Remove this text-
A new lineup of optional IP interfaces allows expanded system operations. These include: the N-8000AL Analog Phone Interface, which allows any standard analog phone to be used as a master station. The N-8000AF Audio Interface provides audio signal connections to paging amps, playback sources, recording devices and schedule clocks. It also incorporates a built-in bell scheduler and tone library for classroom change signals. Up to 16 different schedules of 64 events each may be programmed. The N-8000CO Outside Line Interface provides access to an outside telephone line for dial-in calling, paging and control, as well as outbound forwarding of calls made to master stations. Lastly, the N-8000DI Direct Interface provides contact ins & Outs for control of paging amps, door/gate access, CCTV camera call-up & LED status panels. It may accessed by standard controls or dialing commands from any master station on the network.
Also see the NX-100 Network Audio.
Note: Running the N-8000 Software requires Microsoft .NET Framework 3.5 SP1 and Microsoft SQL Server 2005 Express. Please be sure to download and install both programs for full software functionality. When using software version 3.00 or 2.02, all N-8000 devices on the network must have firmware version 2.0 or higher. Instructions for updating the firmware are located in the N-8000 system manual under: "System Settings Using the Browser: System Management: Updating Firmware."
Software v1.41
For customers continuing to use original N-8000 products only and who do not require any new features or functionality, you may update the firmware in your components to v1.41. This includes the following N-8000 models: N-8000EX, N-8010EX, N-8000MI, & Q-8540WP. Please note- ALL system components need to be updated to the same version firmware to ensure reliable operation. The firmware for your product(s) can be found on the TOA Data Library by clicking on the following link: http://www.toa-products.com/international/. Just enter the model number and follow the appropriate link (for U.S. models please use the "CU" version download)". Then click on the Software (firmware) link to download."
Note: Components with 1.41 or earlier firmware will not work with GUI software v2.00 or later.
Replace with this text-
The N-8000AF provides either an analog audio input/output bridge to the N-8000 system, a bell schedule generator with internal tones, or record functionality for archival purposes. It can also function as the system master clock, with sync to contact closure or NTP server as required. When used as an analog audio bridge to the N-8000 intercom system, it accepts one mic or line level input which can be broadcast to any paging zone or station on the system. One line-level output is provided, with eight contact closure inputs and eight contact closure outputs. Contact closures may be synchronized with a paging event. When used as a bell schedule generator, the N-8000AF provides 16 schedules with 64 events per schedule. Five internal tones are available, with the option to trigger up to four external paging sources. When used as for recording it provides an analog audio output and contact closure control for external recording devices to record pages, announcements, and conversations.
Remove this text- A new lineup of optional IP interfaces allows expanded system operations. These include: the N-8000AL Analog Phone Interface, which allows any standard analog phone to be used as a master station. The N-8000AF Audio Interface provides audio signal connections to paging amps, playback sources, recording devices and schedule clocks. It also incorporates a built-in bell scheduler and tone library for classroom change signals. Up to 16 different schedules of 64 events each may be programmed. The N-8000CO Outside Line Interface provides access to an outside telephone line for dial-in calling, paging and control, as well as outbound forwarding of calls made to master stations. Lastly, the N-8000DI Direct Interface provides contact ins & Outs for control of paging amps, door/gate access, CCTV camera call-up & LED status panels. It may accessed by standard controls or dialing commands from any master station on the network.
Also see the NX-100 Network Audio.
Note: Running the N-8000 Software requires Microsoft .NET Framework 3.5 SP1 and Microsoft SQL Server 2005 Express. Please be sure to download and install both programs for full software functionality. When using software version 3.00 or 2.02, all N-8000 devices on the network must have firmware version 2.0 or higher. Instructions for updating the firmware are located in the N-8000 system manual under: "System Settings Using the Browser: System Management: Updating Firmware."
Software v1.41
For customers continuing to use original N-8000 products only and who do not require any new features or functionality, you may update the firmware in your components to v1.41. This includes the following N-8000 models: N-8000EX, N-8010EX, N-8000MI, & Q-8540WP. Please note- ALL system components need to be updated to the same version firmware to ensure reliable operation. The firmware for your product(s) can be found on the TOA Data Library by clicking on the following link: http://www.toa-products.com/international/. Just enter the model number and follow the appropriate link (for U.S. models please use the "CU" version download)". Then click on the Software (firmware) link to download."
Note: Components with 1.41 or earlier firmware will not work with GUI software v2.00 or later.
Replace with this text- The N-8000AF provides either an analog audio input/output bridge to the N-8000 system, a bell schedule generator with internal tones, or record functionality for archival purposes. It can also function as the system master clock, with sync to contact closure or NTP server as required. When used as an analog audio bridge to the N-8000 intercom system, it accepts one mic or line level input which can be broadcast to any paging zone or station on the system. One line-level output is provided, with eight contact closure inputs and eight contact closure outputs. Contact closures may be synchronized with a paging event. When used as a bell schedule generator, the N-8000AF provides 16 schedules with 64 events per schedule. Five internal tones are available, with the option to trigger up to four external paging sources. When used as for recording it provides an analog audio output and contact closure control for external recording devices to record pages, announcements, and conversations.