Save the last selected OBP60 page for a restart after power down #29

Closed norbert-walter closed 2 years ago

norbert-walter commented 2 years ago

Save the last selected OBP60 page for a restart after power down. The MFD starts then with the old last page.

wellenvogel commented 2 years ago

This has to be done in the OBP60 code.

norbert-walter commented 2 years ago

preferences.begin("obp", false); // Open nonvolatile storage (nvs) NodeAddress = preferences.getInt("LastNodeAddress", 32); // Read stored last NodeAddress, default 32 preferences.end();