeSeriesProfile_QC.xml#176

Original comment by sh...@axiomalaska.com on 5 Jun 2013 at 8:05