velzend / create_ikohs_fan

Create (IKOHS) Windcalm DC convert white ceiling fan (with remote and wireless)
61 stars 0 forks source link

Key 64 is timer #13

Open bonjour81 opened 1 year ago

bonjour81 commented 1 year ago

Hello,

No sure how to contact you so I open an issue.

In readme it is stated key 64 is unknown.

As far as I can see, it follow timer function in minute.

If timer is set to 1h, key 64 become 60 If timer is set to 2h, key 64 become 120 etc...

but it seems to stay stuck (no countdown of remaining time, as far as I can see).

Best regards,

bonjour81 commented 1 year ago

Also a hint for the beep "disabling", if you don't want to remove (unsolder) the buzzer.

-Some adhesive tape on the buzzer -Some glue or silicone in the hole of the buzzer -both

Can make the beep less loud to barely hearable in a quiet night.

Take care the glue trick may be difficult to reverse and the beep may be useful if you need to reset the device.

bonjour81 commented 1 year ago

For the record, I also notice that on my fan, the dps 23 (lamp temperature), does not work are document, but just toggle each time a value is sent. For example, I can sent 3 time the same value 500, it will toggle between the 3 temperatures (same as the single button on the remote control).