BSravanthi commented 7 years ago

Defect Description: The Simulation page of "Demonstration of Solvent Effects on Fluorescence Spectra of a Fluorophore" experiment of this lab, when we switch on the Spectrophotometer, the light are blinking, ie functionality of the meter has started with out preparing the solution. As per the process once the solution is ready then the functionality of the meter should start. Need to fix the issue in order to maintain the functionality of the experiment.

Actual Result : The Simulation page of "Demonstration of Solvent Effects on Fluorescence Spectra of a Fluorophore" experiment of this lab, when we switch on the Spectrophotometer, the light are blinking, ie functionality of the meter has started with out preparing the solution. As per the process once the solution is ready then the functionality of the meter should start.

Environment : OS: Windows 7, Ubuntu-16.04,Centos-6 Browsers: Firefox-42.0,Chrome-47.0,chromium-45.0 Bandwidth : 100Mbps Hardware Configuration:8GBRAM , Processor:i5

Test Step Link: https://github.com/Virtual-Labs/molecular-florescence-spectroscopy-responsive-lab-iiith/blob/master/test-cases/integration_test-cases/Demonstration-of-Solvent-Effects-on-Fluorescence-Spectra-of-a-Fluorophore/Demonstration-of-Solvent-Effects-on-Fluorescence-Spectra-of-a-Fluorophore_17_Spectrophotometer_p1.org

Attachment: qa_mfs_i93

sadhanareddy commented 7 years ago

Issue is fixed now. Spectofluorimeter runs only for the one time as per the functionality of the experiment i.e; when the soultion is prepared.

BSravanthi commented 7 years ago

Closed #96