Switch warning on startup : setting switch by switch is not possible #151

Closed GoogleCodeExporter closed 8 years ago

GoogleCodeExporter commented 8 years ago
In Model/Setup menu, modifying the list of switches to be verified at startup 
(TRE0AG by deflauft) is not allowed.

Verified on 1482 (my radio) and 1548 (by SIMU).

Original issue reported on code.google.com by f.ague...@wanadoo.fr on 2 Nov 2012 at 6:52

GoogleCodeExporter commented 8 years ago
[deleted comment]
GoogleCodeExporter commented 8 years ago
Did you press [MENU Long]?

Original comment by bson...@gmail.com on 2 Nov 2012 at 8:05

GoogleCodeExporter commented 8 years ago
Yes, but it doesn't work :-(

Original comment by f.ague...@wanadoo.fr on 2 Nov 2012 at 8:11

GoogleCodeExporter commented 8 years ago
Other sequences are working? only TRE0AG not working?

Original comment by bson...@gmail.com on 2 Nov 2012 at 8:16

GoogleCodeExporter commented 8 years ago
which options for the simu? It works here :(

Original comment by bson...@gmail.com on 2 Nov 2012 at 8:32

GoogleCodeExporter commented 8 years ago
common options between my radio and SIMU = FRSKY, AUTOSWITCH, FLIGHTPHASES, 
DBLKEYS, PPMCA, PPMSYMLIM, CURVES, xCURVES, GVARS

Original comment by f.ague...@wanadoo.fr on 2 Nov 2012 at 8:46

GoogleCodeExporter commented 8 years ago
I don't have acces to any sequence except TRE0AG.

Original comment by f.ague...@wanadoo.fr on 2 Nov 2012 at 8:49

GoogleCodeExporter commented 8 years ago
Sorry Bertrand, it was a false alarm :-(

I've found the "problem" : I thought that editing TRE0AG was like RETA123 for 
beep control, and I understand my mistake while reading the english manual. So, 
ok now, [menu long] to record switches state...
I will add this procedure in the french manual.