Closed Donder24 closed 8 months ago
It this diagnostics file from the moment the pellets were depleted? It seems that pellets depleted is not implemented as an alarm. Does the stove app show an alarm? I do see a register that might be the one we need, but that also indicates that the pellets are ok.
config_entry-aguaiot-ff6449b5b8ca4a3f878103b86ee1f0d7.json
Yes (this is indeed when the alarm was active) and yes the app shows this alarm also.
I have another diagnostics file also from this moment.
Can you also send a debug file when the pellet container is full? And this alarm is triggered before the container is completely empty?
config_entry-aguaiot-ff6449b5b8ca4a3f878103b86ee1f0d7-2.json
Sure, in this file the tank is full. yes there´s a sensor at a certain height and when it doesn´t detect pellets anymore, you´ve got 30min to refill. Else the stove stops working.
Please try v0.2.6-beta1
I´ve updated the integration but it might take a few days before the alarm becomes active again since I just poured in a whole bag... Keep you posted!
You should already see the new sensor. Let me know if it works like expected when the stove is empty :)
You´re the best! 🥇
Works like expected! Great job! If you´re dutch speaking, the result:
Hi,
just tested the " pellets depleted " because my stove ran out off pellets, but the alarm isn't displayed. State says : "Working" Alarm says: "no AL"
Does anybody know where I can find this?
config_entry-aguaiot-ff6449b5b8ca4a3f878103b86ee1f0d7-1.json