double counting water effects with premelt method(s) #96

Closed chrishavlin closed 5 months ago

chrishavlin commented 5 months ago

in the pre-melting method, the effect of water is accounted for in the depressed solidus, so when using HK03 with pre-melt method the water content should not be used. Should add a CH2O = 0 in the spot where it calculations the melt-free viscosity.